Permit Information

New Residential Construction Permit

Address 315 SW NEWLYWED CT
LAKE CITY, FL 32024
Parcel #: 02973-113
Acres:0.50
Owner:Bullard Mgmt Services Inc
Subdivision:Hunnington Place
Zoning:RSF-2
Flood Zone:X
District:3
Application #:40384
Permit #: 000037800
Related Permit:
Submitted:Tuesday, February 26, 2019
Issued:Tuesday, February 26, 2019
Expires:Monday, August 19, 2019
Completed:Monday, August 19, 2019
Status: Completed
Septic Release? Yes

Notes

PER ENGINEERS LETTER ON PLAT MINIMUM FLOOR ELEVATION IS 101.00', 6/17/19 UPDATED ENGINEER'S LETTER STATES MFE IS 97.50 FOR LOT 13 - COPY SCANNED INTO FILE, NEED ELEVATION LETTER ON HEIGHT AND INCLUDE SPECIFIC GRADING PLAN TO SHOW DRAINAGE AWAY FROM LOWER ELEVATION ADJACENT LOTS, NOC ON FILE, ELEVATION LETTER REC'D AT 110.78', REC'D EMAIL FROM ENGINEER THAT SITE WAS GRADED PER THE TERMS OF HIS LETTER.

Job Details

Finished floor requirement
Fema map number 12023C0293D
This is the construction of a SFD, UTILITY
Setbacks Front 25.00
Setback Side 1 10.00
Setback Side 2 10.00
Setbacks Rear 15.00
Stories 1
Heated Area (Sqft) 1744.00
Total Area (Sqft) 2509.00
Building Code Edition Florida Building Code 2017 6th Edition & 2014 National Electrical Code
Septic# (00-0000) or (X00-000) 18-0536

Review Notes

Contractors

Name / Business License Title Role
Adam Papka

County License & State License & Liability Insurance & Workers Comp Expired.
CBC1253409

Inspections

Inspection Notes Performed By Date
Passed: Plumbing/Gas - Underground Rough-In Troy Crews 2/28/2019
Passed: Building - Slab Tommy Matthews 3/4/2019
Passed: Electrical - Footer Steel & Grounding Tommy Matthews 3/4/2019
Passed: Building - Ext Strapping/Wall Sheathing Troy Crews 3/28/2019
Passed: Building - Roof Decking Troy Crews 3/29/2019
Passed: Building - Framing Troy Crews 4/17/2019
Passed: Electrical - Rough In Troy Crews 4/17/2019
Passed: Mechanical - Rough In Troy Crews 4/17/2019
Passed: Plumbing/Gas - Rough In Troy Crews 4/17/2019
Failed: Building - Insulation Need Elevation Letter Tommy Matthews 4/22/2019
Passed: Building - Insulation Elevation Letter Rec'd Tommy Matthews 6/17/2019
Septic Release Inspection Health Dept 6/18/2019
Passed: Electrical - Permanent Power All Elevation Letters And Engineer's Approvals Rec'd Troy Crews 6/19/2019
Release to power company Troy Crews 6/19/2019
Passed: Building - Final Need Blower Door Test Results, Rec'd 8/19/19 Tommy Matthews 6/27/2019

Contact Us

Building Department

Office Hours

Monday-Friday
8:00 A.M. - 4:30 P.M.

Contact Information

Phone: 386-758-1008
Fax: 386-758-2160

Email: bldginfo@columbiacountyfla.com

Location

135 NE Hernando Ave.
Lake City, FL 32055 (opens in new window)

Mailing Address

P.O. Box 1529
Lake City, FL 32056-1529

Public Records

Public records policy and fees

Board of County Commissioners
Tel. (386) 758-1326
Fax: (386) 758-2182
Email: publicrecords@columbiacountyfla.com

Mailing Address:
P.O. Box 1529
Lake City, FL 32056-1529

Citizen Feedback

Let us know how we're doing

ADA Accessibility

Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the Columbia County ADA Coordinator at (386) 758-3344. You may also email that office at hr@columbiacountyfla.com and provide a brief description of the inaccessible feature.

Columbia County strives to provide reasonable accommodations to help people with disabilities have an equal opportunity to participate in our public meetings. Please notify our ADA Coordinator at least 48 hours prior to the public meeting by calling (386) 758-3344.