Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

New Residential Construction Permit
Address 403 SW OAK WAY
LAKE CITY, FL 32025
Parcel #: 09116-124
Acres: 5.01
Owner: David And Martha Calverley
Subdivision: Hills At Rose Creek Phase 1
Zoning: PRRD
Flood Zone: X
District: 4
Application #: 48051
Permit #: 000041364
Related Permit: Culvert: 000041363
Submitted: Tuesday, December 29, 2020
Issued: Friday, February 19, 2021
Expires: Wednesday, December 1, 2021
Completed: Wednesday, December 1, 2021
Status: Completed
Septic Release? Yes
Notes:
WATER RUNOFF NATRUALLY FLOWS TO THIS LOT. EROSION CONTROL WILL BE NECESSARY, CONTRACTOR STATES SURVEYER WILL CONFIRM ALL SETBACKS INCLUDING WETLAND SETBACKS.
Job Details
This is the construction of a Single Family Dwelling
Heated Area (Sqft) 2315
Total Area (Sqft) 4305
Stories 2
Building Height 22
Building Code Construction Type V
Building Code Element B
Building Code Occupancy Types Residential
Occupancy Use Title single family dwelling
Setbacks Front 30
Setback Side 1 25
Setback Side 2 25
Setbacks Rear 25
Septic# (00-0000) or (X00-000) 21-0019
Building Code Edition Florida Building Code 2017 6th Edition & 2014 National Electrical Code
Elevation regulation Minimum Requirement
Finished floor requirement One foot above the road
Fema map number 12023C0384D
In floodway N
Review Notes
12/29/2020 Application pending.
12/30/2020 Point Review - Printed-Online Application
12/30/2020 Point Review - Reviewed
1/25/2021 Plan Review - Documents Required NEEDED: EH, PAGE 2 OF SEALED STRUCTURAL
2/3/2021 Zoning Review - Corrections Needed NEEDED: PAGE 2 OF SEALED STRUCTURAL WETLAND ON THE LOT - PER THE SITE PLAN THE HOME IS NOT 35' AWAY FROM THE WETLAND. NEED TO REDO THE SITE PLAN OR HAVE A SURVEYOR SHOW THE WETLANDS AND THE 35' BUFFER ZONE AND THE HOME LOCATION ON A MAP.
2/16/2021 Plan Review - Documents Required STILL MISSING SHEET S-2 2-16-21 T.C. WETLAND ON THE LOT - PER THE SITE PLAN THE HOME IS NOT 35' AWAY FROM THE WETLAND. NEED TO REDO THE SITE PLAN OR HAVE A SURVEYOR SHOW THE WETLANDS AND THE 35' BUFFER ZONE AND THE HOME LOCATION ON A MAP.
2/16/2021 Plan Review - Reviewed STILL MISSING SHEET S-2 2-16-21 T.C. RECEIVED 2-16-21, STILL NEED NEW SITE PLAN WETLAND ON THE LOT - PER THE SITE PLAN THE HOME IS NOT 35' AWAY FROM THE WETLAND. NEED TO REDO THE SITE PLAN OR HAVE A SURVEYOR SHOW THE WETLANDS AND THE 35' BUFFER ZONE AND THE HOME LOCATION ON A MAP.
2/19/2021 Zoning Review - Corrections Needed STILL MISSING SHEET S-2 2-16-21 T.C. RECEIVED 2-16-21 STILL NEED NEW SITE PLAN - 2-19-21 WETLAND ON THE LOT - PER THE SITE PLAN THE HOME IS NOT 35' AWAY FROM THE WETLAND. NEED TO REDO THE SITE PLAN OR HAVE A SURVEYOR SHOW THE WETLANDS AND THE 35' BUFFER ZONE AND THE HOME LOCATION ON A MAP.
2/19/2021 Zoning Review - Reviewed STILL MISSING SHEET S-2 2-16-21 T.C. RECEIVED 2-16-21 NEW SITE PLAN received - 2-19-21 WETLAND ON THE LOT - PER THE SITE PLAN THE HOME IS NOT 35' AWAY FROM THE WETLAND. NEED TO REDO THE SITE PLAN OR HAVE A SURVEYOR SHOW THE WETLANDS AND THE 35' BUFFER ZONE AND THE HOME LOCATION ON A MAP.
2/19/2021 Final Review - Reviewed STILL MISSING SHEET S-2 2-16-21 T.C. RECEIVED 2-16-21 STILL NEED NEW SITE PLAN - 2-19-21 WETLAND ON THE LOT - PER THE SITE PLAN THE HOME IS NOT 35' AWAY FROM THE WETLAND. NEED TO REDO THE SITE PLAN OR HAVE A SURVEYOR SHOW THE WETLANDS AND THE 35' BUFFER ZONE AND THE HOME LOCATION ON A MAP.
2/19/2021 Final Review - Payment Needed STILL MISSING SHEET S-2 2-16-21 T.C. RECEIVED 2-16-21 STILL NEED NEW SITE PLAN - 2-19-21 WETLAND ON THE LOT - PER THE SITE PLAN THE HOME IS NOT 35' AWAY FROM THE WETLAND. NEED TO REDO THE SITE PLAN OR HAVE A SURVEYOR SHOW THE WETLANDS AND THE 35' BUFFER ZONE AND THE HOME LOCATION ON A MAP.
2/19/2021 Permit Issued Permit #000041364 created and approved.
11/16/2021 Final Review - Payment Needed STILL MISSING SHEET S-2 2-16-21 T.C. RECEIVED 2-16-21 STILL NEED NEW SITE PLAN - 2-19-21 WETLAND ON THE LOT - PER THE SITE PLAN THE HOME IS NOT 35' AWAY FROM THE WETLAND. NEED TO REDO THE SITE PLAN OR HAVE A SURVEYOR SHOW THE WETLANDS AND THE 35' BUFFER ZONE AND THE HOME LOCATION ON A MAP.
Contractors
Name/ Business License Title Role
Isaiah Cully
Ic Construction Llc
CBC1259655 Building Contractor Contractor
Cody Barrs
Barrs Plumbing Inc
CFC1427145 Plumbing Contractor Subcontractor
Tyler M Turner
Tmt Roofing Llc
CCC1330410 Cert Roofing Subcontractor
Clinton G Wilson
Wilson Heat & Air Inc
CAC057886 Class B A/c Subcontractor
Everton D Ruddock
D&s Lighting Inc
EC13003800 Electrical Contractor Subcontractor
Inspections
Inspection Notes Performed By Date
Passed: Engineering - Initial Driveway Mccormick, David 2/22/2021
Passed: Engineering - Setbacks Need To Be Confirmed By Surveyor Troy Crews 4/6/2021
Passed: Building - Footer Footer Ok Need To Confirm Wetland Setback With Surveyor Prior To Pour Troy Crews 4/6/2021
Cancelled: Building - Framing Anthony Aslan 5/7/2021
Cancelled: Mechanical - Rough In Anthony Aslan 5/7/2021
Passed: Plumbing/Gas - 1st Underground Rough–In Troy Crews 5/18/2021
Passed: Electrical - Temporary Service Troy Crews 5/18/2021
Release to power company Troy Crews 5/18/2021
Passed: Building - Slab Troy Crews 5/21/2021
Passed: Building - Roof Decking Troy Crews 7/1/2021
Passed: Building - Wall Sheathing Porch Post Already Strapped Troy Crews 7/1/2021
Passed: Building - Framing Troy Crews 8/19/2021
Passed: Electrical - 2nd Rough-In Troy Crews 8/19/2021
Failed: Mechanical - Rough In Fireplace Duct Not Complete Troy Crews 8/19/2021
Passed: Plumbing/Gas - 2nd Rough-In Troy Crews 8/19/2021
Septic Release Inspection Health Dept 8/27/2021
Passed: Mechanical - Rough In Make Sure Straps Get Screwed Down On Fireplace Duct Troy Crews 8/27/2021
Passed: Building - Insulation Troy Crews 8/27/2021
Passed: Engineering - Final Driveway Jones, Richard 10/28/2021
Passed: Electrical - Permanent Power Troy Crews 11/16/2021
Release to power company Troy Crews 11/16/2021
Cancelled: Building - Final Troy Crews 11/23/2021
Passed: Building - Final Troy Crews 11/30/2021
Documents
File Name Date File Size
Approved Truss Plans 48051 2021-01-25 07.51.46.605.pdf 2023.12.26 1.04MB
Sealed S1 2021-02-16 11.39.12.699.pdf 2023.12.26 946.49kB
Sub Vf Form.pdf 2023.12.26 2.24MB
Power Release-electrical-permanent Power 20211116.pdf 2023.12.26 39.05kB
Calverly - Updated Site Plan 4-14-21.pdf 2023.12.26 92.33kB
911 Address Form 20201229 163249.pdf 2023.12.26 83.43kB
Property Appraiser Parcel Details Printed Page 20201229 163517.pdf 2023.12.26 787.93kB
Surveyor Letter Giving The Finished Floor Elevation 2021-11-15 11.51.35.523.pdf 2023.12.26 337.26kB
Structural Engineering And Wind Load Calculations 20210212 113946.pdf 2023.12.26 998.77kB
Owner And Contractor Signature Page 20201229 161503.pdf 2023.12.26 1.11MB
Manual J Forms 20201229 163252.pdf 2023.12.26 190.93kB
Sealed S1 (supposed To Be S2).pdf 2023.12.26 998.77kB
Sealed S3.pdf 2023.12.26 1.57MB
Blower Door 41364 2021-12-01 07.20.03.518.jpg 2023.12.26 2.31MB
Lidar 48051 2021-02-19 15.05.01.517.pdf 2023.12.26 97.30kB
Power Release-electrical-temporary Service 20210518.pdf 2023.12.26 38.92kB
Calverley Eh 2021-02-03 08.52.09.455.pdf 2023.12.26 523.28kB
Site Plan 20210219 031645.pdf 2023.12.26 245.84kB
Original Permit 20210219.pdf 2023.12.26 42.82kB
Calverley Truss Engineering 2020-12-30 10.35.05.999.pdf 2023.12.26 917.50kB
Win_20210521_16_24_30_pro 2021-05-21 16.26.01.985.jpg 2023.12.26 182.23kB
Certificate Of Occupancy 20211201.pdf 2023.12.26 54.57kB
Energy Code Forms 20201229 163251.pdf 2023.12.26 161.16kB
Hills_at_rose_creek_phs1 Lot 24 2021-02-03 16.45.47.764.pdf 2023.12.26 1,016.50kB
Other 20210212 113829.pdf 2023.12.26 998.77kB
Residential Or Commercial Checklist 20201229 163252.pdf 2023.12.26 821.17kB
Product Approval Code Specifications Form 20201229 163252.pdf 2023.12.26 748.01kB
Sealed S4.pdf 2023.12.26 710.14kB
Architectural Plans 20201229 163249.pdf 2023.12.26 1.63MB
Recorded Notice Of Commencement 20210401 115410.pdf 2023.12.26 1.07MB