Permit Details

Permit Search

Permit

New Residential Construction

239 SW FIELDSTONE CT
LAKE CITY, FL 32024

Permit #
000040379
Application #
46801
Status Completed
  1. Submitted Oct 14, 2021
  2. Issued Aug 18, 2020
  3. Expires Apr 19, 2023
  4. Completed Oct 21, 2022

Property

Parcel #
02438-149
Owner
James & Lora David
Acres
0.50
Subdivision
Emerald Cove Phase 2
Zoning
RSF-2
Flood zone
X
District
3

Permit

Status
Completed
Septic release
Released
Related permit
—

Job Details

Elevation regulation
Subdivision Plat
Finished floor requirement
135.00'
Requirement needed
By Nailing Inspection
Document needed is
a Surveyor letter giving the Finished Floor Elevation
Document receieved
Yes
Fema map number
12023C0290D
In floodway
N
This is the construction of a
Single Family Dwelling
Setbacks Front
25
Setback Side 1
10
Setback Side 2
10
Setbacks Rear
15
Stories
1
Heated Area (Sqft)
1756
Total Area (Sqft)
2316
Building Height
19
Building Code Construction Type
V
Building Code Element
B
Building Code Occupancy Types
Residential
Occupancy Use Title
single family
Building Code Edition
Florida Building Code 2017 6th Edition & 2014 National Electrical Code
Septic# (00-0000) or (X00-000)
21-0947

Status & Review History

  1. Point Review - Received-Hard Copy Application
  2. Point Review - Reviewed
  3. Zoning Review - Reviewed
  4. Plan Review - Reviewed
  5. Zoning Review - Reviewed
  6. Final Review - Payment Needed
  7. Permit Issued
  8. Final Review - Payment Needed

Contractors

  • Joseph C Peurrung

    Benchmark Builders Llc

    License
    CBC1259347
    Title
    Cert. Building
    Role
    Contractor
  • Marcus Matthews

    Matthews Electric Llc

    License
    EC13005459
    Title
    Electrical Contractor
    Role
    Subcontractor
  • Robert Jarvis

    Jarvis Heat And Air Llc

    License
    CAC1816766
    Title
    Class "b" A/c
    Role
    Subcontractor

    County License & State License Expired.

  • Cody Barrs

    Barrs Plumbing Inc

    License
    CFC1427145
    Title
    Plumbing Contractor
    Role
    Subcontractor
  • Wilmer Marshall

    Marlin Construction Of Indian River County Inc

    License
    CGC022934
    Title
    Cert. General
    Role
    Subcontractor

    County License & State License & Liability Insurance & Workers Comp Expired.

Inspections

  1. Feb 26, 2021

    Passed: Building - Footer

    Put Ground Wire On Footer Steel Prior To Pour

    Inspected by Troy Crews

  2. Feb 26, 2021

    Passed: Engineering - Setbacks

    Inspected by Troy Crews

  3. Mar 30, 2021

    Passed: Electrical - 1st Underground Rough–In

    Inspected by Troy Crews

  4. Mar 30, 2021

    Passed: Plumbing/Gas - 1st Underground Rough–In

    Need Toilet On Site Prior To Any More Inspections

    Inspected by Troy Crews

  5. Apr 21, 2021

    Passed: Building - Slab

    Fibermesh Concrete

    Inspected by Matt Forsyth

  6. Oct 15, 2021

    Passed: Building - Ext Strapping/Wall Sheathing

    Inspected by Matt Forsyth

  7. Oct 15, 2021

    Rescheduled 10/18/2021:Building - Framing

    Inspected by Matt Forsyth

  8. Oct 15, 2021

    Passed: Building - Roof Decking

    Inspected by Matt Forsyth

  9. Oct 18, 2021

    Failed: Building - Framing

    Calling For Lt19 Strapping Bottom Of Kingpost Garage Door Header Two Each Side

    Inspected by Matt Forsyth

  10. Nov 22, 2021

    Passed: Building - Framing

    Inspected by Matt Forsyth

  11. Nov 22, 2021

    Passed: Electrical - 2nd Rough-In

    Inspected by Matt Forsyth

  12. Nov 22, 2021

    Passed: Mechanical - Rough In

    Inspected by Matt Forsyth

  13. Nov 22, 2021

    Passed: Plumbing/Gas - 2nd Rough-In

    Inspected by Matt Forsyth

  14. Mar 1, 2022

    Passed: Building - Lath/Stucco

    Inspected by Troy Crews

  15. Jul 15, 2022

    Passed: Electrical - Permanent Power

    Need Septic And Driveway Release

    Inspected by Matt Forsyth

  16. Jul 25, 2022

    Release to power company

    Inspected by Melissa Garber

  17. Jul 25, 2022

    Septic Release Inspection

    Inspected by Health Dept

  18. Sep 6, 2022

    Rescheduled 9/7/2022:Building - Final

    Inspected by Matt Forsyth

  19. Sep 7, 2022

    Failed: Building - Final

    Fresh Makeup Air Needed For Hvac And Final Termite Treatment

    Inspected by Matt Forsyth

  20. Oct 21, 2022

    Passed: Building - Final

    Make Up Air Confirmed

    Inspected by Matt Forsyth

Documents