Permit Details

Permit Search

Permit

New Residential Construction

766 SW MARION MANN TERRACE
LAKE CITY, FL 32024

Permit #
000036991
Application #
39119
Status Completed
  1. Submitted Jul 19, 2018
  2. Issued Jul 19, 2018
  3. Expires Oct 28, 2019
  4. Completed May 10, 2019

Property

Parcel #
09622-002
Owner
Damon Stone
Acres
50.00
Subdivision
—
Zoning
A-3
Flood zone
X
District
4

Permit

Status
Completed
Septic release
Released
Related permit
—

Job Details

Finished floor requirement
Fema map number
12023C0485C
This is the construction of a
SFD/UTILITY
Setbacks Front
30.00
Setback Side 1
25.00
Setback Side 2
25.00
Setbacks Rear
25.00
Stories
1
Heated Area (Sqft)
4260.00
Total Area (Sqft)
9820.00
Building Code Edition
Florida Building Code 2017 6th Edition & 2014 National Electrical Code
Septic# (00-0000) or (X00-000)
18-0648

Status & Review History

No status updates yet.

Contractors

  • Matthew Hentzelman

    License
    CGC1514780
    Title
    —
    Role
    —

    County License & State License Expired.

Inspections

  1. Aug 9, 2018

    Passed: Building - Footer

    Does Not Include Interior Pads

    Inspected by Troy Crews

  2. Aug 9, 2018

    Passed: Engineering - Setbacks

    Inspected by Troy Crews

  3. Aug 29, 2018

    Passed: Electrical - Underground Rough-In

    Inspected by Troy Crews

  4. Aug 29, 2018

    Passed: Plumbing/Gas - Underground Rough-In

    Inspected by Troy Crews

  5. Sep 11, 2018

    Passed: Building - Slab

    Inspected by Troy Crews

  6. Sep 26, 2018

    Passed: Building - Lintel/Tie Beam

    Inspected by Troy Crews

  7. Sep 26, 2018

    Passed: Building - Masonry Wall Reinforcing

    Inspected by Troy Crews

  8. Sep 27, 2018

    Passed: Building - Footer

    Inspected by Troy Crews

  9. Sep 27, 2018

    Passed: Engineering - Setbacks

    Inspected by Troy Crews

  10. Oct 4, 2018

    Passed: Plumbing/Gas - Underground Rough-In

    North End Suite

    Inspected by Troy Crews

  11. Oct 12, 2018

    Passed: Building - Slab

    Inspected by Troy Crews

  12. Oct 22, 2018

    Failed: Building - Roof Decking

    Drive Down High Nails Remove Shiners (multiple Areas)

    Inspected by Troy Crews

  13. Oct 23, 2018

    Passed: Building - Roof Decking

    Inspected by Troy Crews

  14. Oct 31, 2018

    Passed: Building - Roof Decking

    Roof And Walls North Suite

    Inspected by Troy Crews

  15. Nov 1, 2018

    Passed: Building - Ext Strapping/Wall Sheathing

    Done 10:31

    Inspected by Troy Crews

  16. Dec 13, 2018

    Failed: Building - Framing

    Need Drawing For Attic Storage Roof Build Over, Ridge And Rafter Attachments

    Inspected by Troy Crews

  17. Dec 20, 2018

    Passed: Building - Framing

    Main House

    Inspected by Troy Crews

  18. Dec 20, 2018

    Passed: Electrical - Rough In

    Main House

    Inspected by Troy Crews

  19. Dec 20, 2018

    Passed: Mechanical - Rough In

    Main House

    Inspected by Troy Crews

  20. Dec 20, 2018

    Passed: Plumbing/Gas - Rough In

    Main House

    Inspected by Troy Crews

  21. Dec 26, 2018

    Failed: Building - Framing

    All Threads Not Complete. See Circles Of Missing On Plans

    Inspected by Tommy Matthews

  22. Dec 26, 2018

    Failed: Electrical - Rough In

    Conduit Above Panel Limited To 2’ Unless Calculations Are Provided.

    Inspected by Tommy Matthews

  23. Dec 26, 2018

    Failed: Mechanical - Rough In

    Not Complete

    Inspected by Tommy Matthews

  24. Dec 26, 2018

    Passed: Plumbing/Gas - Rough In

    Inspected by Tommy Matthews

  25. Dec 27, 2018

    Cancelled: Building - Framing

    Inspected by Randy Jones

  26. Dec 27, 2018

    Cancelled: Electrical - Rough In

    Inspected by Randy Jones

  27. Dec 27, 2018

    Cancelled: Mechanical - Rough In

    Inspected by Randy Jones

  28. Dec 27, 2018

    Cancelled: Plumbing/Gas - Rough In

    Inspected by Randy Jones

  29. Dec 27, 2018

    Passed: Building - Insulation

    Inspected by Randy Jones

  30. Jan 3, 2019

    Passed: Building - Framing

    Inspected by Troy Crews

  31. Jan 3, 2019

    Passed: Electrical - Rough In

    Split Pipe To Less Than Two Feet

    Inspected by Troy Crews

  32. Jan 3, 2019

    Passed: Mechanical - Rough In

    Completed

    Inspected by Troy Crews

  33. Jan 7, 2019

    Passed: Building - Insulation

    Inspected by Troy Crews

  34. Jan 28, 2019

    Passed: Building - Lath/Stucco

    Inspected by Troy Crews

  35. Mar 22, 2019

    Passed: Electrical - Permanent Power

    Existing Drive Need Health Release

    Inspected by Troy Crews

  36. Mar 25, 2019

    Release to power company

    Inspected by Laurie Hodson

  37. Mar 25, 2019

    Septic Release Inspection

    Inspected by Health Dept

  38. Apr 10, 2019

    Rescheduled 4/12/2019:Building - Final

    Inspected by Janice Williams

  39. Apr 12, 2019

    Failed: Building - Final

    Main House Not Complete North Suite Ok For Occupancy Temporarily Until Full C.o.

    Inspected by Troy Crews

  40. May 1, 2019

    Passed: Building - Final

    Co Release Pending Soffit Completion

    Inspected by Troy Crews

Documents