Permit Details

Permit Search

Permit

New Residential Construction

529 SW LITTLE RD
LAKE CITY, FL 32055

Permit #
000037718
Application #
40254
Status Completed
  1. Submitted Feb 6, 2019
  2. Issued Feb 6, 2019
  3. Expires Jan 28, 2020
  4. Completed Aug 6, 2019

Property

Parcel #
09144-006
Owner
Robert Evans, Jr. & Laura L. Evans
Acres
20.33
Subdivision
—
Zoning
A-3
Flood zone
X
District
5

Permit

Status
Completed
Septic release
Released
Related permit
—

Job Details

Finished floor requirement
Fema map number
12023C0383D
This is the construction of a
SFD/UTILITY
Setbacks Front
30.00
Setback Side 1
25.00
Setback Side 2
25.00
Setbacks Rear
25.00
Stories
1
Heated Area (Sqft)
2295.00
Total Area (Sqft)
3503.00
Building Code Edition
Florida Building Code 2017 6th Edition & 2014 National Electrical Code
Septic# (00-0000) or (X00-000)
19-0059

Status & Review History

No status updates yet.

Contractors

  • Kevin L. Bedebaugh, Jr.

    License
    CGC1516042
    Title
    —
    Role
    —

Inspections

  1. Feb 18, 2019

    Passed: Building - Footer

    Inspected by Troy Crews

  2. Feb 18, 2019

    Passed: Engineering - Setbacks

    Inspected by Troy Crews

  3. Feb 19, 2019

    Passed: Electrical - Temporary Service

    Inspected by Troy Crews

  4. Mar 1, 2019

    Release to power company

  5. Mar 1, 2019

    Passed: Plumbing/Gas - Underground Rough-In

    Toilet Rough 10 1/2

    Inspected by Matt Forsyth

  6. Mar 6, 2019

    Failed: Building - Slab

    No Address On Termite Trement. Toilet Roughin Needs To Be 12 Inches

    Inspected by Matt Forsyth

  7. Mar 8, 2019

    Passed: Building - Slab

    Termite Doc Rec.

    Inspected by Matt Forsyth

  8. Mar 28, 2019

    Failed: Building - Ext Strapping/Wall Sheathing

    Walls Not Finished

    Inspected by Matt Forsyth

  9. Mar 29, 2019

    Passed: Building - Ext Strapping/Wall Sheathing

    Inspected by Matt Forsyth

  10. Apr 5, 2019

    Passed: Electrical - Rough In

    Inspected by Tommy Matthews

  11. Apr 5, 2019

    Passed: Mechanical - Rough In

    Inspected by Tommy Matthews

  12. Apr 5, 2019

    Passed: Plumbing/Gas - Rough In

    Inspected by Tommy Matthews

  13. Apr 5, 2019

    Failed: Building - Framing

    Plans Sheet 5 Of 9 Anchor Bolts Should Be 5/8”, 3’ Spacing sheet 6 Of 9 Need Another Strap Top And Bottom At Rear Door On To Porch left Side Of Home Does Not Have Required Strapping Gable Truss To Exterior Wall trusses b05 Missing Bracing

    Inspected by Tommy Matthews

  14. Apr 18, 2019

    Passed: Building - Framing

    Items Corrected Per Engineer Letter

    Inspected by Troy Crews

  15. Apr 29, 2019

    Passed: Building - Insulation

    Inspected by Troy Crews

  16. Jul 18, 2019

    Passed: Electrical - Permanent Power

    Need Septic And Drive To Release Power

    Inspected by Matt Forsyth

  17. Jul 19, 2019

    Release to power company

    Inspected by Lh

  18. Jul 19, 2019

    Septic Release Inspection

    Inspected by Health Dept

  19. Aug 1, 2019

    Passed: Building - Final

    Inspected by Troy Crews