Permit Details

Permit Search

Permit

New Residential Construction

154 NW GOBBLER DR
LAKE CITY, FL 32055

Permit #
000039485
Application #
44530
Status Completed
  1. Submitted —
  2. Issued Mar 26, 2020
  3. Expires Mar 14, 2021
  4. Completed Sep 15, 2020

Property

Parcel #
02279-125
Owner
Don Little Construction & Roofing, Inc.
Acres
0.33
Subdivision
Turkey Creek Unit 1
Zoning
PRD
Flood zone
X
District
1

Permit

Status
Completed
Septic release
Released
Related permit
—

Job Details

Elevation regulation
Engineers Elevation Letter
Finished floor requirement
158.12'
Requirement needed
By Nailing Inspection
Document needed is
a Surveyor letter giving the Finished Floor Elevation
Document receieved
Yes
Fema map number
12023C0283D
In floodway
N
This is the construction of a
Single Family Dwelling
Setbacks Front
20
Setback Side 1
10
Setback Side 2
10
Setbacks Rear
20
Stories
1
Heated Area (Sqft)
1654
Total Area (Sqft)
2521
Building Height
20
Building Code Construction Type
V
Building Code Element
B
Building Code Occupancy Types
Residential
Occupancy Use Title
Single family
Building Code Edition
Florida Building Code 2017 6th Edition & 2014 National Electrical Code
Septic# (00-0000) or (X00-000)
20-0158

Status & Review History

  1. Point Review - Received
  2. Zoning Review - Completed/Sent for Final Review
  3. Permit Issued
  4. Permit reissued to reflect updated information.

Contractors

  • Donald E Little Jr

    Don Little Construction & Roofing, Inc.

    License
    CBC1260286
    Title
    Cert. Building
    Role
    Contractor

    County License & State License Expired.

  • Stephen M Brisbois

    Epic Ac Service

    License
    CAC1819412
    Title
    Cert. A/c Class “b”
    Role
    Subcontractor
  • Daniel Mossburg

    Live Oak Plumbing, Inc.

    License
    CFC1427438
    Title
    Plumbing Contractor
    Role
    Subcontractor

    County License & State License & Liability Insurance & Workers Comp & Employees Workers Comp Expired.

  • Donald Little, Jr.

    Don Little Construction & Roofing, Inc.

    License
    CCC1330420
    Title
    Cert. Roofing
    Role
    Subcontractor

    County License & State License Expired.

Inspections

  1. Apr 3, 2020

    Passed: Plumbing/Gas - 1st Underground Rough–In

    We Need Engineer Floor Elevation Letter

    Inspected by Troy Crews

  2. Apr 9, 2020

    Passed: Building - Slab

    Inspected by Troy Crews

  3. Apr 9, 2020

    Passed: Electrical - Temporary Service

    Inspected by Troy Crews

  4. Apr 9, 2020

    Release to power company

    Inspected by Troy Crews

  5. May 18, 2020

    Passed: Building - Roof Decking

    Inspected by Troy Crews

  6. May 18, 2020

    Passed: Building - Wall Sheathing

    Inspected by Troy Crews

  7. May 20, 2020

    Cancelled: Building - Ext Strapping/Wall Sheathing

    Already Done, Elevation Letter Rec'd

    Inspected by Troy Crews

  8. Jun 5, 2020

    Passed: Plumbing/Gas - 2nd Rough-In

    Inspected by Troy Crews

  9. Jun 5, 2020

    Passed: Electrical - 2nd Rough-In

    Inspected by Troy Crews

  10. Jun 5, 2020

    Passed: Mechanical - Rough In

    Inspected by Troy Crews

  11. Jun 23, 2020

    Failed: Building - Framing

    Need To Complete Strapping Of All Window Headers, All Openings Over 6 Feet Call For 2 Jacks Two Kings Need To Compete Or Get Letter From Architect Approving Only 1 King Stud.

    Inspected by Troy Crews

  12. Jun 25, 2020

    Rescheduled 6/26/2020:Building - Framing

    Inspected by Troy Crews

  13. Jun 29, 2020

    Passed: Building - Framing

    Inspected by Troy Crews

  14. Jun 29, 2020

    Passed: Building - Insulation

    Inspected by Troy Crews

  15. Sep 8, 2020

    Release to power company

    Rec'd. Eh

    Inspected by Troy Crews

  16. Sep 8, 2020

    Passed: Electrical - Permanent Power

    Need Final Septic

    Inspected by Troy Crews

  17. Sep 9, 2020

    Release to power company

    Inspected by Laurie Hodson

  18. Sep 9, 2020

    Septic Release Inspection

    Inspected by Health Dept

  19. Sep 11, 2020

    Failed: Building - Final

    Need Permanent Power Meter Installed For Final

    Inspected by Troy Crews

  20. Sep 15, 2020

    Passed: Building - Final

    Inspected by Troy Crews