Permit Details

Permit Search

Permit

New Residential Construction

137 SW ASHEVILLE WAY LAKE CITY FL 32024

Permit #
000036626
Application #
37574
Status Completed
  1. Submitted Apr 25, 2018
  2. Issued Apr 25, 2018
  3. Expires Sep 10, 2019
  4. Completed Mar 14, 2019

Property

Parcel #
03124-102
Owner
Matthew & Carrie Cason
Acres
0.32
Subdivision
Hickory Cove
Zoning
PRD
Flood zone
X
District
5

Permit

Status
Completed
Septic release
Released
Related permit
—

Job Details

Finished floor requirement
Fema map number
12023C0381D
This is the construction of a
SFD/UTILITY
Setbacks Front
25.00
Setback Side 1
10.00
Setback Side 2
10.00
Setbacks Rear
15.00
Stories
1
Heated Area (Sqft)
1826.00
Total Area (Sqft)
2592.00
Building Code Edition
Florida Building Code 2017 6th Edition & 2014 National Electrical Code
Septic# (00-0000) or (X00-000)
18-0187

Status & Review History

No status updates yet.

Contractors

  • W. Stanley Crawford

    License
    RG0042896
    Title
    —
    Role
    —

    County License & State License & Liability Insurance & Workers Comp & Employees Workers Comp Expired.

Inspections

  1. May 8, 2018

    Passed: Building - Footer

    Inspected by Tommy Matthews

  2. May 8, 2018

    Passed: Engineering - Setbacks

    Inspected by Tommy Matthews

  3. May 22, 2018

    Failed: Plumbing/Gas - Underground Rough-In

    No Plumbing Installed

    Inspected by Tommy Matthews

  4. May 24, 2018

    Passed: Electrical - Temporary Service

    Inspected by Troy Crews

  5. May 24, 2018

    Release to power company

    Inspected by Troy Crews

  6. May 25, 2018

    Passed: Plumbing/Gas - Underground Rough-In

    Inspected by Troy Crews

  7. May 30, 2018

    Passed: Building - Slab

    Inspected by Troy Crews

  8. Sep 10, 2018

    Passed: Building - Ext Strapping/Wall Sheathing

    Inspected by Tommy Matthews

  9. Sep 25, 2018

    Failed: Mechanical - Rough In

    Dryer Vent Not Correctly Installed

    Inspected by Tommy Matthews

  10. Sep 25, 2018

    Failed: Electrical - Rough In

    Need Electric To Island Cabinets

    Inspected by Tommy Matthews

  11. Sep 25, 2018

    Passed: Plumbing/Gas - Tub Set/Shower Pan

    Inspected by Tommy Matthews

  12. Sep 25, 2018

    Failed: Building - Framing

    Need Additional Strap On Each Side Of Garage Door. need New Sealed Truss Drawings Prior To Inspection.

    Inspected by Tommy Matthews

  13. Sep 27, 2018

    Failed: Building - Framing

    No Sealed Truss Drawings That Match Trusses On Hs.

    Inspected by Troy Crews

  14. Sep 27, 2018

    Passed: Electrical - Rough In

    Island Power Installed

    Inspected by Troy Crews

  15. Sep 27, 2018

    Failed: Mechanical - Rough In

    Duct Work Not Complete

    Inspected by Troy Crews

  16. Sep 27, 2018

    Passed: Plumbing/Gas - Tub Set/Shower Pan

    Passed On 9-25-18

    Inspected by Troy Crews

  17. Oct 2, 2018

    Passed: Building - Insulation

    Inspected by Troy Crews

  18. Oct 2, 2018

    Passed: Building - Framing

    Inspected by Troy Crews

  19. Oct 2, 2018

    Failed: Mechanical - Rough In

    Need To Connect Return In Nw Bedroom

    Inspected by Troy Crews

  20. Dec 17, 2018

    Septic Release Inspection

    Inspected by Health Dept

  21. Dec 18, 2018

    Failed: Electrical - Permanent Power

    Need Garage Door To Secure Garage Where Panel Box Is Located Prior To Turning On Power.

    Inspected by Tommy Matthews

  22. Jan 4, 2019

    Passed: Electrical - Permanent Power

    Inspected by Tommy Matthews

  23. Jan 4, 2019

    Release to power company

    Inspected by Tommy Matthews

  24. Mar 12, 2019

    Failed: Building - Final

    Need Blower Door Test. need Safety Bumper In Garage

    Inspected by Tommy Matthews

  25. Mar 14, 2019

    Passed: Building - Final

    Inspected by Tommy Matthews