Permit Details

Permit Search

Permit

New Residential Construction

292 SW BRADSHAW GLN
LAKE CITY, FL 32024

Permit #
000041066
Application #
47546
Status Completed
  1. Submitted Oct 16, 2020
  2. Issued Dec 23, 2020
  3. Expires May 22, 2022
  4. Completed Nov 23, 2021

Property

Parcel #
03397-021
Owner
Handy Brent
Acres
4.69
Subdivision
—
Zoning
A-3
Flood zone
X
District
5

Permit

Status
Completed
Septic release
Released
Related permit
—

Job Details

Elevation regulation
Minimum Requirement
Finished floor requirement
One foot above the road
Fema map number
12023C0383D
In floodway
N
This is the construction of a
Single Family Dwelling
Setbacks Front
30'
Setback Side 1
25'
Setback Side 2
25'
Setbacks Rear
25'
Stories
2
Heated Area (Sqft)
2709
Total Area (Sqft)
3073
Building Height
27
Building Code Construction Type
V
Building Code Element
B
Building Code Occupancy Types
Residential
Occupancy Use Title
single family
Building Code Edition
Florida Building Code 2017 6th Edition & 2014 National Electrical Code
Septic# (00-0000) or (X00-000)
20-0988

Status & Review History

  1. Application pending.
  2. Point Review - Printed-Online Application
  3. Zoning Review - Corrections Needed
  4. Zoning Review - Reviewed
  5. Plan Review - Documents Required
  6. Plan Review - Documents Required
  7. Plan Review - Reviewed
  8. Final Review - Documents Required
  9. Final Review - Payment Needed
  10. Permit Issued
  11. Final Review - Payment Needed

Contractors

  • Isaiah Cully

    Ic Construction Llc

    License
    CBC1259655
    Title
    Building Contractor
    Role
    Contractor
  • Everton D Ruddock

    D&s Lighting Inc

    License
    EC13003800
    Title
    Electrical Contractor
    Role
    Subcontractor
  • Clinton G Wilson

    Wilson Heat & Air Inc

    License
    CAC057886
    Title
    Class B A/c
    Role
    Subcontractor
  • Cody Barrs

    Barrs Plumbing Inc

    License
    CFC1427145
    Title
    Plumbing Contractor
    Role
    Subcontractor
  • Tyler M Turner

    Tmt Roofing Llc

    License
    CCC1330410
    Title
    Cert Roofing
    Role
    Subcontractor

Inspections

  1. Jan 11, 2021

    Passed: Plumbing/Gas - 1st Underground Rough–In

    Inspected by Matt Forsyth

  2. Jan 14, 2021

    Passed: Building - Slab

    Inspected by Matt Forsyth

  3. Feb 25, 2021

    Passed: Building - Ext Strapping/Wall Sheathing

    Still Need Inspection On North End Bonus Room Wall For Nailing

    Inspected by Matt Forsyth

  4. Mar 4, 2021

    Failed: Building - Ext Strapping/Wall Sheathing

    Need Strapping Lst30 Tieing Wall And Gable

    Inspected by Matt Forsyth

  5. Mar 10, 2021

    Passed: Building - Ext Strapping/Wall Sheathing

    Strapping Completed

    Inspected by Matt Forsyth

  6. Apr 23, 2021

    Passed: Building - Framing

    Inspected by Matt Forsyth

  7. Apr 23, 2021

    Passed: Electrical - 2nd Rough-In

    Nail Plate Needed Bedrm4

    Inspected by Matt Forsyth

  8. Apr 23, 2021

    Failed: Mechanical - Rough In

    Need Exaustfan Duct In Toilet Room. Condensate Line Needs Nail Plate Laundry Rm

    Inspected by Matt Forsyth

  9. Apr 23, 2021

    Failed: Plumbing/Gas - 2nd Rough-In

    Pex Piping In Top Of Wall On The Exterior Needs Pipe Insulation

    Inspected by Matt Forsyth

  10. May 7, 2021

    Passed: Mechanical - Rough In

    Inspected by Matt Forsyth

  11. May 7, 2021

    Failed: Plumbing/Gas - 2nd Rough-In

    Item Was Not Taken Care Of On The Last Inspection Protection Of Water Pipe On Exterior Wall Top Plate

    Inspected by Matt Forsyth

  12. May 7, 2021

    Passed: Plumbing/Gas - 2nd Rough-In

    Foam Insulation Will Be Used For Protection

    Inspected by Matt Forsyth

  13. May 21, 2021

    Failed: Building - Insulation

    Installation Was Started But Not Finished

    Inspected by Matt Forsyth

  14. May 25, 2021

    Passed: Building - Insulation

    Inspected by Matt Forsyth

  15. Aug 3, 2021

    Septic Release Inspection

    Inspected by Health Dept

  16. Sep 8, 2021

    Passed: Electrical - Permanent Power

    Inspected by Troy Crews

  17. Sep 8, 2021

    Release to power company

    Inspected by Troy Crews

  18. Nov 23, 2021

    Passed: Building - Final

    Inspected by Matt Forsyth

Documents