Permit Details

Permit Search

Permit

New Residential Construction

1431 SE MYRTIS RD
LAKE CITY, FL 32025

Permit #
000056187
Application #
76597
Status Permit Issued
  1. Submitted Jul 23, 2026
  2. Issued Jul 28, 2026
  3. Expires Jul 28, 2027
  4. Completed —

Property

Parcel #
09213-002
Owner
Goodenbury Aron, Goodenbury Jennifer
Acres
4.45
Subdivision
—
Zoning
A-3
Flood zone
X
District
4

Permit

Status
Permit Issued
Septic release
Not yet released
Related permit
—

Job Details

Elevation regulation
Minimum Requirement
Finished floor requirement
FFE OF THE HOME SHALL BE 12” ABOVE THE ADJACENT GROUND AT FOUNDATION
Requirement needed
Slab Inspection
Document needed is
Upload Photos
Document receieved
No
Fema map number
12023C0405C
This is the construction of a
Accessory Dwelling
Setbacks Front
30'
Setback Side 1
25'
Setback Side 2
25'
Setbacks Rear
25'
Stories
1
Heated Area (Sqft)
800
Total Area (Sqft)
1200
Building Height
16
Building Code Construction Type
V
Building Code Element
B
Building Code Occupancy Types
Residential
Occupancy Use Title
SINGLE FAMILY DWELLING
Building Code Edition
2023 Florida Building Code 8th Edition and 2020 National Electrical Code
Septic# (00-0000) or (X00-000)
26-0537
Sealed roof decking options. (Must select one option per FBC 2023 8th Edition)
two layers of felt underlayment comply ASTM 0226 Type II or ASTM D4869 Type Ill or IV, or two layers of a synthetic underlayment meeting the performance requirements specified, lapped and fastened as specified.
Service Amps
200

Status & Review History

  1. Application pending.
  2. Application Information Page was not accepted.
  3. Application Status Update Notification
  4. Application Status Update Notification
  5. Application Status Update Notification
  6. Application Status Update Notification
  7. Application Status Update Notification
  8. Application Status Update Notification
  9. Application submitted by applicant.
  10. Application submitted by applicant.
  11. Application Status Update Notification
  12. Permit Issued

Contractors

  • Sara E Gresham

    John Norris Construction, Llc

    License
    CRC1331978
    Title
    Cert. Residential
    Role
    Contractor
  • Donald R Hollingsworth

    Holly Electric Inc

    License
    EC13005429
    Title
    Electrical
    Role
    Subcontractor
  • Jan R Touchton

    Touchton's Heating & Air Conditioning Inc

    License
    CAC058747
    Title
    Cert. A/c Class “a”
    Role
    Subcontractor
  • Don C Bills Sr

    Hometown Plumbing Services Llc

    License
    CFC1428890
    Title
    Plumbing Contractor
    Role
    Subcontractor
  • Mary C Johnson

    Rcra Johnson Roofing,inc.

    License
    CCC1330073
    Title
    Roofing Contractor
    Role
    Subcontractor
  1. Aug 7, 2026

    Passed: Plumbing/Gas - 1st Underground Rough–In

    Dwv Under Slab Only, No Water, Pool House, Enter Off Co 245 1st Gate North Of Myrtis Rd

    Inspected by Gary Pitzer

  2. Aug 11, 2026

    Passed: Building - Footer

    Inspected by Troy Crews

  3. Aug 11, 2026

    Cancelled: Electrical - Footer Steel & Grounding

    Not Needed

    Inspected by Tcrews

  4. Aug 11, 2026

    Passed: Engineering - Setbacks

    Inspected by Troy Crews

  5. Aug 11, 2026

    Cancelled: Electrical - Footer Steel & Grounding

    Inspected by Tcrews

  6. Aug 11, 2026

    Cancelled: Engineering - Setbacks

    Inspected by Tcrews

  7. Sep 9, 2026

    Passed: Building - Wall Sheathing

    Inspected by Gary Pitzer

  8. Sep 9, 2026

    Failed: Building - Roof Decking

    Nothing Installed Reschedule When Completed

    Inspected by Gary Pitzer

  9. Sep 15, 2026

    Passed: Building - Roof Decking

    Inspected by Troy Crews

  10. Oct 1, 2026

    Cancelled: Building - Ext Strapping/Wall Sheathing

    Inspected by Tcrews

  11. Oct 1, 2026

    Passed: Building - Framing

    Inspected by Troy Crews

  12. Oct 1, 2026

    Passed: Electrical - 2nd Rough-In

    Inspected by Troy Crews

  13. Oct 1, 2026

    Passed: Plumbing/Gas - 2nd Rough-In

    Inspected by Troy Crews

  14. Oct 1, 2026

    Passed: Building - Strapping

    Inspected by Troy Crews

  15. Oct 21, 2026

    Cancelled: Building - Insulation

    Inspected by Tcrews

  16. Oct 21, 2026

    Cancelled: Building - Insulation

    Inspected by Tcrews

  17. Oct 22, 2026

    Passed: Building - Insulation

    Foam Roof And R13 Batts In Wall. Ok To Proceed

    Inspected by Gary Pitzer

Documents