Permit Details

Permit Search

Permit

New Residential Construction

7644 NW US HIGHWAY 41
LAKE CITY, FL 32055

Permit #
000041827
Application #
48711
Status Completed
  1. Submitted Apr 13, 2021
  2. Issued Apr 29, 2021
  3. Expires Dec 6, 2022
  4. Completed Jun 9, 2022

Property

Parcel #
01768-092
Owner
Pacheco Hernando
Acres
2.01
Subdivision
Pacheco
Zoning
A-3
Flood zone
X
District
1

Permit

Status
Completed
Septic release
Released
Related permit
—

Job Details

Elevation regulation
Minimum Requirement
Finished floor requirement
One foot above the road
Fema map number
12023C0187D
In floodway
N
This is the construction of a
Single Family Dwelling
Setbacks Front
30'
Setback Side 1
25'
Setback Side 2
25'
Setbacks Rear
25'
Stories
1
Heated Area (Sqft)
1510
Total Area (Sqft)
2134.6
Building Height
18
Building Code Construction Type
V
Building Code Element
B
Building Code Occupancy Types
Residential
Occupancy Use Title
single family dwelling
Building Code Edition
2020 Florida Building Code 7th Edition and 2017 National Electrical Code
Septic# (00-0000) or (X00-000)
21-0326
Sealed roof decking options. (Must select one option per FBC 2023 8th Edition)
two layers of felt underlayment comply ASTM 0226 Type II or ASTM D4869 Type Ill or IV, or two layers of a synthetic underlayment meeting the performance requirements specified, lapped and fastened as specified.

Status & Review History

  1. Application pending.
  2. Point Review - Printed-Online Application
  3. Point Review - Reviewed
  4. Zoning Review - Corrections Needed
  5. Zoning Review - Reviewed
  6. Plan Review - Reviewed
  7. Zoning Review - Reviewed
  8. Final Review - Documents Required
  9. Final Review - Payment Needed
  10. Permit Issued
  11. Final Review - Payment Needed

Contractors

  • Cecilio Garcia

    Kg Construction Llc

    License
    CRC1329233
    Title
    Cert Residential
    Role
    Contractor

    County License & State License & Liability Insurance & Workers Comp Expired.

  • Lee Holloway

    Ldm Construction Co Inc & Peninsular Electric Co

    License
    EC0000668
    Title
    Electrical Contractor
    Role
    Subcontractor

    County License & State License & Workers Comp Expired.

  • Clinton G Wilson

    Wilson Heat & Air Inc

    License
    CAC057886
    Title
    Class B A/c
    Role
    Subcontractor
  • Cody Barrs

    Barrs Plumbing Inc

    License
    CFC1427145
    Title
    Plumbing Contractor
    Role
    Subcontractor

Inspections

  1. May 10, 2021

    Passed: Building - Footer

    Inspected by Troy Crews

  2. May 10, 2021

    Passed: Engineering - Setbacks

    Inspected by Troy Crews

  3. May 10, 2021

    Passed: Electrical - Temporary Service

    Inspected by Troy Crews

  4. May 10, 2021

    Release to power company

    Inspected by Troy Crews

  5. Jun 14, 2021

    Passed: Plumbing/Gas - 1st Underground Rough–In

    Inspected by Troy Crews

  6. Jun 17, 2021

    Passed: Building - Slab

    Inspected by Troy Crews

  7. Sep 7, 2021

    Passed: Building - Roof Decking

    Inspected by Troy Crews

  8. Sep 7, 2021

    Failed: Building - Framing

    Anchor Bolts Missing Check At Green Paint, Also Check 4 Ft. Spacing, Check Truss Bracing And Strapping, Need Heavy Girder Tie Downs Each Side Of Garage Opening, Need To Strap All Headers

    Inspected by Troy Crews

  9. Oct 6, 2021

    Failed: Building - Framing

    A-7 Truss Needs Straps Put Interior Studs Back In

    Inspected by Troy Crews

  10. Oct 6, 2021

    Failed: Electrical - 2nd Rough-In

    Plug For Whirlpool Must Be Installed Prior To Insulation

    Inspected by Troy Crews

  11. Oct 6, 2021

    Passed: Mechanical - Rough In

    Inspected by Troy Crews

  12. Oct 6, 2021

    Passed: Plumbing/Gas - 2nd Rough-In

    Inspected by Troy Crews

  13. Nov 8, 2021

    Passed: Building - Insulation

    Inspected by Troy Crews

  14. Nov 8, 2021

    Passed: Building - Framing

    Items Corrected

    Inspected by Troy Crews

  15. Nov 8, 2021

    Passed: Electrical - 2nd Rough-In

    Plug Installed.

    Inspected by Troy Crews

  16. Feb 18, 2022

    Failed: Electrical - Permanent Power

    Need Final Septic Inspection, Need Garage Door And All Exterior Doors Lockable, Need Ground Rods Connected.

    Inspected by Troy Crews

  17. Mar 21, 2022

    Passed: Electrical - Permanent Power

    Need Final Septic Release

    Inspected by Troy Crews

  18. Apr 13, 2022

    Release to power company

    Inspected by Melissa Garber

  19. Apr 13, 2022

    Septic Release Inspection

    Inspected by Health Dept

  20. May 31, 2022

    Failed: Building - Final

    Need Blower Door Test, Final Termite Treatment, No Gfci Protection In Areas Needed Breakers Appear To Be Only Afci

    Inspected by Troy Crews

  21. Jun 9, 2022

    Passed: Building - Final

    Contractor To Put Gfci On Washer Plug In Garage

    Inspected by Troy Crews

Documents