Inspection |
Notes |
Performed By |
Date |
Passed: Building - Footer |
|
Troy Crews |
3/12/2021 |
Passed: Engineering - Setbacks |
|
Troy Crews |
3/12/2021 |
Passed: Plumbing/Gas - 1st Underground Rough–In |
Waste Only |
Troy Crews |
4/12/2021 |
Passed: Building - Slab |
Need Ticket For Termite Spray |
Troy Crews |
4/27/2021 |
Passed: Building - Wall Sheathing |
|
Troy Crews |
6/3/2021 |
Passed: Building - Roof Decking |
|
Troy Crews |
6/3/2021 |
Failed: Building - Framing |
T12truss Calling For 1936 Uplift Mid Span Missing |
Matt Forsyth |
6/23/2021 |
Passed: Electrical - 2nd Rough-In |
|
Matt Forsyth |
6/23/2021 |
Failed: Mechanical - Rough In |
No Work Done |
Matt Forsyth |
6/23/2021 |
Passed: Building - Framing |
|
Matt Forsyth |
7/21/2021 |
Cancelled: Electrical - 2nd Rough-In |
|
Matt Forsyth |
7/21/2021 |
Failed: Mechanical - Rough In |
Duck Work Coming Through Ceiling For Plentem Needs 3" Clearance. All Hv Ac Boots In Ceiling Need Gasket |
Matt Forsyth |
7/21/2021 |
Failed: Plumbing/Gas - 2nd Rough-In |
Work Not Complete |
Matt Forsyth |
7/21/2021 |
Cancelled: Electrical - 2nd Rough-In |
|
Troy Crews |
8/16/2021 |
Failed: Building - Insulation |
Spot Loose In Garage, Back Wall Water Line Added Needs Nail Plate And Also Displaced Insulation |
Troy Crews |
8/17/2021 |
Failed: Mechanical - Rough In |
Return Registers Dont Have Seals, Also Oven Duct Must Have Smooth Interior, Dont Sheetrock Until Re Inspected |
Troy Crews |
8/17/2021 |
Failed: Plumbing/Gas - 2nd Rough-In |
Nail Plate Needed On Water Line Added Rear Wall |
Troy Crews |
8/17/2021 |
Passed: Plumbing/Gas - 2nd Rough-In |
|
Troy Crews |
8/23/2021 |
Failed: Building - Insulation |
Fallen Out Several Spots |
Troy Crews |
8/24/2021 |
Failed: Mechanical - Rough In |
Oven Duct Not Replaced |
Troy Crews |
8/24/2021 |
Failed: Building - Insulation |
Spot Still Missing At Rear Wall At Hose Bib |
Troy Crews |
8/26/2021 |
Failed: Mechanical - Rough In |
No Duct For Oven Hood |
Troy Crews |
8/26/2021 |
Passed: Building - Insulation |
|
Troy Crews |
8/27/2021 |
Passed: Mechanical - Rough In |
Oven Hood Eliminated Look For Ventless Hood At Final |
Troy Crews |
8/27/2021 |
Passed: Electrical - Permanent Power |
|
Troy Crews |
10/13/2021 |
Release to power company |
|
Troy Crews |
10/13/2021 |
Certificate-Release Certificate |
Insulation Verified |
Troy Crews |
12/9/2021 |
Passed: Building - Final |
Need Pictures Of Attic Insulation |
Troy Crews |
12/9/2021 |