Permit Information

New Residential Construction Permit

Address 233 SW SCRUBTOWN RD
FORT WHITE, FL 32038
Parcel #: 09898-007
Acres:1.10
Owner:Ryan & Fairen Frisinger
Subdivision:
Zoning:A-3
Flood Zone:X
District:4
Application #:47814
Permit #: 000041058
Related Permit: Culvert Waiver: 000041059
Submitted:Tuesday, November 24, 2020
Issued:Monday, August 3, 2026
Expires:Tuesday, August 3, 2027
Completed:
Status: Permit Renewed
Septic Release? No

Notes

PER PRIOR PERMITS ISSUED FOR ADJACENT LOTS, THE SUBJECT PROPERTY WAS PART OF AN OLD FAMILY LOT DIVISION. RENEWED PERMIT 3/30/2022-- SEE DOCUMENTS

Job Details

Elevation regulation Minimum Requirement
Finished floor requirement One foot above the road
Fema map number 12023C0495C
In floodway N
This is the construction of a Single Family Dwelling
Setbacks Front 30
Setback Side 1 25
Setback Side 2 25
Setbacks Rear 25
Stories 1
Heated Area (Sqft) 1204
Total Area (Sqft) 1204
Building Height 9
Building Code Construction Type V
Building Code Element B
Building Code Occupancy Types Residential
Occupancy Use Title single family
Building Code Edition Florida Building Code 2017 6th Edition & 2014 National Electrical Code
Septic# (00-0000) or (X00-000) 20-1000

Review Notes

11/19/2020 Application pending.
11/25/2020 Point Review - Printed-Online Application
11/30/2020 Zoning Review - Reviewed
12/7/2020 Plan Review - Reviewed
12/7/2020 Zoning Review - Reviewed
12/7/2020 Final Review - Documents Required
12/22/2020 Permit Issued
3/29/2022 Zoning Review - Reviewed
3/30/2022 Final Review - Payment Needed
3/30/2022 Permit Renewed
8/3/2026 Permit Renewed

Contractors

Name / Business License Title Role

Inspections

Inspection Notes Performed By Date
Passed: Electrical - Temporary Service Anthony Aslan 12/23/2020
Release to power company Anthony Aslan 12/23/2020
Failed: Plumbing/Gas - 1st Underground Rough–In Not Ready No Plumbing Installed Anthony Aslan 7/7/2022
Cancelled: Plumbing/Gas - 1st Underground Rough–In Anthony Aslan 7/18/2022
Passed: Engineering - Spot Check Talked With Home Owners About Plumbing Anthony Aslan 7/18/2022
Passed: Plumbing/Gas - 1st Underground Rough–In Anthony Aslan 10/12/2022
Passed: Engineering - Setbacks Anthony Aslan 10/20/2022
Passed: Building - Monolithic Slab Need Termite Letter From Owner, Compaction Test Anthony Aslan 10/20/2022
Failed: Building - Framing Call Back When Sheathing Is Installed Anthony Aslan 12/30/2022
Cancelled: Building - Ext Strapping/Wall Sheathing Anthony Aslan 1/3/2023
Passed: Building - Ext Strapping/Wall Sheathing Anthony Aslan 2/17/2023
Passed: Building - Framing Need Anchors At Splices Bottom Plate Anthony Aslan 2/17/2023
Passed: Building - Roof Decking Anthony Aslan 2/17/2023
Passed: Plumbing/Gas - 2nd Rough-In Owner To Pressure Test Water Piping Prior To Sheetrock Troy Crews 9/14/2026
Passed: Electrical - 2nd Rough-In Troy Crews 9/14/2026

Documents

File Name Date File Size

Contact Us

Building Department

Office Hours

Monday-Friday
8:00 A.M. - 4:30 P.M.

Contact Information

Phone: 386-758-1008
Fax: 386-758-2160

Email: bldginfo@columbiacountyfla.com

Location

135 NE Hernando Ave.
Lake City, FL 32055 (opens in new window)

Mailing Address

P.O. Box 1529
Lake City, FL 32056-1529

Public Records

Public records policy and fees

Board of County Commissioners
Tel. (386) 758-1326
Fax: (386) 758-2182
Email: publicrecords@columbiacountyfla.com

Mailing Address:
P.O. Box 1529
Lake City, FL 32056-1529

Citizen Feedback

Let us know how we're doing

ADA Accessibility

Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the Columbia County ADA Coordinator at (386) 758-3344. You may also email that office at hr@columbiacountyfla.com and provide a brief description of the inaccessible feature.

Columbia County strives to provide reasonable accommodations to help people with disabilities have an equal opportunity to participate in our public meetings. Please notify our ADA Coordinator at least 48 hours prior to the public meeting by calling (386) 758-3344.