Permit Details

Permit Search

Permit

New Residential Construction

237 SW HILL CREEK DR
LAKE CITY, FL 32025

Permit #
000038531
Application #
42492
Status Completed
  1. Submitted Aug 27, 2019
  2. Issued Aug 27, 2019
  3. Expires Oct 27, 2020
  4. Completed Apr 30, 2020

Property

Parcel #
09116-130
Owner
Donnie & Sheila Blackwell
Acres
5.00
Subdivision
Hills At Rose Creek
Zoning
A-3
Flood zone
X
District
4

Permit

Status
Completed
Septic release
Released
Related permit
—

Job Details

Finished floor requirement
Fema map number
12023C0384D
This is the construction of a
SFD/UTILITY
Setbacks Front
30.00
Setback Side 1
25.00
Setback Side 2
25.00
Setbacks Rear
25.00
Stories
1
Heated Area (Sqft)
2598.00
Total Area (Sqft)
3363.00
Building Code Edition
Florida Building Code 2017 6th Edition & 2014 National Electrical Code
Septic# (00-0000) or (X00-000)
19-0609

Status & Review History

No status updates yet.

Contractors

  • Max Bass

    License
    R282811195
    Title
    —
    Role
    —

    County License & State License Expired.

Inspections

  1. Sep 18, 2019

    Passed: Building - Footer

    Need Compaction Test On Fill Areas

    Inspected by Troy Crews

  2. Sep 18, 2019

    Passed: Engineering - Setbacks

    Inspected by Troy Crews

  3. Sep 18, 2019

    Passed: Electrical - Temporary Service

    Inspected by Troy Crews

  4. Sep 18, 2019

    Release to power company

    Inspected by Troy Crews

  5. Oct 23, 2019

    Passed: Plumbing/Gas - 1st Underground Rough–In

    Inspected by Matt Forsyth

  6. Oct 29, 2019

    Passed: Building - Slab

    Inspected by Troy Crews

  7. Nov 5, 2019

    Passed: Building - Slab

    Inspected by Troy Crews

  8. Dec 13, 2019

    Passed: Building - Ext Strapping/Wall Sheathing

    Inspected by Matt Forsyth

  9. Feb 5, 2020

    Failed: Building - Framing

    Porch Posts Do Not Have Required Lsta24 Installed. porch Ceiling Must Be Sheathed W/min 3/8” Osb. 2-2x4 Required Under D2gir Truss. new Opening For Door Not Shown For Right Rear Bedroom. Must Have Engineer Account For This In Design. See S-3. window Below Truss D7gir Requires 2 King Studs. truss F3gir Requires 3-2x4 Centered Under Each End. truss C1gir Needs 2-2x4 Centered Under Each End Of Truss. anchor Bolts Required Within 6” Each Side Of Plate Joint. truss C4, C5, C6, And C7 Missing Engineering Brace.

    Inspected by Tommy Matthews

  10. Feb 5, 2020

    Passed: Electrical - 2nd Rough-In

    Inspected by Tommy Matthews

  11. Feb 5, 2020

    Passed: Mechanical - Above Ceiling

    Inspected by Tommy Matthews

  12. Feb 5, 2020

    Failed: Plumbing/Gas - 2nd Rough-In

    Seal Hole Under Fiberglass Tub On Right Side Of House.

    Inspected by Tommy Matthews

  13. Feb 5, 2020

    Failed: Building - Roof Decking

    Remove Shiner On Left Rear Hip. Renail At That Location.

    Inspected by Tommy Matthews

  14. Feb 7, 2020

    Passed: Building - Framing

    Install 3/8” Osb On Ceiling Of Back Porch.

    Inspected by Tommy Matthews

  15. Feb 7, 2020

    Failed: Plumbing/Gas - 2nd Rough-In

    See Picture Attached

    Inspected by Tommy Matthews

  16. Feb 10, 2020

    Passed: Plumbing/Gas - 2nd Rough-In

    Inspected by Tommy Matthews

  17. Feb 18, 2020

    Passed: Building - Insulation

    Inspected by Troy Crews

  18. Apr 13, 2020

    Septic Release Inspection

    Inspected by Health Dept

  19. Apr 13, 2020

    Passed: Electrical - Permanent Power

    Inspected by Troy Crews

  20. Apr 13, 2020

    Release to power company

    Inspected by Troy Crews

  21. Apr 30, 2020

    Passed: Building - Final

    Inspected by Tommy Matthews