Permit Details

Permit Search

Permit

New Residential Construction

168 SW OLD CYPRESS WAY
LAKE CITY, FL 32024

Permit #
000038242
Application #
42023
Status Completed
  1. Submitted Jun 17, 2019
  2. Issued Jun 17, 2019
  3. Expires May 2, 2020
  4. Completed Nov 4, 2019

Property

Parcel #
02439-118
Owner
Gary Sorensen
Acres
0.28
Subdivision
The Reserve At Jewel Lake
Zoning
PRD
Flood zone
X
District
3

Permit

Status
Completed
Septic release
Released
Related permit
—

Job Details

Finished floor requirement
Fema map number
12023C0290D
This is the construction of a
SFD, UTILITY
Setbacks Front
25.00
Setback Side 1
10.00
Setback Side 2
10.00
Setbacks Rear
15.00
Stories
1
Heated Area (Sqft)
1453.00
Total Area (Sqft)
2195.00
Building Code Edition
Florida Building Code 2017 6th Edition & 2014 National Electrical Code
Septic# (00-0000) or (X00-000)
X-CITY

Status & Review History

No status updates yet.

Contractors

  • Gerald Smith Sr

    License
    CBC1254161
    Title
    —
    Role
    —

    County License & State License & Liability Insurance & Workers Comp Expired.

Inspections

  1. Jun 25, 2019

    Passed: Building - Footer

    Inspected by Troy Crews

  2. Jun 25, 2019

    Passed: Engineering - Setbacks

    Inspected by Troy Crews

  3. Jul 9, 2019

    Passed: Plumbing/Gas - Underground Rough-In

    Inspected by Troy Crews

  4. Jul 10, 2019

    Passed: Building - Slab

    Inspected by Troy Crews

  5. Jul 30, 2019

    Passed: Building - Roof Decking

    Inspected by Troy Crews

  6. Jul 30, 2019

    Passed: Building - Ext Strapping/Wall Sheathing

    Inspected by Troy Crews

  7. Jul 30, 2019

    Passed: Plumbing/Gas - Rough In

    Inspected by Troy Crews

  8. Jul 30, 2019

    Passed: Electrical - Rough In

    Inspected by Troy Crews

  9. Aug 2, 2019

    Passed: Building - Framing

    Inspected by Troy Crews

  10. Aug 19, 2019

    Failed: Mechanical - Rough In

    Supply Vents Within 3 Ft. Of Smoke Detector 2 South Bedrooms

    Inspected by Troy Crews

  11. Aug 21, 2019

    Passed: Building - Insulation

    Inspected by Troy Crews

  12. Aug 21, 2019

    Passed: Mechanical - Rough In

    Smoke Detectors Moved Away From Air Supply Grill

    Inspected by Troy Crews

  13. Sep 4, 2019

    Cancelled: Electrical - Permanent Power

    Inspected by Laurie Hodson

  14. Sep 6, 2019

    Release to power company

    Resent To Fpl

    Inspected by Tc

  15. Sep 6, 2019

    Passed: Electrical - Permanent Power

    Inspected by Troy Crews

  16. Nov 4, 2019

    Passed: Building - Final

    Release Pending Blower Door Test

    Inspected by Troy Crews