Permit Details

Permit Search

Permit

New Residential Construction

315 SW ARROWBEND DR
LAKE CITY, FL 32024

Permit #
000039030
Application #
44097
Status Completed
  1. Submitted —
  2. Issued Dec 12, 2019
  3. Expires Mar 10, 2021
  4. Completed Sep 11, 2020

Property

Parcel #
03114-127
Owner
Bradley Franks Construction Llc
Acres
0.50
Subdivision
Cannon Creek Place
Zoning
RSF-2
Flood zone
X
District
3

Permit

Status
Completed
Septic release
Released
Related permit
—

Job Details

Finished floor requirement
99' PER PLAT
Fema map number
12023C0381D
In floodway
N
This is the construction of a
Single Family Dwelling
Setbacks Front
25
Setback Side 1
10
Setback Side 2
10
Setbacks Rear
15
Stories
1
Heated Area (Sqft)
1614
Total Area (Sqft)
2328
Building Height
18
Building Code Construction Type
V
Building Code Element
B
Building Code Occupancy Types
Residential
Occupancy Use Title
single family
Building Code Edition
Florida Building Code 2017 6th Edition & 2014 National Electrical Code
Septic# (00-0000) or (X00-000)
18-0548

Status & Review History

  1. Point Review - Received
  2. Permit Issued

Contractors

  • Bradley Franks

    Bradley Franks Construction, Llc

    License
    RG291103874
    Title
    General Cotractor
    Role
    Contractor

    County License & State License & Workers Comp Expired.

  • David E Hall

    David Hall's Air Cond & Heating Svc,inc.

    License
    CAC057424
    Title
    Class B A/c Contractor
    Role
    Subcontractor

    Workers Comp Expired.

  • Cody Barrs

    Barrs Plumbing,inc.

    License
    CFC1427145
    Title
    Plumbing Contractor
    Role
    Subcontractor
  • Oscar Gray

    Dependable Heating A/c & Electrical Contractor

    License
    EC0001471
    Title
    Electrical Contractor
    Role
    Subcontractor

    County License & State License & Liability Insurance & Workers Comp & Employees Workers Comp Expired.

Inspections

  1. Dec 13, 2019

    Passed: Plumbing/Gas - 1st Underground Rough–In

    Inspected by Matt Forsyth

  2. Dec 17, 2019

    Passed: Building - Slab

    Inspected by Matt Forsyth

  3. Dec 30, 2019

    Passed: Electrical - Temporary Service

    Inspected by Troy Crews

  4. Dec 30, 2019

    Release to power company

    Inspected by Troy Crews

  5. Jan 6, 2020

    Passed: Building - Ext Strapping/Wall Sheathing

    Wall Strapping Not Installed. Will Look At It At Roof Sheathing Inspection. No More Scheduled Inspections Permitted Until Elevation Confirmation Letter Received And Approved.

    Inspected by Tommy Matthews

  6. Jan 23, 2020

    Passed: Building - Roof Decking

    Inspected by Tommy Matthews

  7. Feb 5, 2020

    Passed: Building - Framing

    Inspected by Matt Forsyth

  8. Feb 25, 2020

    Passed: Electrical - 2nd Rough-In

    Inspected by Tommy Matthews

  9. Feb 25, 2020

    Failed: Mechanical - Rough In

    Exhaust Fan In Master Bath Not Ducted (toilet Area).

    Inspected by Tommy Matthews

  10. Feb 25, 2020

    Passed: Plumbing/Gas - 2nd Rough-In

    Inspected by Tommy Matthews

  11. Mar 4, 2020

    Passed: Mechanical - Rough In

    Inspected by Tommy Matthews

  12. Mar 4, 2020

    Passed: Building - Insulation

    Inspected by Tommy Matthews

  13. May 21, 2020

    Failed: Electrical - Permanent Power

    Need Garage Door Installed For Safety. Panel Box In Garage. Need Septic Final. Could Not Get Access To Inside For Inspection.

    Inspected by Tommy Matthews

  14. May 29, 2020

    Septic Release Inspection

    Inspected by Health Dept

  15. Jun 3, 2020

    Passed: Electrical - Permanent Power

    Need Culvert Final

    Inspected by Tommy Matthews

  16. Jun 24, 2020

    Release to power company

    Inspected by Tommy Matthews

  17. Aug 28, 2020

    Failed: Building - Final

    Showers Not Working And Final Termite Document-rec'd Termite 9/9/20

    Inspected by Matt Forsyth

  18. Sep 11, 2020

    Passed: Building - Final

    Inspected by Matt Forsyth