Permit Details

Permit Search

Permit

New Residential Construction

302 SW NEWLYWED CT
LAKE CITY, FL 32024

Permit #
000037683
Application #
40210
Status Completed
  1. Submitted Jan 25, 2019
  2. Issued Jan 25, 2019
  3. Expires Oct 27, 2019
  4. Completed May 24, 2019

Property

Parcel #
02973-109
Owner
Bullard Management Services
Acres
0.50
Subdivision
Hunnington Place
Zoning
RSF-2
Flood zone
X
District
3

Permit

Status
Completed
Septic release
Released
Related permit
—

Job Details

Finished floor requirement
Fema map number
12023C0293D
This is the construction of a
SFD, UTILITY
Setbacks Front
25.00
Setback Side 1
10.00
Setback Side 2
10.00
Setbacks Rear
15.00
Stories
1
Heated Area (Sqft)
1649.00
Total Area (Sqft)
2369.00
Building Code Edition
Florida Building Code 2017 6th Edition & 2014 National Electrical Code
Septic# (00-0000) or (X00-000)
18-0537

Status & Review History

No status updates yet.

Contractors

  • Adam Papka

    License
    CBC1253409
    Title
    —
    Role
    —

    County License & State License & Liability Insurance & Workers Comp Expired.

Inspections

  1. Feb 13, 2019

    Cancelled: Building - Monolithic Slab

    Inspected by Tommy Matthews

  2. Feb 14, 2019

    Passed: Engineering - Setbacks

    Inspected by Tommy Matthews

  3. Feb 14, 2019

    Passed: Electrical - Temporary Service

    Inspected by Tommy Matthews

  4. Feb 14, 2019

    Passed: Plumbing/Gas - Underground Rough-In

    Inspected by Tommy Matthews

  5. Feb 15, 2019

    Passed: Building - Monolithic Slab

    Inspected by Troy Crews

  6. Feb 15, 2019

    Passed: Engineering - Setbacks

    Inspected by Troy Crews

  7. Feb 19, 2019

    Release to power company

    Inspected by Laurie Hodson

  8. Mar 8, 2019

    Passed: Building - Roof Decking

    Inspected by Tommy Matthews

  9. Mar 8, 2019

    Passed: Building - Ext Strapping/Wall Sheathing

    Inspected by Tommy Matthews

  10. Mar 8, 2019

    Failed: Building - Framing

    Not Complete

    Inspected by Tommy Matthews

  11. Mar 21, 2019

    Passed: Building - Framing

    Inspected by Troy Crews

  12. Mar 21, 2019

    Passed: Electrical - Rough In

    Inspected by Troy Crews

  13. Mar 21, 2019

    Passed: Mechanical - Rough In

    Inspected by Troy Crews

  14. Mar 21, 2019

    Passed: Plumbing/Gas - Rough In

    Inspected by Troy Crews

  15. Mar 25, 2019

    Passed: Building - Insulation

    Seal End Of False Beam In Dining Room. Send Picture.

    Inspected by Tommy Matthews

  16. Apr 17, 2019

    Passed: Electrical - Permanent Power

    Need Health Release

    Inspected by Troy Crews

  17. Apr 22, 2019

    Release to power company

    Inspected by Lh

  18. Apr 22, 2019

    Septic Release Inspection

    Inspected by Health Dept

  19. Apr 30, 2019

    Passed: Building - Final

    Termite Cert Rec'd

    Inspected by Tommy Matthews