Permit Details

Permit Search

Permit

Remodel

1476 SW WALTER AVE
LAKE CITY, FL 32024

Permit #
000040136
Application #
46489
Status Completed
  1. Submitted Jun 22, 2020
  2. Issued Jul 10, 2020
  3. Expires Sep 22, 2021
  4. Completed Mar 26, 2021

Property

Parcel #
03568-004
Owner
Belmont Academy, Inc
Acres
24.87
Subdivision
—
Zoning
A-3
Flood zone
X
District
5

Permit

Status
Completed
Septic release
Released
Related permit
—

Job Details

Elevation regulation
Existing Building
Finished floor requirement
Meet existing structure
Fema map number
12023C0383D
Type of Structure
Business
Commercial or Residential?
Commercial
Description of the work being performed:
AddING of A stairwell and interior
Septic#
x20
Building Code Construction Type
III
Building Code Element
B
Building Code Occupancy Types
Education
Occupancy Use Title
school
Dev Permit #
F023-
Building Code Edition
Florida Building Code 2017 6th Edition & 2014 National Electrical Code

Status & Review History

  1. Application pending.
  2. Point Review - Printed-Online Application
  3. Point Review - Processing
  4. Zoning Review - Reviewed
  5. Point Review - Reviewed
  6. Plan Review - Reviewed
  7. Final Review - Documents Required
  8. Final Review - Email Sent
  9. Final Review - Complete
  10. Final Review - Payment Needed
  11. Permit Issued

Contractors

  • Douglas W Wilcox Ii

    Scherer Construction Of N Fl Llc

    License
    CGC057622
    Title
    General Contractor
    Role
    Contractor

    County License & State License & Liability Insurance & Workers Comp Expired.

  • Mark A Ganskop

    Express Plumbing Inc

    License
    CFC1428040
    Title
    Plumbing Contractor
    Role
    Subcontractor
  • Lyndon J Rainbolt

    Rainbolt Tech Services,air Stream

    License
    EC13001835
    Title
    Electrical Contractor
    Role
    Subcontractor

    County License & State License & Workers Comp Expired.

  • Douglas Wilcox

    Scherer Construction Of North Florida Llc

    License
    CCC057419
    Title
    Cert. Roofing
    Role
    Subcontractor

    County License & State License & Liability Insurance & Workers Comp Expired.

Inspections

  1. Aug 14, 2020

    Rescheduled 8/17/2020:Building - Footer

    Inspected by Troy Crews

  2. Aug 14, 2020

    Rescheduled 8/17/2020:Engineering - Setbacks

    Inspected by Troy Crews

  3. Aug 17, 2020

    Passed: Building - Footer

    Inspected by Troy Crews

  4. Aug 17, 2020

    Passed: Engineering - Setbacks

    Inspected by Troy Crews

  5. Aug 26, 2020

    Passed: Building - Vertical Cells/Columns

    Stem Wall

    Inspected by Troy Crews

  6. Sep 4, 2020

    Passed: Building - Slab

    Inspected by Troy Crews

  7. Sep 28, 2020

    Passed: Building - Vertical Cells/Columns

    First Lift

    Inspected by Troy Crews

  8. Oct 9, 2020

    Passed: Building - Lintel/Tie Beam

    Tie Beam And Embeds For Floor Joist

    Inspected by Troy Crews

  9. Oct 23, 2020

    Passed: Building - Slab

    Metal Deck In Place For Floor

    Inspected by Troy Crews

  10. Dec 22, 2020

    Passed: Building - Roof Decking

    Partial

    Inspected by Troy Crews

  11. Jan 4, 2021

    Failed: Fire - Operational Test - Alarm System

    System Not Ready For Inspection

    Inspected by Tad Cervantes

  12. Jan 7, 2021

    Rescheduled 1/11/2021:Building - Roof Decking

    Inspected by Troy Crews

  13. Jan 11, 2021

    Passed: Building - Roof Decking

    Inspected by Troy Crews

  14. Jan 28, 2021

    Passed: Electrical - 2nd Rough-In

    Partial Surface Mount Items In Hallways

    Inspected by Troy Crews

  15. Jan 28, 2021

    Passed: Mechanical - Rough In

    Vav Units

    Inspected by Troy Crews

  16. Feb 17, 2021

    Passed: Building - Insulation

    Partial Hallway At Elevator

    Inspected by Troy Crews

  17. Feb 17, 2021

    Passed: Electrical - Above Ceiling

    Elevator Hallway

    Inspected by Troy Crews

  18. Feb 17, 2021

    Passed: Mechanical - Rough In

    Elevator Hallway

    Inspected by Troy Crews

  19. Feb 23, 2021

    Passed: Building - Insulation

    Elevator Hallway

    Inspected by Troy Crews

  20. Feb 23, 2021

    Passed: Electrical - Above Ceiling

    Elevator Lights In Elevator Hallway

    Inspected by Troy Crews

  21. Mar 26, 2021

    Passed: Building - Final

    Inspected by Troy Crews

Documents