Permit Details

Permit Search

Permit

Remodel

199 SW THURMAN TER
LAKE CITY, FL 32024

Permit #
000056054
Application #
76643
Status Permit Issued
  1. Submitted Jun 8, 2026
  2. Issued Jul 8, 2026
  3. Expires Mar 30, 2027
  4. Completed —

Property

Parcel #
03153-015
Owner
Savage Carla Jean, Smith Jamie L
Acres
0.67
Subdivision
Piccadilly Park Replat Unr
Zoning
RSF-2
Flood zone
X
District
3

Permit

Status
Permit Issued
Septic release
Not yet released
Related permit
—

Job Details

Finished floor requirement
Fema map number
12023C0381D
Type of Structure
House
Commercial or Residential?
Residential
Description of the work being performed:
Demo and build back garage that was damaged during Hurricane Helene.
Building Code Construction Type
V
Building Code Element
B
Building Code Occupancy Types
Residential
Occupancy Use Title
GARAGE
Building Code Edition
2023 Florida Building Code 8th Edition and 2020 National Electrical Code
Service Amps
200

Status & Review History

  1. Application pending.
  2. Application submitted by applicant.
  3. City of Lake City Utilities Notified.
  4. Application Status Update Notification
  5. Product Approval Code Specifications Form was not accepted.
  6. Application Status Update Notification
  7. Application Status Update Notification
  8. Application Status Update Notification
  9. Application Status Update Notification
  10. Application Status Update Notification
  11. Permit Issued

Contractors

  • Roger Whiddon

    Whiddon Construction Co. Inc

    License
    CRC1328025
    Title
    Residential Contractor
    Role
    Contractor

    County License & State License & Liability Insurance & Workers Comp & Employees Workers Comp Expired.

  • Matthew H Burns

    Burns Electrical Services Inc

    License
    EC13006531
    Title
    Electrical Contractor
    Role
    Subcontractor

    Workers Comp Expired.

  1. Sep 23, 2026

    Passed: Building - Roof Decking

    Inspected by Gary Pitzer

  2. Sep 23, 2026

    Passed: Building - Wall Sheathing

    Inspected by Gary Pitzer

  3. Sep 23, 2026

    Passed: Building - Strapping

    Inspected by Gary Pitzer

  4. Sep 23, 2026

    Passed: Building - Framing

    Framing Complete With Doors And Windows Anchored And Sealed, Underlayment On And House Wrap

    Inspected by Gary Pitzer

  5. Oct 1, 2026

    Passed: Electrical - 2nd Rough-In

    Inspected by Matt Forsyth