Permit Details

Permit Search

Permit

New Residential Construction

300 NW EMPORIA GLN
LAKE CITY, FL 32055

Permit #
000040718
Application #
47278
Status Completed
  1. Submitted Sep 15, 2020
  2. Issued Oct 15, 2020
  3. Expires Oct 12, 2021
  4. Completed Apr 15, 2021

Property

Parcel #
02272-103
Owner
Womble, William B & Brandalyn M
Acres
5.42
Subdivision
Lakewood Estates
Zoning
RSF-2
Flood zone
X
District
3

Permit

Status
Completed
Septic release
Released
Related permit
—

Job Details

Elevation regulation
Engineers Elevation Letter
Finished floor requirement
141.67'
Requirement needed
By Nailing Inspection
Document needed is
a Surveyor letter giving the Finished Floor Elevation
Document receieved
Yes
Fema map number
12023C0283D
In floodway
N
This is the construction of a
Single Family Dwelling
Setbacks Front
25'
Setback Side 1
10'
Setback Side 2
10'
Setbacks Rear
15'
Stories
1
Heated Area (Sqft)
3363
Total Area (Sqft)
5548
Building Height
27
Building Code Construction Type
V
Building Code Element
B
Building Code Occupancy Types
Residential
Occupancy Use Title
single family
Building Code Edition
Florida Building Code 2017 6th Edition & 2014 National Electrical Code
Septic# (00-0000) or (X00-000)
20-0734

Status & Review History

  1. Application pending.
  2. Point Review - Printed-Online Application
  3. Point Review - Reviewed
  4. Zoning Review - Corrections Needed
  5. Zoning Review - Reviewed
  6. Plan Review - Reviewed
  7. Zoning Review - Reviewed
  8. Final Review - Payment Needed
  9. Final Review - Payment Needed
  10. Final Review - Payment Needed
  11. Permit Issued
  12. Final Review - Payment Needed

Contractors

  • Kevin L Bedenbaugh Jr

    Plumb Level Construction Co Llc

    License
    CGC1516042
    Title
    General Contractor
    Role
    Contractor
  • Mark A Ganskop

    Express Plumbing Inc

    License
    CFC1428040
    Title
    Plumbing Contractor
    Role
    Subcontractor
  • Ryan Felknor

    Felknor Electric, Inc.

    License
    EC13003153
    Title
    Electrical Contractor
    Role
    Subcontractor
  • Timothy D Shatto

    Shatto Heating & Air, Inc.

    License
    CAC057875
    Title
    A/c Class B
    Role
    Subcontractor
  • Kevin L Bedenbaugh Jr

    Plumb Level Construction Co Llc

    License
    CCC1329482
    Title
    Roofing Contractor
    Role
    Subcontractor

Inspections

  1. Oct 28, 2020

    Passed: Electrical - Temporary Service

    Inspected by Troy Crews

  2. Oct 28, 2020

    Release to power company

    Inspected by Troy Crews

  3. Nov 20, 2020

    Passed: Building - Footer

    Inspected by Troy Crews

  4. Nov 20, 2020

    Passed: Engineering - Setbacks

    Inspected by Troy Crews

  5. Dec 7, 2020

    Failed: Plumbing/Gas - 1st Underground Rough–In

    Not Complete

    Inspected by Troy Crews

  6. Dec 8, 2020

    Passed: Plumbing/Gas - 1st Underground Rough–In

    Inspected by Matt Forsyth

  7. Dec 9, 2020

    Passed: Building - Slab

    Inspected by Troy Crews

  8. Dec 23, 2020

    Passed: Building - Wall Sheathing

    Inspected by Matt Forsyth

  9. Jan 11, 2021

    Passed: Building - Framing

    Inspected by Troy Crews

  10. Jan 11, 2021

    Passed: Building - Roof Decking

    Inspected by Troy Crews

  11. Jan 22, 2021

    Passed: Electrical - 2nd Rough-In

    Inspected by Troy Crews

  12. Jan 22, 2021

    Failed: Mechanical - Rough In

    Not Complete

    Inspected by Troy Crews

  13. Jan 22, 2021

    Failed: Plumbing/Gas - 2nd Rough-In

    Check For Nail Plates

    Inspected by Troy Crews

  14. Jan 25, 2021

    Passed: Mechanical - Rough In

    Inspected by Troy Crews

  15. Jan 25, 2021

    Passed: Plumbing/Gas - 2nd Rough-In

    Inspected by Troy Crews

  16. Feb 2, 2021

    Passed: Building - Insulation

    Inspected by Troy Crews

  17. Apr 5, 2021

    Release to power company

    Inspected by Laurie Hodson

  18. Apr 5, 2021

    Passed: Electrical - Permanent Power

    Need Driveway Release, Need Septic Release

    Inspected by Anthony Aslan

  19. Apr 5, 2021

    Septic Release Inspection

    Inspected by Health Dept

  20. Apr 12, 2021

    Cancelled: Building - Final

    Inspected by Melissa Garber

  21. Apr 14, 2021

    Rescheduled 4/15/2021:Building - Final

    Inspected by Anthony Aslan

  22. Apr 15, 2021

    Passed: Building - Final

    Garage Doors Not Installed. Bonus Room Not Finished Out.

    Inspected by Anthony Aslan

Documents