Permit Information

New Commercial Construction Permit

Address 277 NW BROWN RD
LAKE CITY, FL 32055
Parcel #: 02435-001
Acres:5.00
Owner:Haddox Mark
Subdivision:
Zoning:CI
Flood Zone:X
District:3
Application #:43776
Permit #: 000038899
Related Permit:
Submitted:Friday, October 11, 2019
Issued:Thursday, November 14, 2019
Expires:Thursday, April 2, 2020
Completed:Thursday, April 2, 2020
Status: Completed
Septic Release? Yes

Notes

SDP 1906, MINIMUM FLOOR ELEVATION PER SITE PLAN IS 167.25' , NEED AN ELEVATION CONFIRMATION LETTER AT SLAB ADDITIONAL PERMIT REQUIRED FOR INTERIOR BUILD-OUT ELEVATION LETTER RECEIVED AT 168.83

Job Details

Finished floor requirement
Fema map number 12023C0280D
This is the construction of a: repair shop and office METAL BUILDING SHELL
Driveway access to property: Existing Drive
Is there a Fire Sprinkler System? No
Setbacks Front 20
Setback Side 1 5
Setback Side 2 5
Setback Rear 15
Stories 1
Heated Area (Sqft) 1440
Total Area (Sqft) 10760
Building Height 18
Building Code Construction Type III
Building Code Element B
Building Code Occupancy Types Business
Occupancy Use Title commercial
Dev Permit # F023-
Design Occupant Load 108 total
Building Code Edition Florida Building Code 2017 6th Edition & 2014 National Electrical Code
Septic# (00-0000) or (X00-000) 19-0765

Review Notes

10/30/2019 Plan Review - Completed/Sent for Zoning Review
10/30/2019 Zoning Review - Completed/Sent for Final Review
11/13/2019 Point Review - Completed/Sent for Plan Review
11/13/2019 Point Review - Completed/Sent for Plan Review
11/14/2019 Permit Issued
12/31/2019 Point Review - Completed/Sent for Plan Review

Contractors

Name / Business License Title Role
Robert Parrish
P C Quality Metal Construction, Inc. (union Lasteel Metal Buildings)
CBC059948 Building Contractor Contractor
David E Hall
David Hall's Air Cond & Heating Svc,inc.
Liability Insurance Expired.
CAC057424 Class B A/c Contractor Subcontractor
Marcus Matthews
Matthews Electric Llc
EC13005459 Electrical Contractor Subcontractor

Inspections

Inspection Notes Performed By Date
Passed: Plumbing/Gas - 1st Underground Rough–In Troy Crews 12/17/2019
Passed: Building - Footer Install Ground On Footer Steel Prior To Pour Troy Crews 1/8/2020
Passed: Engineering - Setbacks Troy Crews 1/8/2020
Passed: Building - Monolithic Slab Troy Crews 1/8/2020
Passed: Building - Final Steel Building Shell Only Troy Crews 4/2/2020
Passed: Building - Framing Troy Crews 4/2/2020
Septic Release Inspection Health Dept 4/15/2021

Contact Us

Building Department

Office Hours

Monday-Friday
8:00 A.M. - 4:30 P.M.

Contact Information

Phone: 386-758-1008
Fax: 386-758-2160

Email: bldginfo@columbiacountyfla.com

Location

135 NE Hernando Ave.
Lake City, FL 32055 (opens in new window)

Mailing Address

P.O. Box 1529
Lake City, FL 32056-1529

Public Records

Public records policy and fees

Board of County Commissioners
Tel. (386) 758-1326
Fax: (386) 758-2182
Email: publicrecords@columbiacountyfla.com

Mailing Address:
P.O. Box 1529
Lake City, FL 32056-1529

Citizen Feedback

Let us know how we're doing

ADA Accessibility

Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the Columbia County ADA Coordinator at (386) 758-3344. You may also email that office at hr@columbiacountyfla.com and provide a brief description of the inaccessible feature.

Columbia County strives to provide reasonable accommodations to help people with disabilities have an equal opportunity to participate in our public meetings. Please notify our ADA Coordinator at least 48 hours prior to the public meeting by calling (386) 758-3344.