Permit Details

Permit Search

Permit

New Residential Construction

139 SW GUINEVERE WAY
LAKE CITY, FL 32024

Permit #
000055823
Application #
76033
Status Permit Issued
  1. Submitted May 27, 2026
  2. Issued Jun 4, 2026
  3. Expires Mar 28, 2027
  4. Completed —

Property

Parcel #
03099-227
Owner
John Norris Construction Llc,
Acres
0.50
Subdivision
Stonehenge Phase 2
Zoning
RSF-2
Flood zone
X
District
3

Permit

Status
Permit Issued
Septic release
Released
Related permit
—

Job Details

Elevation regulation
Engineers Elevation Letter
Finished floor requirement
99.77'
Requirement needed
Slab Inspection
Document needed is
Surveyor letter (FFE)
Document receieved
Yes
Fema map number
12023C0293D
This is the construction of a
Single Family Dwelling
Setbacks Front
25'
Setback Side 1
10'
Setback Side 2
10'
Setbacks Rear
15'
Stories
1
Heated Area (Sqft)
1716
Total Area (Sqft)
2588
Building Height
17
Building Code Construction Type
V
Building Code Element
B
Building Code Occupancy Types
Residential
Occupancy Use Title
SINGLE FAMILY DWELLING
Building Code Edition
2023 Florida Building Code 8th Edition and 2020 National Electrical Code
Septic# (00-0000) or (X00-000)
26-0373
Sealed roof decking options. (Must select one option per FBC 2023 8th Edition)
two layers of felt underlayment comply ASTM 0226 Type II or ASTM D4869 Type Ill or IV, or two layers of a synthetic underlayment meeting the performance requirements specified, lapped and fastened as specified.
Service Amps
200

Status & Review History

  1. Application pending.
  2. Application is within the City of Lake City service area
  3. Application Status Update Notification
  4. Recorded Notice of Commencement was not accepted.
  5. Recorded Notice of Commencement was not accepted.
  6. Application Status Update Notification
  7. Application Status Update Notification
  8. Application Status Update Notification
  9. Submitted by building department on applicant's behalf
  10. City of Lake City Utilities Notified.
  11. Application Status Update Notification
  12. Permit Issued

Contractors

  • Sara E Gresham

    John Norris Construction, Llc

    License
    CRC1331978
    Title
    Cert. Residential
    Role
    Contractor
  • Everton D Ruddock

    D&s Lighting Inc

    License
    EC13003800
    Title
    Electrical Contractor
    Role
    Subcontractor
  • Jan R Touchton

    Touchton's Heating & Air Conditioning Inc

    License
    CAC058747
    Title
    Cert. A/c Class “a”
    Role
    Subcontractor
  • Don C Bills Sr

    Hometown Plumbing Services Llc

    License
    CFC1428890
    Title
    Plumbing Contractor
    Role
    Subcontractor
  • Mary C Johnson

    Rcra Johnson Roofing,inc.

    License
    CCC1330073
    Title
    Roofing Contractor
    Role
    Subcontractor
  1. Jun 15, 2026

    Passed: Plumbing/Gas - 1st Underground Rough–In

    Inspected by Matt Forsyth

  2. Jun 17, 2026

    Rescheduled 6/22/2026:Building - Monolithic Slab

    Needed To Reschedule.

    Inspected by Nanderson

  3. Jun 22, 2026

    Cancelled: Building - Monolithic Slab

    Inspected by Mforsyth

  4. Jun 24, 2026

    Passed: Building - Monolithic Slab

    Ffe After Pour

    Inspected by Matt Forsyth

  5. Jul 23, 2026

    Passed: Building - Wall Sheathing

    Inspected by Matt Forsyth

  6. Jul 30, 2026

    Passed: Electrical - Temporary Power Service

    Inspected by Christian Allen

  7. Aug 3, 2026

    Release to power company

    Temp Power

    Inspected by Mgarber

  8. Aug 25, 2026

    Passed: Electrical - 2nd Rough-In

    Inspected by Matt Forsyth

  9. Aug 25, 2026

    Passed: Plumbing/Gas - Tub Set/Shower Pan

    Tub Holding Water No Leaks

    Inspected by Matt Forsyth

  10. Aug 25, 2026

    Passed: Mechanical - Rough In

    Inspected by Matt Forsyth

  11. Aug 25, 2026

    Passed: Plumbing/Gas - 2nd Rough-In

    Inspected by Matt Forsyth

  12. Aug 25, 2026

    Passed: Building - Ext Strapping/Wall Sheathing

    Inspected by Matt Forsyth

  13. Aug 25, 2026

    Passed: Building - Framing

    Inspected by Matt Forsyth

  14. Aug 31, 2026

    Passed: Building - Insulation

    Inspected by Matt Forsyth

  15. Sep 24, 2026

    Failed: Electrical - Permanent Power

    Need Picture Of Service Entrance Pipe

    Inspected by Matt Forsyth

  16. Sep 29, 2026

    Passed: Electrical - Permanent Power

    Underground Race Way Completed Cannot Release Power Until Driveway Permit Has Final Inspection--- Final Drive Rec'd, Ok To Release Power-- 10.7.26 Mg

    Inspected by Gary Pitzer

  17. Oct 7, 2026

    Release to power company

    Inspected by Mgarber

  18. Oct 21, 2026

    Septic Release Inspection

    Inspected by Health Dept

Documents