CHECK SETBACKS FROM DRAINAGE EASEMENT

Job Details

Elevation regulation Minimum Requirement
Finished floor requirement One foot above the road
Fema map number 12023C0290D
In floodway N
This is the construction of a Single Family Dwelling
Setbacks Front 25
Setback Side 1 10
Setback Side 2 10
Setbacks Rear 15
Stories 1
Heated Area (Sqft) 3465
Total Area (Sqft) 4655
Building Height 22
Building Code Construction Type V
Building Code Element B
Building Code Occupancy Types Residential
Occupancy Use Title single family
Building Code Edition Florida Building Code 2017 6th Edition & 2014 National Electrical Code
Septic# (00-0000) or (X00-000) 20-0917

Review Notes

11/3/2020 Application pending.
11/3/2020 Point Review - Printed-Online Application
11/16/2020 Plan Review - Reviewed
11/17/2020 Zoning Review - Reviewed
11/17/2020 Final Review - Documents Required
12/2/2020 Final Review - Payment Needed
12/3/2020 Permit Issued
8/10/2021 Final Review - Payment Needed

Contractors

Name / Business License Title Role
Kevin L Bedenbaugh Jr
Plumb Level Construction Co Llc
CGC1516042 General Contractor Contractor
Mark A Ganskop
Express Plumbing Inc
CFC1428040 Plumbing Contractor Subcontractor
Ryan Felknor
Felknor Electric, Inc.
EC13003153 Electrical Contractor Subcontractor
Timothy D Shatto
Shatto Heating & Air, Inc.
CAC057875 A/c Class B Subcontractor
Kevin L Bedenbaugh Jr
Plumb Level Construction Co Llc
CCC1329482 Roofing Contractor Subcontractor

Inspections

Inspection Notes Performed By Date
Passed: Building - Footer Matt Forsyth 12/14/2020
Passed: Engineering - Setbacks Matt Forsyth 12/14/2020
Failed: Plumbing/Gas - 1st Underground Rough–In Test Stack Needs To Be On High End Of System Matt Forsyth 1/11/2021
Passed: Plumbing/Gas - 1st Underground Rough–In Matt Forsyth 1/11/2021
Failed: Building - Slab Missing #5 Bar In Garage Footing Matt Forsyth 1/13/2021
Passed: Building - Slab #5 Bar In Continuous Footing For Garage Matt Forsyth 1/13/2021
Passed: Building - Roof Decking Matt Forsyth 2/9/2021
Passed: Building - Wall Sheathing Matt Forsyth 2/9/2021
Failed: Building - Framing 2 Windows Upstairs Need To Be Tempered Glass Matt Forsyth 3/24/2021
Failed: Building - Strapping Strapping Was Covered Up With Finished Hardie Board Matt Forsyth 3/24/2021
Passed: Electrical - 2nd Rough-In Matt Forsyth 3/24/2021
Failed: Mechanical - Rough In Exhaust Fans In Bathrooms Were Not Installed Matt Forsyth 3/24/2021
Failed: Plumbing/Gas - 2nd Rough-In Need Nail Plate For Top Of Wall For Gas Line On Exterior Wall Matt Forsyth 3/24/2021
Passed: Electrical - Temporary Service Matt Forsyth 4/9/2021
Release to power company Matt Forsyth 4/9/2021
Passed: Building - Insulation Matt Forsyth 4/15/2021
Passed: Building - Framing Matt Forsyth 4/15/2021
Passed: Building - Strapping Matt Forsyth 4/15/2021
Passed: Mechanical - Rough In Matt Forsyth 4/15/2021
Passed: Plumbing/Gas - 2nd Rough-In Matt Forsyth 4/15/2021
Septic Release Inspection Health Dept 8/4/2021
Passed: Electrical - Permanent Power Matt Forsyth 8/11/2021
Release to power company Matt Forsyth 8/11/2021
Failed: Building - Final House Needs To Be Finished,blower Door Test Matt Forsyth 10/25/2021
Passed: Building - Final Check Front And Back Porch Plugs Make Sure Gfci Protected Troy Crews 11/9/2021

Documents

File Name Date File Size
34w2or3s.yxq.pdf 2025.07.14 904.76kB
2xb54ony.sov.pdf 2025.07.14 1.00MB
Power Release-release To Power Company 20220503.pdf 2025.07.05 11.41kB
Surveyor Letter Giving The Finished Floor Elevation 20211229 153637.pdf 2025.07.05 28.22kB
Site Plan 20210628 093254.pdf 2025.07.05 66.27kB
Lidar 49724 2021-07-12 15.37.48.397.pdf 2025.07.05 144.80kB
602 Sw Mandiba Termite Final 2022-05-11 14.06.12.228.pdf 2025.07.05 119.01kB
Manual J Forms 20210708 123311.pdf 2025.07.05 114.27kB
Gomez Eh 2022-05-03 08.24.51.993.pdf 2025.07.05 529.07kB
42486 Blower Door 2022-05-11 14.07.52.341.pdf 2025.07.05 305.29kB
Subcontractor Form 20210623 130014.pdf 2025.07.05 445.41kB
Property Appraiser Parcel Details Printed Page 20210623 130013.pdf 2025.07.05 666.09kB
Residential Or Commercial Checklist 20210623 130013.pdf 2025.07.05 520.02kB
Subdivision Plat 2021-06-29 14.58.05.924.pdf 2025.07.04 1.03MB
Owner And Contractor Signature Page 20210623 111023.pdf 2025.07.04 368.66kB
911 Address 2021-06-29 14.04.22.871.pdf 2025.07.04 1.36MB
Architectural Plans 20210623 130012.pdf 2025.07.04 1.36MB
Certificate Of Occupancy 20220511.pdf 2025.06.23 62.17kB
Sealed S2.pdf 2025.06.22 569.22kB
Sealed S1.pdf 2025.06.22 785.11kB
Sealed S4.pdf 2025.06.21 1.10MB
Sealed S3.pdf 2025.06.21 1.41MB
Win_20210923_16_11_01_pro 2021-09-23 16.14.42.311.jpg 2025.06.20 229.27kB
Recorded Noc 2021-08-24 16.07.46.83.pdf 2023.12.23 68.70kB
Product Approval Code Specifications Form 20210623 130012.pdf 2023.12.23 748.01kB
Power Release-electrical-temporary Service 20210914.pdf 2021.09.14 38.80kB
Original Permit 20210804.pdf 2021.08.04 43.17kB
Energy Code Forms.pdf 2021.07.27 63.22kB

Contact Us

Building Department

Office Hours

Monday-Friday
8:00 A.M. - 4:30 P.M.

Contact Information

Phone: 386-758-1008
Fax: 386-758-2160

Email: bldginfo@columbiacountyfla.com

Location

135 NE Hernando Ave.
Lake City, FL 32055 (opens in new window)

Mailing Address

P.O. Box 1529
Lake City, FL 32056-1529

Public Records

Public records policy and fees

Board of County Commissioners
Tel. (386) 758-1326
Fax: (386) 758-2182
Email: publicrecords@columbiacountyfla.com

Mailing Address:
P.O. Box 1529
Lake City, FL 32056-1529

Citizen Feedback

Let us know how we're doing

ADA Accessibility

Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the Columbia County ADA Coordinator at (386) 758-3344. You may also email that office at hr@columbiacountyfla.com and provide a brief description of the inaccessible feature.

Columbia County strives to provide reasonable accommodations to help people with disabilities have an equal opportunity to participate in our public meetings. Please notify our ADA Coordinator at least 48 hours prior to the public meeting by calling (386) 758-3344.