Permit Details

Permit Search

Permit

New Residential Construction

451 NW COUNTRY LAKE DR
LAKE CITY, FL 32055

Permit #
000040759
Application #
47419
Status Completed
  1. Submitted Oct 8, 2020
  2. Issued Dec 16, 2020
  3. Expires Jan 23, 2022
  4. Completed Jul 27, 2021

Property

Parcel #
02267-432
Owner
Margaret Mckenzie
Acres
0.93
Subdivision
Country Lake In Woodborough Phase 4
Zoning
RSF-2
Flood zone
X
District
3

Permit

Status
Completed
Septic release
Released
Related permit
—

Job Details

Elevation regulation
Engineers Elevation Letter
Finished floor requirement
135.16'
Requirement needed
By Nailing Inspection
Document needed is
a Surveyor letter giving the Finished Floor Elevation
Document receieved
Yes
Fema map number
12023C0280D
In floodway
N
This is the construction of a
Single Family Dwelling
Setbacks Front
25'
Setback Side 1
10'
Setback Side 2
10'
Setbacks Rear
15'
Stories
1
Heated Area (Sqft)
2025
Total Area (Sqft)
3124
Building Height
19
Building Code Construction Type
V
Building Code Element
B
Building Code Occupancy Types
Residential
Occupancy Use Title
single family
Building Code Edition
Florida Building Code 2017 6th Edition & 2014 National Electrical Code
Septic# (00-0000) or (X00-000)
20-0812

Status & Review History

  1. Application pending.
  2. Point Review - On Hold-Incomplete
  3. Point Review - Printed-Online Application
  4. Zoning Review - Reviewed
  5. Zoning Review - Reviewed
  6. Plan Review - Reviewed
  7. Final Review - Payment Needed
  8. Permit Issued
  9. Permit reissued to reflect updated information.
  10. Final Review - Payment Needed

Contractors

  • Isaiah Cully

    Ic Construction Llc

    License
    CBC1259655
    Title
    Building Contractor
    Role
    Contractor
  • Clinton G Wilson

    Wilson Heat & Air Inc

    License
    CAC057886
    Title
    Class B A/c
    Role
    Subcontractor
  • Everton D Ruddock

    D&s Lighting Inc

    License
    EC13003800
    Title
    Electrical Contractor
    Role
    Subcontractor
  • Cody Barrs

    Barrs Plumbing Inc

    License
    CFC1427145
    Title
    Plumbing Contractor
    Role
    Subcontractor
  • Tyler M Turner

    Tmt Roofing Llc

    License
    CCC1330410
    Title
    Cert Roofing
    Role
    Subcontractor

Inspections

  1. Nov 12, 2020

    Passed: Building - Footer

    Need To Make Sure Lot Does Not Have Set Floor Elevation

    Inspected by Troy Crews

  2. Nov 12, 2020

    Passed: Engineering - Setbacks

    Inspected by Troy Crews

  3. Dec 3, 2020

    Rescheduled 12/4/2020:Plumbing/Gas - 1st Underground Rough–In

    Inspected by Troy Crews

  4. Dec 4, 2020

    Passed: Plumbing/Gas - 1st Underground Rough–In

    Ac Chase Line Over 50 Feet Suction Line Will Need To Be Upsized, Also Put Fall On Dryer Line To Outside

    Inspected by Troy Crews

  5. Dec 9, 2020

    Passed: Building - Slab

    Confirm 12 Inch Above Rd.

    Inspected by Troy Crews

  6. Dec 29, 2020

    Passed: Electrical - Temporary Service

    Inspected by Troy Crews

  7. Dec 29, 2020

    Release to power company

    Inspected by Troy Crews

  8. Feb 3, 2021

    Passed: Building - Roof Decking

    Inspected by Troy Crews

  9. Feb 3, 2021

    Passed: Building - Wall Sheathing

    Inspected by Troy Crews

  10. Feb 5, 2021

    Failed: Building - Framing

    Need Two King Studs All Openings Over 6ft., Missing Heavy Tie Downs At Garage Opening, Also Need Elevation/engineer Letter

    Inspected by Troy Crews

  11. Apr 8, 2021

    Failed: Building - Insulation

    Requested By Builder, Need Framing Inspection Done That Failed, Also Need Electric, Plumbing, And H.v.a.c. Inspections Passed Prior To Insulation May Have To Be Pulled Out In Areas.

    Inspected by Troy Crews

  12. Apr 9, 2021

    Passed: Electrical - 2nd Rough-In

    Inspected by Anthony Aslan

  13. Apr 9, 2021

    Passed: Plumbing/Gas - 2nd Rough-In

    Inspected by Anthony Aslan

  14. Apr 9, 2021

    Failed: Building - Framing

    Insulation Covering Anchors Could Not Verify. Truss T11g Could Not Verify Engineering, Spray Foam Insulation Encapsulated. Truss T12 Has Inadequate Strapping For Uplift, Also Could Not Verify Truss Strapping On Porches. Could Not Verify Outlooker Strapping Encapsulated In Spray Foam Insulation

    Inspected by Anthony Aslan

  15. Apr 9, 2021

    Failed: Mechanical - Rough In

    Could Not Verify Kitchen Exhaust Exiting Termination, Kitchen Hood Vent Needs 3 Screws At Joints Of Pipe. Need To Add Straps To Duct Flex. Return Mixing Box Knocked Off Support.

    Inspected by Anthony Aslan

  16. Apr 15, 2021

    Passed: Mechanical - Rough In

    Made Corrections

    Inspected by Anthony Aslan

  17. Apr 15, 2021

    Failed: Building - Framing

    Truss No Strapped. See Notes On Previous Inspection.

    Inspected by Anthony Aslan

  18. Apr 15, 2021

    Passed: Building - Insulation

    Inspected by Anthony Aslan

  19. Jun 2, 2021

    Septic Release Inspection

    Inspected by Health Dept

  20. Jun 23, 2021

    Failed: Electrical - Permanent Power

    No Front Door

    Inspected by Anthony Aslan

  21. Jun 25, 2021

    Passed: Electrical - Permanent Power

    Rec'd Pictures

    Inspected by Anthony Aslan

  22. Jul 9, 2021

    Release to power company

    Culvert Has Been Finaled 7.12.21 By D.mccormick

    Inspected by Laurie Hodson

  23. Jul 12, 2021

    Passed: Electrical - Permanent Power

    Changed Out To Fpl Approved Can

    Inspected by Troy Crews

  24. Jul 12, 2021

    Release to power company

    Inspected by Troy Crews

  25. Jul 20, 2021

    Cancelled: Building - Final

    Inspected by Anthony Aslan

  26. Jul 22, 2021

    Failed: Building - Final

    1) A/c Condenser Pad Covered By Mulch 2) Back Porch Outlet Has Open Ground Not Tripping Gfci 3) Bath By Garage Door Gfci Reversed Hot & Neutral 4) Disposal Under Kitchen Sink Gfci Open Ground 5) Kitchen Exhaust No Discharge Grill

    Inspected by Anthony Aslan

  27. Jul 22, 2021

    Passed: Building - Framing

    Items Corrected Per Builder

    Inspected by Troy Crews

  28. Jul 23, 2021

    Failed: Building - Final

    M1503.1general. range Hoods Shall Discharge To The Outdoors Through A Duct. The Duct Serving The Hood Shall Have A Smooth Interior Surface, Shall Be Air Tight, Shall Be Equipped With A Back-draft Damper And Shall Be Independent Of All Other Exhaust Systems. Ducts Serving Range Hoods Shall Not Terminate In An Attic Or Crawl Space Or Areas Inside The Building. exception: Where Installed In Accordance With The Manufacturer’s Instructions, And Where Mechanical Or Natural Ventilation Is Otherwise Provided, Listed And Labeled Ductless Range Hoods Shall Not Be Required To Discharge To The Outdoors. m1305.1.4.1ground Clearance. equipment And Appliances Supported From The Ground Shall Be Level And Firmly Supported On A Concrete Slab Or Other Approved Material Extending Not Less Than 3 Inches (76 Mm) Above The Adjoining Ground. Such Support Shall Be In Accordance With The Manufacturer’s Installation Instructions. Appliances Suspended From The Floor Shall Have A Clearance Of Not Less Than 6 Inches (152 Mm) From The Ground. r318.5protection Against Decay And Termites. condensate Lines, Irrigation/sprinkler System Risers For Spray Heads, And Roof Downspouts Shall Discharge At Least 1 Foot (305 Mm) Away From The Structure Sidewall, Whether By Underground Piping, Tail Extensions Or Splash Blocks. Gutters With Downspouts Are Required On All Buildings With Eaves Of Less Than 6 Inches (152 Mm) Horizontal Projection Except For Gable End Rakes Or On A Roof Above Another Roof.

    Inspected by Anthony Aslan

  29. Jul 27, 2021

    Passed: Building - Final

    Corrections Made

    Inspected by Anthony Aslan

Documents