Permit Details

Permit Search

Permit

Roof Replacement or Repair

258 SW MARKS DR
LAKE CITY, FL 32024

Permit #
000056678
Application #
80033
Status Completed
  1. Submitted Sep 28, 2026
  2. Issued Sep 28, 2026
  3. Expires Apr 11, 2027
  4. Completed Oct 13, 2026

Property

Parcel #
02755-000
Owner
Scarpa Stephen, Scarpa Theresa R
Acres
1.39
Subdivision
Westwood Acres
Zoning
RSF-2
Flood zone
X
District
3

Permit

Status
Completed
Septic release
N/A
Related permit
—

Job Details

Finished floor requirement
Fema map number
12023C0290D
Type Roofing Job
Replacement - Tear off Existing and Replace
Further Job Details (Explain if decking is being replaced and or Repairs are being done.)
Re-roofing | No Structural Modification. The existing 1–2 layers of asphalt shingles will be torn off and disposed of. Damaged decking will be repaired or replaced using OSB/plywood where applicable, followed by the installation of premium synthetic underlayment, ice and water shield, new drip edge, and IKO fiberglass dimensional shingles.
Type of structure
House
Commercial or Residential
Residential
Roof Area (for this job) Sq Ft
3079
No. of Stories
1
Roof Pitch
2:12 to 4:12
Is the existing roof being removed?
Yes
Type of New Roofing Product
Asphalt Shingles
Florida Product Approval Number
FL30310.1
Other Roofing Product Type Not Listed
2 Layers Synthetic Veer Ultra (FL20767.1)  (FG) Standard Ridge (FL6267.1)
Product Manufacturer
IKO
Product Description
IKO DYNASTY FG
Building Code Edition
2023 Florida Building Code 8th Edition and 2020 National Electrical Code
Sealed roof decking options: (Must select an option.)
two layers of felt underlayment comply ASTM 0226 Type II or ASTM D4869 Type Ill or IV, or two layers of a synthetic underlayment meeting the performance requirements specified, lapped and fastened as specified.
Ventilation:
Ridge Vent
Flashing:
Replace with Step Flashing
Drip Edge:
Replace All
Valley Treatment:
Use Existing
Second Roof Pitch (if applicable)
Less than 2:12
Any cable and/or race-way wiring located on or within the roof assembly?
No

Status & Review History

  1. Application pending.
  2. Application is within the City of Lake City service area
  3. Application Status Update Notification
  4. Submitted by building department on applicant's behalf
  5. City of Lake City Utilities Notified.
  6. Permit Issued

Contractors

  • Robert Rozanski

    Erie Construction Mid-west Llc

    License
    CCC1336152
    Title
    Cert. Roofing
    Role
    Contractor

Inspections

  1. Oct 5, 2026

    Passed: Re-Roof - Roof Affidavit Review

    Inspected by Matt Forsyth

  2. Oct 6, 2026

    Rescheduled 10/8/2026:Re-Roof - In Progress

    Rescheduled Due To Rain

    Inspected by Nanderson

  3. Oct 8, 2026

    Passed: Re-Roof - In Progress

    Inspected by Christian Allen

  4. Oct 12, 2026

    Passed: Re-Roof - Roof Pictures Review

    Inspected by Christian Allen

  5. Oct 13, 2026

    Passed: Re-Roof - In Progress

    Inspected by Matt Forsyth

  6. Oct 13, 2026

    Passed: Re-Roof - Final

    Inspected by Matt Forsyth