Permit Details

Permit Search

Permit

New Residential Construction

3431 SW CUSTOM MADE CIRCLE
LAKE CITY, FL 32024

Permit #
000037590
Application #
40086
Status Completed
  1. Submitted Jan 3, 2019
  2. Issued Jan 3, 2019
  3. Expires May 31, 2020
  4. Completed Dec 5, 2019

Property

Parcel #
09280-102
Owner
Jon Les & Kimberly Haskew
Acres
4.74
Subdivision
The Oaks Of Lake City
Zoning
AG-3
Flood zone
X
District
5

Permit

Status
Completed
Septic release
Released
Related permit
—

Job Details

Finished floor requirement
Fema map number
12023C0395C
This is the construction of a
SFD, UTILITY
Setbacks Front
30.00
Setback Side 1
25.00
Setback Side 2
25.00
Setbacks Rear
25.00
Stories
1
Heated Area (Sqft)
3579.00
Total Area (Sqft)
5884.00
Building Code Edition
Florida Building Code 2017 6th Edition & 2014 National Electrical Code
Septic# (00-0000) or (X00-000)
18-0914

Status & Review History

No status updates yet.

Contractors

  • Bryan Zecher

    License
    CBC1257343
    Title
    —
    Role
    —

Inspections

  1. Jan 9, 2019

    Passed: Building - Footer

    Inspected by Troy Crews

  2. Jan 9, 2019

    Passed: Engineering - Setbacks

    Inspected by Troy Crews

  3. Jan 16, 2019

    Release to power company

    Inspected by Troy Crews

  4. Jan 17, 2019

    Passed: Electrical - Temporary Service

    Inspected by Troy Crews

  5. Feb 8, 2019

    Passed: Plumbing/Gas - Rough In

    Inspected by Troy Crews

  6. Feb 14, 2019

    Passed: Building - Slab

    Inspected by Troy Crews

  7. Mar 18, 2019

    Passed: Building - Ext Strapping/Wall Sheathing

    Inspected by Troy Crews

  8. Apr 4, 2019

    Passed: Building - Roof Decking

    Inspected by Troy Crews

  9. Apr 12, 2019

    Failed: Building - Framing

    Check All Threads Some Loose check Clips For Truss A03, A04, G01, A07

    Inspected by Tommy Matthews

  10. May 2, 2019

    Passed: Building - Framing

    Items Corrected

    Inspected by Troy Crews

  11. May 2, 2019

    Passed: Electrical - Rough In

    Inspected by Troy Crews

  12. May 2, 2019

    Passed: Mechanical - Rough In

    Inspected by Troy Crews

  13. May 2, 2019

    Passed: Plumbing/Gas - Rough In

    Inspected by Troy Crews

  14. May 14, 2019

    Passed: Building - Insulation

    Inspected by Troy Crews

  15. Aug 20, 2019

    Passed: Electrical - Permanent Power

    Need Health And Driveway Finals

    Inspected by Troy Crews

  16. Sep 11, 2019

    Release to power company

    Eh & Dw Finals Rec'd.

    Inspected by Tc

  17. Sep 11, 2019

    Septic Release Inspection

    Inspected by Health Dept

  18. Dec 3, 2019

    Passed: Building - Final

    Need Blower Door Test-- Rec'd

    Inspected by Troy Crews