Storage Building
Permit
| Application #: | 47741 |
| Permit #: |
000041053 |
| Related Permit: |
|
| Submitted: | Tuesday, November 10, 2020 |
| Issued: | Tuesday, December 22, 2020 |
| Expires: | Monday, September 20, 2021 |
| Completed: | Monday, September 20, 2021 |
| Status: |
Completed |
| Septic Release? |
No |
Job Details
| Elevation regulation |
Accessory Use |
| Finished floor requirement |
Non-Habitable Structure |
| Fema map number |
12023C0395C |
| In floodway |
N |
| Type of Structure |
Other |
| Commercial or Residential? |
Residential |
| Total Area (Sqft) |
576 |
| Setbacks Front |
30 |
| Setback Side 1 |
25 |
| Setback Side 2 |
25 |
| Setback Rear |
25 |
| Building Code Construction Type |
V |
| Building Code Element |
B |
| Building Code Occupancy Types |
Residential |
| Occupancy Use Title |
single family |
| Dev Permit # |
F023- |
| Building Code Edition |
Florida Building Code 2017 6th Edition & 2014 National Electrical Code |
| Building Height |
16 |
| Building Length |
24 |
| Building Width |
24 |
Review Notes
| 11/10/2020 |
Application pending. |
| 11/10/2020 |
Point Review - Printed-Online Application |
| 11/19/2020 |
Plan Review - Documents Required |
| 11/19/2020 |
Zoning Review - Reviewed |
| 11/24/2020 |
Plan Review - Documents Required |
| 12/8/2020 |
Plan Review - Reviewed |
| 12/11/2020 |
Zoning Review - Reviewed |
| 12/11/2020 |
Final Review - Payment Needed |
| 12/22/2020 |
Permit Issued |
Contractors
| Name / Business |
License |
Title |
Role |
Bryan Zecher Bryan Zecher Construction Inc
|
CBC054575 |
Cert.building Contractor |
Contractor |
Marcus Matthews Matthews Electric Llc
|
EC13005459 |
Electrical Contractor |
Subcontractor |
Anthony R Franks Franks & Lane Heating And Air Llc
|
CAC1818631 |
Cert. A/c Class “b” |
Subcontractor |
Cody Barrs Barrs Plumbing Inc
|
CFC1427145 |
Plumbing Contractor |
Subcontractor |
Robert Ogles Ii Ogles Roofing & Construction Llc
|
CCC1328699 |
Cert Roofing |
Subcontractor |
Inspections
| Inspection |
Notes |
Performed By |
Date |
| Cancelled: Building - Footer |
|
Troy Crews |
1/5/2021 |
| Cancelled: Engineering - Setbacks |
|
Troy Crews |
1/5/2021 |
| Passed: Plumbing/Gas - 1st Underground Rough–In |
|
Troy Crews |
2/8/2021 |
| Passed: Building - Roof Decking |
|
Anthony Aslan |
4/13/2021 |
| Cancelled: Building - Ext Strapping/Wall Sheathing |
|
Anthony Aslan |
4/13/2021 |
| Cancelled: Building - Wall Sheathing |
|
Anthony Aslan |
4/13/2021 |
| Passed: Building - Monolithic Slab |
Slab Under Pavillion With Fireplace Footer |
Troy Crews |
4/20/2021 |
| Passed: Engineering - Setbacks |
|
Troy Crews |
4/20/2021 |
| Passed: Building - Framing |
|
Troy Crews |
4/20/2021 |
| Passed: Building - Masonry Wall Reinforcing |
|
Troy Crews |
5/5/2021 |
| Passed: Building - Ext Strapping/Wall Sheathing |
|
Troy Crews |
5/5/2021 |
| Passed: Electrical - Permanent Power |
Need Septic Release |
Troy Crews |
7/14/2021 |
| Passed: Building - Final |
|
Troy Crews |
9/20/2021 |