Permit Details

Permit Search

Permit

New Commercial Construction

13700 S US HIGHWAY 441 LAKE CITY FL 32025

Permit #
000035832
Application #
35844
Status Completed
  1. Submitted Oct 2, 2017
  2. Issued Oct 2, 2017
  3. Expires Dec 25, 2018
  4. Completed Jun 28, 2018

Property

Parcel #
09563-001
Owner
Love's Travel Stops & Country Stores Inc
Acres
17.83
Subdivision
—
Zoning
CHI
Flood zone
X
District
4

Permit

Status
Completed
Septic release
Not yet released
Related permit
—

Job Details

Finished floor requirement
Fema map number
12023C0415C
This is the construction of a:
LOVE'S TRAVEL STORE
Setbacks Front
20.00
Setback Side 1
5.00
Setback Side 2
5.00
Setback Rear
15.00
Stories
1
Heated Area (Sqft)
11460.00
Total Area (Sqft)
33001.00
Building Code Edition
Florida Building Code 2017 6th Edition & 2014 National Electrical Code
Septic# (00-0000) or (X00-000)
COUNTY

Status & Review History

No status updates yet.

Contractors

  • Carl Herndon

    License
    CBC047843
    Title
    —
    Role
    —

    County License & State License & Liability Insurance & Workers Comp Expired.

Inspections

  1. Oct 12, 2017

    Foundation Inspection

    Inspected by Troy Crews

  2. Oct 12, 2017

    Setback Inspection

    Inspected by Troy Crews

  3. Oct 13, 2017

    Temporary Power Inspection

    Inspected by Troy Crews

  4. Oct 25, 2017

    Passed: Foundation

    Inspected by Troy Crews

  5. Nov 1, 2017

    Slab Inspection

    Inspected by Troy Crews

  6. Dec 6, 2017

    Passed: Building - Footer

    Tire Shop Partial

    Inspected by Troy Crews

  7. Dec 6, 2017

    Cancelled: Building - Footer

    Inspected by Troy Crews

  8. Dec 12, 2017

    Rough-In Plumbing Inspection

    Inspected by Troy Crews

  9. Dec 12, 2017

    Passed: Plumbing/Gas - Underground Rough-In

    Waste Lines Tire Shop

    Inspected by Troy Crews

  10. Dec 13, 2017

    Monolithic Slab Inspection

    Inspected by Troy Crews

  11. Dec 13, 2017

    Passed: Building - Footer

    Partial Tire Shop

    Inspected by Troy Crews

  12. Dec 13, 2017

    Passed: Building - Slab

    Partial Slab Tire Store.

    Inspected by Troy Crews

  13. Dec 13, 2017

    Passed: Fire - Underground Main - Visual

    Done By F.d 12-13-17 Partial

    Inspected by J.w.

  14. Dec 14, 2017

    Passed: Building - Ext Strapping/Wall Sheathing

    Main Building Walls

    Inspected by Troy Crews

  15. Dec 18, 2017

    Underslab Rough Plumbing Inspection

    Inspected by Troy Crews

  16. Dec 18, 2017

    Passed: Plumbing/Gas - Underground Rough-In

    Inspected by Troy Crews

  17. Dec 20, 2017

    Passed: Fire - Underground Main - Visual

    Inspected by Josh Wehinger

  18. Dec 20, 2017

    Passed: Building - Slab

    Inspected by Troy Crews

  19. Dec 20, 2017

    Passed: Plumbing/Gas - Interceptor

    Grease Trap

    Inspected by Troy Crews

  20. Dec 28, 2017

    Framing Inspection

    Inspected by Troy Crews

  21. Dec 28, 2017

    Electrical Rough-In Inspection

    Inspected by Troy Crews

  22. Dec 28, 2017

    Passed: Building - Framing

    North End Bathroom Area

    Inspected by Troy Crews

  23. Dec 28, 2017

    Passed: Electrical - Rough In

    North End Bathroom Area

    Inspected by Troy Crews

  24. Dec 28, 2017

    Passed: Plumbing/Gas - Water Pipe

    North End Bathroom Area

    Inspected by Troy Crews

  25. Jan 2, 2018

    Passed: Fire - Underground Main - Visual

    Inspected by Josh Wehinger

  26. Jan 3, 2018

    Passed: Fire - Underground Main - Visual

    Done By Josh 1-2-18

    Inspected by Troy Crews

  27. Jan 8, 2018

    Passed: Building - Insulation

    Exterior Walls North End

    Inspected by Troy Crews

  28. Jan 8, 2018

    Passed: Building - Insulation

    North End Exterior Walls

    Inspected by Troy Crews

  29. Jan 11, 2018

    Passed: Fire - Underground Main - Visual

    Inspected by Josh Wehinger

  30. Jan 24, 2018

    Passed: Building - Insulation

    South End Of Building

    Inspected by Troy Crews

  31. Jan 24, 2018

    Passed: Electrical - Rough In

    South End Of Building

    Inspected by Troy Crews

  32. Jan 24, 2018

    Passed: Plumbing/Gas - Rough In

    South End Of Building

    Inspected by Troy Crews

  33. Feb 5, 2018

    Passed: Building - Slab

    Truck Pump Area

    Inspected by Troy Crews

  34. Feb 20, 2018

    Passed: Building - Framing

    Framing And Wall Sheathing Need To Look At Roof Screws,

    Inspected by Troy Crews

  35. Mar 5, 2018

    Passed: Building - Insulation

    Inspected by Troy Crews

  36. Mar 5, 2018

    Passed: Building - Rated Assembly Fastening

    Inspected by Troy Crews

  37. Mar 6, 2018

    Passed: Building - Insulation

    Inspected by Troy Crews

  38. Mar 6, 2018

    Passed: Electrical - Rough In

    Inspected by Troy Crews

  39. Mar 6, 2018

    Passed: Plumbing/Gas - Rough In

    Inspected by Troy Crews

  40. Mar 8, 2018

    Rescheduled 3/9/2018:Building - Footer

    Will @ 601-470-8201

    Inspected by Laurie Hodson

  41. Mar 8, 2018

    Rescheduled 3/9/2018:Engineering - Setbacks

    Inspected by Laurie Hodson

  42. Mar 8, 2018

    Passed: Building - Insulation

    Inspected by Troy Crews

  43. Mar 9, 2018

    Cancelled: Building - Footer

    Canceled By Will 601-470-8201

    Inspected by Laurie Hodson

  44. Mar 13, 2018

    Rescheduled 3/14/2018:Building - Footer

    Will Changed Date (around Noon)

    Inspected by Laurie Hodson

  45. Mar 13, 2018

    Rescheduled 3/14/2018:Engineering - Setbacks

    Will Changed Date (around Noon)

    Inspected by Laurie Hodson

  46. Mar 14, 2018

    Cancelled: Building - Footer

    Inspected by Troy Crews

  47. Mar 15, 2018

    Passed: Mechanical - Kitchen Hood

    Grease Hoods

    Inspected by Troy Crews

  48. Mar 15, 2018

    Passed: Mechanical - Light Test

    Showed No Leaks

    Inspected by Troy Crews

  49. Mar 16, 2018

    Passed: Mechanical - Rough In

    Ceiling Rough In

    Inspected by Troy Crews

  50. Mar 19, 2018

    Rescheduled 3/20/2018:Building - Footer

    Inspected by Troy Crews

  51. Mar 19, 2018

    Rescheduled 3/20/2018:Engineering - Setbacks

    Inspected by Troy Crews

  52. Mar 20, 2018

    Passed: Building - Footer

    Mono Pole Sign

    Inspected by Troy Crews

  53. Mar 20, 2018

    Passed: Engineering - Setbacks

    Mono Pole Sign

    Inspected by Troy Crews

  54. Mar 27, 2018

    Passed: Building - Footer

    Inspected by Troy Crews

  55. Mar 27, 2018

    Passed: Engineering - Setbacks

    Inspected by Troy Crews

  56. Apr 13, 2018

    Passed: Building - Footer

    Inspected by Troy Crews

  57. Apr 13, 2018

    Passed: Engineering - Setbacks

    Inspected by Troy Crews

  58. Apr 16, 2018

    Passed: Electrical - Permanent Power

    Awaiting Release From Public Works On Water And Sewer

    Inspected by Troy Crews

  59. Apr 20, 2018

    Release to power company

    Letter From County Water System Rec'd

    Inspected by Laurie Hodson

  60. Apr 30, 2018

    Passed: Building - Above Ceiling

    Inspected by Troy Crews

  61. May 18, 2018

    Passed: Fire - Operational Test - Chemical/Gaseous Agent

    Inspected by Josh Wehinger

  62. May 21, 2018

    Passed: Building - Final

    Pending D.o.t. Final And Public Works Release

    Inspected by Troy Crews

  63. May 21, 2018

    Passed: Mechanical - Refrigeration

    Inspected by Troy Crews

  64. May 21, 2018

    Rescheduled 5/23/2018:Engineering - Zoning Final

    Inspected by Troy Crews

  65. May 22, 2018

    Passed: Fire - Fire Final

    Inspected by Josh Wehinger

  66. May 23, 2018

    Failed: Engineering - Zoning Final

    Site Was Not Complete. Landscaping Inspection Complete

    Inspected by Brandon Stubbs

  67. May 25, 2018

    Plumbing/Gas-Water Pipe

    Water & Sewer Services At County Connection Points

    Inspected by Robert Dominque

  68. Jun 4, 2018

    Passed: Engineering - Final Driveway

    Fdot Final Approval Rec'd

    Inspected by Troy Register, Dot

  69. Jun 5, 2018

    Passed: Engineering - Zoning Final

    All Complete

    Inspected by Brandon Stubbs

  70. Jun 6, 2018

    CERTIFICATE OF OCCUPANCY/COMPLETION DATE

    Temporary Co For Store Use

  71. Jun 6, 2018

    Passed: Fire - Operational Test - Fire Pump

    Tire Store

    Inspected by Josh Wehinger

  72. Jun 15, 2018

    Release to power company

    Inspected by Troy Crews

  73. Jun 18, 2018

    Passed: Electrical - Permanent Power

    100 Amp Three Phase For Fire Pump

    Inspected by Troy Crews

  74. Jun 28, 2018

    Building-Final

    All Completed

    Inspected by Troy Crews

  75. Jun 28, 2018

    Final Inspection

    Inspected by Troy Crews

  76. Jun 28, 2018

    CERTIFICATE OF OCCUPANCY/COMPLETION DATE

  77. Jun 28, 2018

    Passed: Fire - Fire Final

    Inspected by Josh Wehinger

  78. Jun 28, 2018

    Passed: Fire - Operational Test - Fire Pump

    Inspected by Troy Crews

  79. Jun 28, 2018

    Passed: Fire - Fire Final

    Inspected by Troy Crews

Documents