Permit Details

Permit Search

Permit

Roof Replacement or Repair

362 SW WASHINGTON AVE
FORT WHITE, FL 32038

Permit #
000056424
Application #
76784
Status Completed
  1. Submitted Jun 18, 2026
  2. Issued Aug 26, 2026
  3. Expires Apr 19, 2027
  4. Completed Oct 21, 2026

Property

Parcel #
00862-000
Owner
Ramlow Bradley Vincent, Hammis Zoe Josephine
Acres
0.87
Subdivision
Three Rivers Estates Unit 11
Zoning
A-3
Flood zone
X
District
2

Permit

Status
Completed
Septic release
N/A
Related permit
—

Job Details

Finished floor requirement
Fema map number
12023C0458C
Type Roofing Job
Replacement - Tear off Existing and Replace
Type of structure
House
Commercial or Residential
Residential
Roof Area (for this job) Sq Ft
1900
No. of Stories
1
Roof Pitch
2:12 to 4:12
Is the existing roof being removed?
Yes
Type of New Roofing Product
Metal
Florida Product Approval Number
FL36904-R12
Product Manufacturer
Tri County Metals
Product Description
ULTRA RIB PANEL (SMP) Gauge: 26 Color: Dark Gray
Building Code Edition
2023 Florida Building Code 8th Edition and 2020 National Electrical Code
Sealed roof decking options: (Must select an option.)
a minimum 4-inch wide strip of selfadhering polymer-modified bitumen complying with ASTM D1970 or a minimum 3 ¾ - inch wide strip of selfadhering flexible flashing tape complying with AAMA 711, applied over all joints in the roof decking. A felt underlayment complying with ASTM D226 Type II, ASTM D4869 Type Ill or IV, or ASTM D6757, or a synthetic underlayment meeting the performance requirements specified, is required to be applied over the strips/tape over the entire roof.
Ventilation:
Off-ridge Vent
Flashing:
Repair Existing
Drip Edge:
Replace All
Valley Treatment:
New Metal
Any cable and/or race-way wiring located on or within the roof assembly?
Yes

Status & Review History

  1. Application pending.
  2. Application submitted by applicant.
  3. Application Status Update Notification
  4. Application Status Update Notification
  5. Application Status Update Notification
  6. Application Status Update Notification
  7. Application Status Update Notification
  8. Application Status Update Notification
  9. Application Status Update Notification
  10. Application Status Update Notification
  11. Application Status Update Notification
  12. Application Status Update Notification
  13. Application Status Update Notification
  14. Permit Issued

Contractors

No contractors are listed on this permit.

Inspections

  1. Oct 20, 2026

    Passed: Re-Roof - In Progress

    Inspected by Matt Forsyth

  2. Oct 21, 2026

    Passed: Re-Roof - Final

    Owner Builder Attic Ventilation Confirmed

    Inspected by Matt Forsyth