Permit Information

New Residential Construction Permit

Address 254 SW THISTLEWOOD LN
FORT WHITE, FL 32038
Parcel #: 04056-124
Acres:1.25
Owner:Terry Craig A & Lisa
Subdivision:Thornwood
Zoning:FORT WHITE
Flood Zone:X
District:2
Application #:44832
Permit #: 000039669
Related Permit:
Submitted:
Issued:Friday, April 24, 2020
Expires:Friday, January 15, 2021
Completed:Friday, January 15, 2021
Status: Completed
Septic Release? Yes

Notes

COMPLIANCE LETTER FROM THE TOWN OF FORT WHITE RECIEVED

Job Details

Finished floor requirement COMPLY WITH TOWN FORT WHITE REQUIREMENTS
Fema map number 12023C0490C
This is the construction of a Single Family Dwelling
Setbacks Front FORT WHITE
Setback Side 1 FORT WHITE
Setback Side 2 FORT WHITE
Setbacks Rear FORT WHITE
Stories 1
Heated Area (Sqft) 1844
Total Area (Sqft) 2694
Building Height 18
Building Code Construction Type V
Building Code Element B
Building Code Occupancy Types Residential
Occupancy Use Title single family
Building Code Edition Florida Building Code 2017 6th Edition & 2014 National Electrical Code
Septic# (00-0000) or (X00-000) 20-0219

Review Notes

3/26/2020 Point Review - Received
4/9/2020 Zoning Review - Completed/Sent for Final Review
4/24/2020 Permit Issued

Contractors

Name / Business License Title Role
Jeffrey P Bokor
Dwc Contracting, Inc.
CGC1517145 General Contractor Contractor
Ryan C Beville
Rbi Electrical Contracting Llc
EC13004236 Electrical Contractor Subcontractor
Samuel L Roberts
Air Ducks Inc
Liability Insurance Expired.
CAC1817288 Class "b" A/c Subcontractor
James Butler Jr
Butler Plumbing Of Gainesville Inc
CFC057960 Plumbing Contractor Subcontractor
Jeffrey Bokor
Dwc Contracting Llc
CCC1329756 Roofing Contractor Subcontractor

Inspections

Inspection Notes Performed By Date
Passed: Building - Footer Organic Material Must Be Removed Prior To Fill. We Require That We Inspect Before Fill Is Installed. Need Porto Potti Prior To Next Inspection. Tommy Matthews 4/30/2020
Passed: Engineering - Setbacks Tommy Matthews 4/30/2020
Passed: Building - Footer Matt Forsyth 5/11/2020
Passed: Engineering - Setbacks Matt Forsyth 5/11/2020
Passed: Plumbing/Gas - 1st Underground Rough–In Tommy Matthews 5/14/2020
Passed: Building - Slab Matt Forsyth 5/15/2020
Passed: Electrical - Temporary Service Tommy Matthews 5/20/2020
Release to power company Tommy Matthews 5/20/2020
Passed: Building - Roof Decking Tommy Matthews 5/28/2020
Passed: Building - Wall Sheathing Tommy Matthews 5/28/2020
Release to power company Changed Power Company From Duke To Clay Laurie Hodson 6/2/2020
Failed: Building - Strapping All Headers Spaning 12 Feet Plus Need To Be Pre-engineered. See Garage Door Header And Back Porch Header. See Note 7. all Headers Should Have At Least 2 Full Length Studs At Each End Of Headers. Garage Door Should Have 4. spacing Of Porch Columns Shall Not Exceed 9 Foot 6 Inch. according To Drawing, Opening Should Have Min. Of 2 Jack Stuck. south End Of Trusses A1gir, A-2, A-3 & A-4 Has No Clip. seal Hole In Floor Below Gaeden Tub Tommy Matthews 6/12/2020
Passed: Electrical - 2nd Rough-In See Adendum From Engineer On Updated Reg's For Headers. Rec'd 6/22/20 Tommy Matthews 6/12/2020
Passed: Mechanical - Rough In Tommy Matthews 6/12/2020
Failed: Plumbing/Gas - 2nd Rough-In Seal Hole Under Garden Tub Tommy Matthews 6/12/2020
Passed: Plumbing/Gas - 2nd Rough-In Tommy Matthews 6/24/2020
Passed: Building - Insulation Tommy Matthews 6/24/2020
Failed: Building - Framing South End Of Trusses A1gir, A-2, A-3 & A-4 Has No Clips. Tommy Matthews 6/24/2020
Passed: Building - Framing Tommy Matthews 6/24/2020
Septic Release Inspection Health Dept 8/21/2020
Passed: Electrical - Permanent Power Troy Crews 8/31/2020
Release to power company Troy Crews 8/31/2020
Failed: Building - Final Missing Blower Door Test And Final Termite Treatment Matt Forsyth 1/15/2021
Passed: Building - Final Blower Door Received And Termite Treatment Matt Forsyth 1/15/2021

Contact Us

Building Department

Office Hours

Monday-Friday
8:00 A.M. - 4:30 P.M.

Contact Information

Phone: 386-758-1008
Fax: 386-758-2160

Email: bldginfo@columbiacountyfla.com

Location

135 NE Hernando Ave.
Lake City, FL 32055 (opens in new window)

Mailing Address

P.O. Box 1529
Lake City, FL 32056-1529

Public Records

Public records policy and fees

Board of County Commissioners
Tel. (386) 758-1326
Fax: (386) 758-2182
Email: publicrecords@columbiacountyfla.com

Mailing Address:
P.O. Box 1529
Lake City, FL 32056-1529

Citizen Feedback

Let us know how we're doing

ADA Accessibility

Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the Columbia County ADA Coordinator at (386) 758-3344. You may also email that office at hr@columbiacountyfla.com and provide a brief description of the inaccessible feature.

Columbia County strives to provide reasonable accommodations to help people with disabilities have an equal opportunity to participate in our public meetings. Please notify our ADA Coordinator at least 48 hours prior to the public meeting by calling (386) 758-3344.