Permit Details

Permit Search

Permit

New Residential Construction

291 SW OLD CYPRESS WAY
LAKE CITY, FL 32024

Permit #
000040511
Application #
47146
Status Completed
  1. Submitted —
  2. Issued Sep 10, 2020
  3. Expires Nov 2, 2021
  4. Completed May 6, 2021

Property

Parcel #
02439-131
Owner
Sorensen & Smith Llc
Acres
0.24
Subdivision
Reserve At Jewel Lake Phase 1
Zoning
PRD
Flood zone
X
District
3

Permit

Status
Completed
Septic release
Released
Related permit
—

Job Details

Elevation regulation
Subdivision Plat
Finished floor requirement
137'
Requirement needed
By Nailing Inspection
Document needed is
a Surveyor letter giving the Finished Floor Elevation
Document receieved
Yes
Fema map number
12023C0290D
In floodway
N
This is the construction of a
Single Family Dwelling
Setbacks Front
25'
Setback Side 1
10'
Setback Side 2
10'
Setbacks Rear
15'
Stories
1
Heated Area (Sqft)
1867
Total Area (Sqft)
2769
Building Height
23
Building Code Construction Type
V
Building Code Element
B
Building Code Occupancy Types
Residential
Occupancy Use Title
single family dwelling
Building Code Edition
Florida Building Code 2017 6th Edition & 2014 National Electrical Code
Septic# (00-0000) or (X00-000)
X-CITY

Status & Review History

  1. Point Review - Received-Hard Copy Application
  2. Point Review - Reviewed
  3. Zoning Review - Reviewed
  4. Plan Review - Reviewed
  5. Zoning Review - Reviewed
  6. Final Review - Payment Needed
  7. Permit Issued

Contractors

  • Gerald M Smith Sr

    S&s Construction,llc

    License
    CBC1254161
    Title
    Building Contractor
    Role
    Contractor

    County License & State License & Liability Insurance & Workers Comp Expired.

  • Lyndon J Rainbolt

    Rainbolt Tech Services,air Stream

    License
    EC13001835
    Title
    Electrical Contractor
    Role
    Subcontractor

    County License & State License & Workers Comp Expired.

  • Christopher Williams

    Christopher A Williams Inc Dba-country Comfort Heating & Ac

    License
    CAC057795
    Title
    Class "b" A/c
    Role
    Subcontractor

    County License & State License & Liability Insurance & Workers Comp Expired.

  • Daniel Mossburg

    Live Oak Plumbing, Inc.

    License
    CFC1427438
    Title
    Plumbing Contractor
    Role
    Subcontractor

    County License & State License & Liability Insurance & Workers Comp & Employees Workers Comp Expired.

  • Benjamin T Keeler

    Keeler Roofing, Llc

    License
    CCC1330509
    Title
    Cert. Roofing
    Role
    Subcontractor

Inspections

  1. Dec 18, 2020

    Failed: Building - Footer

    Not Ready Also Need Compaction Test

    Inspected by Troy Crews

  2. Dec 18, 2020

    Cancelled: Engineering - Setbacks

    Inspected by Troy Crews

  3. Dec 30, 2020

    Passed: Building - Footer

    Inspected by Troy Crews

  4. Dec 30, 2020

    Passed: Engineering - Setbacks

    Set By Surveyor

    Inspected by Troy Crews

  5. Jan 8, 2021

    Passed: Plumbing/Gas - 1st Underground Rough–In

    Inspected by Troy Crews

  6. Jan 11, 2021

    Passed: Building - Slab

    Inspected by Troy Crews

  7. Jan 29, 2021

    Passed: Building - Ext Strapping/Wall Sheathing

    Inspected by Troy Crews

  8. Jan 29, 2021

    Passed: Building - Roof Decking

    Inspected by Troy Crews

  9. Feb 4, 2021

    Passed: Plumbing/Gas - 2nd Rough-In

    Double Check Master Shower Pan Liner Leaked Down

    Inspected by Troy Crews

  10. Feb 10, 2021

    Failed: Mechanical - Rough In

    Dryer Duct Must Have Smooth Interior Finish Per. Code Section 504.8.1, Also 504.7 Requires Nail Plates For Duct. Need To Change Out To Smooth Metal Duct.

    Inspected by Troy Crews

  11. Feb 19, 2021

    Passed: Building - Framing

    Need To Nail Off Girder Tie Downs In Garage Will Check On Reinspection Of Hvac

    Inspected by Troy Crews

  12. Mar 1, 2021

    Passed: Building - Insulation

    Inspected by Troy Crews

  13. Apr 15, 2021

    Passed: Electrical - Permanent Power

    Need Platform For Service In Front Of Air Handler Prior To Final And Erosion Repair.

    Inspected by Troy Crews

  14. Apr 15, 2021

    Release to power company

    Inspected by Troy Crews

  15. Apr 23, 2021

    Passed: Mechanical - Rough In

    Items Corrected

    Inspected by Troy Crews

  16. May 6, 2021

    Passed: Building - Final

    Inspected by Troy Crews

Documents