Permit Details

Permit Search

Permit

Mobile Home

1625 SW OLD SPANISH RD
FORT WHITE, FL 32038

Permit #
000041381
Application #
48289
Status Completed
  1. Submitted Jan 28, 2021
  2. Issued Feb 23, 2021
  3. Expires Sep 26, 2021
  4. Completed Mar 30, 2021

Property

Parcel #
00502-058
Owner
Paul & Mary Pestrichello
Acres
15.90
Subdivision
Ichetucknee Forest Tract "a" Phase 1 Replat
Zoning
ESA-2
Flood zone
X
District
2

Permit

Status
Completed
Septic release
Released
Related permit
—

Job Details

Elevation regulation
Minimum Requirement
Finished floor requirement
One foot above the road
Fema map number
12023C0460C
In floodway
N
Mobile Home is a:
Single Wide
Year Built
2016
Width (Ft.In)
16
Length (Ft.In)
80
Driveway access to home:
Existing Drive
Installation Decal #
76070
Septic #
21-0093
Setbacks Front
30'
Setback Side 1
25'
Setbacks Rear
25'
Dev Permit #
F023-
Setback Side 2
25'
Are you applying for a 5 year temporary permit?
No
Serial #
LOHGA21530574
Wind Zone?
2
Residential or Commercial Use?
Residential

Status & Review History

  1. Application pending.
  2. Point Review - Printed-Online Application
  3. Zoning Review - Reviewed
  4. Plan Review - Reviewed
  5. Final Review - Documents Required
  6. Permit Issued

Contractors

  • Dale Houston

    Dale Houstons Mobile Home Set Up And Service

    License
    IH1025142
    Title
    Mh Installer (ih)
    Role
    Contractor
  • James D Williams

    Affordable Electrical Services Inc

    License
    EC13007092
    Title
    Electrical Contractor
    Role
    Subcontractor

    County License & State License Expired.

  • Steven M Mollman

    Mollman Air Conditioning And Refrigeration Llc

    License
    CAC1819696
    Title
    Cert. A/c Class “b”
    Role
    Subcontractor

Inspections

  1. Feb 22, 2021

    Passed: Mobile Home - In County Pre-Mobile Home before set-up

    Inspected by Matt Forsyth

  2. Feb 23, 2021

    Septic Release Inspection

    Inspected by Health Dept

  3. Mar 11, 2021

    Failed: Mobile Home - Mobile Home Set-Up Final

    Need Landing And Steps Need Proof Of Heat In Home

    Inspected by Matt Forsyth

  4. Mar 11, 2021

    Passed: Engineering - Setbacks

    Inspected by Matt Forsyth

  5. Mar 24, 2021

    Failed: Mobile Home - Mobile Home Set-Up Final

    No Heat In Mobile Home

    Inspected by Matt Forsyth

  6. Mar 24, 2021

    Passed: Engineering - Setbacks

    Inspected by Matt Forsyth

  7. Mar 30, 2021

    Passed: Mobile Home - Mobile Home Set-Up Final

    Inspected by Matt Forsyth

  8. Mar 30, 2021

    Release to power company

    Inspected by Matt Forsyth

  9. Mar 30, 2021

    Passed: Engineering - Setbacks

    Inspected by Matt Forsyth