Permit Details

Permit Search

Permit

Roof Replacement or Repair

3686 SW CENTERVILLE AVE
FORT WHITE, FL 32038

Permit #
000056452
Application #
78533
Status Completed
  1. Submitted Aug 17, 2026
  2. Issued Aug 31, 2026
  3. Expires Feb 27, 2027
  4. Completed Sep 2, 2026

Property

Parcel #
03969-007
Owner
Shirk Family Revocable Trust,
Acres
9.65
Subdivision
—
Zoning
A-3
Flood zone
X
District
2

Permit

Status
Completed
Septic release
N/A
Related permit
—

Job Details

Finished floor requirement
Fema map number
12023C0490C
Type Roofing Job
Replacement - Tear off Existing and Replace
Further Job Details (Explain if decking is being replaced and or Repairs are being done.)
Tear off existing metal and replace with new metal
Type of structure
Mobile Home
Commercial or Residential
Residential
Roof Area (for this job) Sq Ft
26
No. of Stories
1
Roof Pitch
2:12 to 4:12
Is the existing roof being removed?
Yes
Type of New Roofing Product
Metal
Florida Product Approval Number
FL36904-R12
Product Manufacturer
Tri County Metals
Product Description
PBR
Building Code Edition
2023 Florida Building Code 8th Edition and 2020 National Electrical Code
Sealed roof decking options: (Must select an option.)
two layers of felt underlayment comply ASTM 0226 Type II or ASTM D4869 Type Ill or IV, or two layers of a synthetic underlayment meeting the performance requirements specified, lapped and fastened as specified.
Ventilation:
Ridge Vent
Flashing:
Use Existing
Drip Edge:
Use Existing
Valley Treatment:
Use Existing
Any cable and/or race-way wiring located on or within the roof assembly?
No

Status & Review History

  1. Application pending.
  2. Application submitted by applicant.
  3. Application Status Update Notification
  4. Other was not accepted.
  5. Application Status Update Notification
  6. Permit Issued

Contractors

  • Joshua Lewis

    Retex Roofing Fl Llc

    License
    CCC1333219
    Title
    Cert. Roofing
    Role
    Contractor
  • Timothy Hunt

    Ct Solutions Of Florida Llc

    License
    BN7162
    Title
    Private Inspector
    Role
    Private Inspector

Inspections

  1. Aug 31, 2026

    Passed: Private Provider - Private Provider Inspection

    In Progress And Final Received On 8/31/26

    Inspected by Private Provider Inspector