Permit Details

Permit Search

Permit

New Residential Construction

203 NW MILO TER
LAKE CITY, FL 32055

Permit #
000041459
Application #
48472
Status Completed
  1. Submitted Dec 8, 2021
  2. Issued Mar 4, 2021
  3. Expires Aug 10, 2022
  4. Completed Feb 11, 2022

Property

Parcel #
02032-204
Owner
Sean & Hillary Todd
Acres
5.64
Subdivision
Hills Of Huntsville Phase 2
Zoning
A-3
Flood zone
X
District
3

Permit

Status
Completed
Septic release
Released
Related permit
—

Job Details

Elevation regulation
Subdivision Plat
Finished floor requirement
120'
Requirement needed
By Nailing Inspection
Document needed is
a Surveyor letter giving the Finished Floor Elevation
Document receieved
Yes
Fema map number
12023C0280D
In floodway
N
This is the construction of a
Single Family Dwelling
Setbacks Front
30'
Setback Side 1
25'
Setback Side 2
25'
Setbacks Rear
25'
Stories
1
Heated Area (Sqft)
2310
Total Area (Sqft)
3311
Building Height
24
Building Code Construction Type
V
Building Code Element
B
Building Code Occupancy Types
Residential
Occupancy Use Title
single family dwelling
Building Code Edition
2020 Florida Building Code 7th Edition and 2017 National Electrical Code
Septic# (00-0000) or (X00-000)
25-0542

Status & Review History

  1. Point Review - Status Cleared
  2. Point Review - Received-Hard Copy Application
  3. Zoning Review - Reviewed
  4. Plan Review - Documents Required
  5. Plan Review - Reviewed
  6. Zoning Review - Reviewed
  7. Final Review - Reviewed
  8. Permit Issued
  9. Final Review - Payment Needed
  10. Final Review - Payment Needed
  11. Final Review - Payment Needed

Contractors

  • Patrick Jones

    Chris Mill Homes Of Florida Inc

    License
    CRC1332817
    Title
    Cert. Residential
    Role
    Contractor

    County License & State License Expired.

  • Richard J Turner

    Turner Electrical Services

    License
    ES12000280
    Title
    Specialty Residential Electric
    Role
    Subcontractor

    County License & State License & Liability Insurance & Workers Comp & Employees Workers Comp Expired.

  • Matthew Green

    Greens Sales & Services 2 Inc

    License
    CAC1820394
    Title
    Cert. A/c Class “b”
    Role
    Subcontractor
  • Ronald D Cochran

    Cochran Plumbing Services Llc

    License
    CFC1429154
    Title
    Plumbing Contractor
    Role
    Subcontractor

    County License & State License & Workers Comp Expired.

Inspections

  1. Apr 9, 2021

    Passed: Plumbing/Gas - 1st Underground Rough–In

    Will Need Compaction Test On Soil

    Inspected by Matt Forsyth

  2. Apr 14, 2021

    Passed: Building - Slab

    Fibermesh Concrete

    Inspected by Matt Forsyth

  3. Jun 25, 2021

    Passed: Electrical - Temporary Service

    Inspected by Troy Crews

  4. Jun 25, 2021

    Release to power company

    Inspected by Troy Crews

  5. Jul 12, 2021

    Failed: Building - Roof Decking

    All Nails In Roof Sheating That Missed A Framing Member To Be Removed And Renailed.

    Inspected by Matt Forsyth

  6. Jul 12, 2021

    Failed: Building - Wall Sheathing

    Nails Missing Framing Member In Wall To Be Removed And Renailed. Wall Sheeting On North Wall Bowed Out

    Inspected by Matt Forsyth

  7. Jul 12, 2021

    Passed: Electrical - 2nd Rough-In

    Inspected by Matt Forsyth

  8. Jul 12, 2021

    Passed: Mechanical - Rough In

    Inspected by Matt Forsyth

  9. Jul 12, 2021

    Failed: Plumbing/Gas - 2nd Rough-In

    Water Supply Lines Need Relieving Arch Coming Through Wall.(to Prevent Line From Kinking

    Inspected by Matt Forsyth

  10. Jul 12, 2021

    Failed: Building - Framing

    Plans Call For 2 By 10 Header Framing Members,carpenters Used Box Beam Header Technique. Need Letter From Engineer That This is Acceptable.

    Inspected by Matt Forsyth

  11. Jul 12, 2021

    Passed: Plumbing/Gas - 2nd Rough-In

    Item Addressed With Plumbing Contractor

    Inspected by Matt Forsyth

  12. Jul 16, 2021

    Passed: Building - Roof Decking

    Inspected by Matt Forsyth

  13. Jul 16, 2021

    Passed: Building - Wall Sheathing

    Inspected by Matt Forsyth

  14. Jul 27, 2021

    Passed: Building - Framing

    Box Beams Acceptable

    Inspected by Matt Forsyth

  15. Jul 27, 2021

    Passed: Building - Insulation

    Inspected by Matt Forsyth

  16. Sep 23, 2021

    Septic Release Inspection

    Inspected by Health Dept

  17. Sep 29, 2021

    Failed: Electrical - Permanent Power

    Need Conduit For Service Entrance Run To Meter Can Also Driveway Release

    Inspected by Matt Forsyth

  18. Oct 25, 2021

    Passed: Electrical - Permanent Power

    Need Driveway Released

    Inspected by Matt Forsyth

  19. Dec 8, 2021

    Release to power company

    Inspected by Melissa Garber

  20. Jan 20, 2022

    Failed: Building - Final

    Need Final Termite Treatment, Also Several Recepticals Need To Be Looked That Are Not Reseting Need Labels In Panel Where To Reset Recept.if Not In Panel Box Assessment Fees Need To Be Paid

    Inspected by Matt Forsyth

  21. Jan 28, 2022

    Failed: Building - Final

    Electrical Work Still Needs Attention

    Inspected by Matt Forsyth

  22. Feb 4, 2022

    Failed: Building - Final

    Refrigerator Receptacle Would Not Trip Out

    Inspected by Matt Forsyth

  23. Feb 11, 2022

    Passed: Building - Final

    Inspected by Matt Forsyth

Documents