Permit Details

Permit Search

Permit

New Residential Construction

486 SW MEADOW WOOD GLN
LAKE CITY, FL 32024

Permit #
000041626
Application #
48802
Status Completed
  1. Submitted Nov 4, 2021
  2. Issued Mar 30, 2021
  3. Expires May 3, 2022
  4. Completed Nov 4, 2021

Property

Parcel #
00276-109
Owner
Matukaitis, Charles J & Beth A
Acres
5.01
Subdivision
Meadow Wood
Zoning
A-3
Flood zone
X
District
2

Permit

Status
Completed
Septic release
Released
Related permit
—

Job Details

Elevation regulation
Subdivision Plat
Finished floor requirement
THE HIGHER OF: ELEVATION 163' OR 8" ABOVE THE HIGHEST ADJACENT GRADE
Requirement needed
By Nailing Inspection
Document needed is
a Surveyor letter giving the Finished Floor Elevation
Document receieved
Yes
Fema map number
12023C0270C
In floodway
N
This is the construction of a
Single Family Dwelling
Setbacks Front
30
Setback Side 1
25
Setback Side 2
25
Setbacks Rear
25
Stories
1
Heated Area (Sqft)
1783
Total Area (Sqft)
2740
Building Height
20
Building Code Construction Type
V
Building Code Element
B
Building Code Occupancy Types
Residential
Occupancy Use Title
single family
Building Code Edition
2020 Florida Building Code 7th Edition and 2017 National Electrical Code
Septic# (00-0000) or (X00-000)
21-0277

Status & Review History

  1. Point Review - Received-Hard Copy Application
  2. Zoning Review - Reviewed
  3. Plan Review - Reviewed
  4. Zoning Review - Reviewed
  5. Final Review - Payment Needed
  6. Permit Issued
  7. Final Review - Payment Needed

Contractors

  • Douglas Edgley

    Cee-bas Incorporated Dba Edgley Construction Company

    License
    CRC1330689
    Title
    Residential Contractor
    Role
    Contractor

    County License & State License & Liability Insurance & Workers Comp & Employees Workers Comp Expired.

  • Matthew H Burns

    Burns Electrical Services Inc

    License
    EC13006531
    Title
    Electrical Contractor
    Role
    Subcontractor

    Workers Comp Expired.

  • David E Hall

    David Hall's Air Cond & Heating Svc,inc.

    License
    CAC057424
    Title
    Class B A/c Contractor
    Role
    Subcontractor

    Workers Comp Expired.

  • Don C Bills Sr

    Hometown Plumbing Services Llc

    License
    CFC1428890
    Title
    Plumbing Contractor
    Role
    Subcontractor
  • Darin L Summerlin

    Summerlin Roofing Inc

    License
    CCC1326192
    Title
    Roofing Contractor
    Role
    Subcontractor

Inspections

  1. Apr 5, 2021

    Passed: Electrical - Temporary Service

    Inspected by Matt Forsyth

  2. Apr 5, 2021

    Release to power company

    Inspected by Matt Forsyth

  3. Apr 6, 2021

    Release to power company

    Changed Power Company To Fpl And Resent.

    Inspected by Laurie Hodson

  4. Apr 28, 2021

    Passed: Building - Footer

    Inspected by Matt Forsyth

  5. Apr 28, 2021

    Passed: Engineering - Setbacks

    Inspected by Matt Forsyth

  6. May 12, 2021

    Passed: Plumbing/Gas - 1st Underground Rough–In

    Inspected by Matt Forsyth

  7. May 24, 2021

    Passed: Building - Slab

    Welded Wire Mesh Needs To Sit On Chairs

    Inspected by Matt Forsyth

  8. Jun 21, 2021

    Passed: Building - Ext Strapping/Wall Sheathing

    Building Was Inspected For Wall Sheeting Only

    Inspected by Matt Forsyth

  9. Jul 20, 2021

    Passed: Building - Framing

    Inspected by Matt Forsyth

  10. Aug 2, 2021

    Passed: Mechanical - Rough In

    Inspected by Matt Forsyth

  11. Aug 2, 2021

    Passed: Plumbing/Gas - 2nd Rough-In

    Inspected by Matt Forsyth

  12. Aug 2, 2021

    Passed: Electrical - 1st Underground Rough–In

    Inspected by Matt Forsyth

  13. Aug 20, 2021

    Passed: Building - Insulation

    Walls Only

    Inspected by Matt Forsyth

  14. Sep 23, 2021

    Septic Release Inspection

    Inspected by Health Dept

  15. Sep 29, 2021

    Passed: Electrical - Permanent Power

    Need Driveway Release

    Inspected by Matt Forsyth

  16. Oct 1, 2021

    Release to power company

    Driveway Final Received...

    Inspected by Matt Forsyth

  17. Nov 4, 2021

    Passed: Building - Final

    Inspected by Matt Forsyth

Documents