Permit Details

Permit Search

Permit

Roof Replacement or Repair

316 SE CATALDO GLN
HIGH SPRINGS, FL 32643

Permit #
000056442
Application #
78701
Status Completed
  1. Submitted Aug 28, 2026
  2. Issued Aug 31, 2026
  3. Expires Mar 16, 2027
  4. Completed Sep 17, 2026

Property

Parcel #
09984-010
Owner
Cocilovo Patricia A
Acres
4.06
Subdivision
Oleno Estates
Zoning
A-3
Flood zone
X
District
4

Permit

Status
Completed
Septic release
N/A
Related permit
—

Job Details

Finished floor requirement
Fema map number
12023C0514C
Type Roofing Job
Replacement - Tear off Existing and Replace
Further Job Details (Explain if decking is being replaced and or Repairs are being done.)
Tear off 1–2 layers of existing asphalt shingles from the one-story home. Replace damaged wood decking with OSB/CDX plywood sheathing where applicable, and install two layers of synthetic underlayment featuring Veer Ultra, ice and water shield, and new IKO Dynasty fiberglass shingles finished with a standard ridge. Vent the roof properly and install all accessories, including a drip edge, pipe boots, and flashing. Note that work will not be performed on RF1, RF5, the metal roof on the front porch, or any other sheds or buildings. No structural changes
Type of structure
Mobile Home
Commercial or Residential
Residential
Roof Area (for this job) Sq Ft
1782
No. of Stories
1
Roof Pitch
2:12 to 4:12
Is the existing roof being removed?
Yes
Type of New Roofing Product
Asphalt Shingles
Florida Product Approval Number
FL 30310.1
Product Manufacturer
IKO Industries Ltd
Product Description
IKO Dynasty Fiberglass Shingles
Building Code Edition
2023 Florida Building Code 8th Edition and 2020 National Electrical Code
Sealed roof decking options: (Must select an option.)
two layers of felt underlayment comply ASTM 0226 Type II or ASTM D4869 Type Ill or IV, or two layers of a synthetic underlayment meeting the performance requirements specified, lapped and fastened as specified.
Ventilation:
Ridge Vent
Flashing:
Use Existing
Drip Edge:
Replace All
Valley Treatment:
New Mineral Surface
Second Roof Pitch (if applicable)
4:12 or Greater
Any cable and/or race-way wiring located on or within the roof assembly?
No

Status & Review History

  1. Application pending.
  2. Submitted by building department on applicant's behalf
  3. Permit Issued

Contractors

  • Robert Rozanski

    Erie Construction Mid-west Llc

    License
    CCC1336152
    Title
    Cert. Roofing
    Role
    Contractor

Inspections

  1. Sep 15, 2026

    Passed: Re-Roof - In Progress

    Texted Pictures

    Inspected by Troy Crews

  2. Sep 16, 2026

    Passed: Re-Roof - Roof Pictures Review

    Inspected by Christian Allen

  3. Sep 16, 2026

    Passed: Re-Roof - Roof Affidavit Review

    Inspected by Christian Allen

  4. Sep 17, 2026

    Passed: Re-Roof - Final

    Inspected by Christian Allen