132 SW FREEDOM CTFORT WHITE, FL 32038
William S Crawford
Stanley Crawford Construction, Inc.
County License & State License & Liability Insurance & Workers Comp & Employees Workers Comp Expired.
Kenneth Ault
Kenneth Edward Ault Plumbing Inc
Ralph W Laverdure
Rwl Roofing,llc.
County License & State License & Liability Insurance & Workers Comp Expired.
Ryan C Beville
Rbi Electrical Contracting Llc
Passed: Building - Footer
Inspected by Matt Forsyth
Passed: Engineering - Setbacks
Cancelled: Building - Slab
Inspected by Melissa Garber
Cancelled: Plumbing/Gas - 1st Underground Rough–In
Failed: Plumbing/Gas - 1st Underground Rough–In
No Water In 5' Stack.
Inspected by Tommy Matthews
Passed: Plumbing/Gas - 1st Underground Rough–In
Failed: Building - Slab
Missing Interior Footing
Passed: Building - Slab
Release to power company
Passed: Electrical - Temporary Service
Passed: Building - Roof Decking
Passed: Building - Wall Sheathing
Failed: Building - Framing
Beams And Headers Not Nailed Properly Need Fire Caulking In Top Plate. Posts Were Covered In Lap Siding Could Not Inspect Strapping Also Stud To Plate Connector 48"oc Missing
Passed: Mechanical - Rough In
Passed: Electrical - 2nd Rough-In
Passed: Building - Framing
Items Corrected Siding Taken Off Of Post Straps, Windstorm Osb To Take Place Of Sp Straps
Inspected by Troy Crews
Failed: Plumbing/Gas - 2nd Rough-In
Need Pressure On Water Lines Also Need To Install Nail Plates On 2 Inch Vent Through Roof Call Back In With Insulation
Passed: Plumbing/Gas - 2nd Rough-In
Passed: Building - Insulation
Septic Release Inspection
Inspected by Health Dept
Passed: Electrical - Permanent Power
Failed: Building - Final
Flexible Foil Duct Cant Be Concealed In Wall Or Attic, Install Metal Duct And Have Inspected Prior To Installing Concealment Trim
Need Blower Door And Final Termite Treatment
Building-Final
Termite And Blower Door Test Received
Passed: Building - Final