Permit Details

Permit Search

Permit

Mobile Home

4786 SW OLD WIRE RD
FORT WHITE, FL 32038

Permit #
000055740
Application #
76299
Status Completed
  1. Submitted May 13, 2026
  2. Issued May 27, 2026
  3. Expires Dec 28, 2026
  4. Completed Jul 7, 2026

Property

Parcel #
03755-104
Owner
Jenkins Bufford Earl
Acres
4.00
Subdivision
Columbia South
Zoning
A-3
Flood zone
X
District
4

Permit

Status
Completed
Septic release
Released
Related permit
—

Job Details

Elevation regulation
Minimum Requirement
Finished floor requirement
FFE OF HOME SHALL BE 32” ABOVE ADJACENT GROUND OF ENTIRE PERIMETER OF FOUNDATION
Requirement needed
By Final Inspection
Document needed is
Upload Photos
Document receieved
No
Fema map number
12023C0395C
Mobile Home is a:
Double Wide
Year Built
2026
Width (Ft.In)
28
Length (Ft.In)
64
Driveway access to home:
Existing Drive
Installation Decal #
130406
Septic #
26-0413
Setbacks Front
30'
Setback Side 1
25'
Setbacks Rear
25'
Setback Side 2
25'
Are you applying for a 5 year temporary permit?
No
Serial #
Fl261-000-H-A10-6499AB
Wind Zone?
2
Residential or Commercial Use?
Residential
Service Amps
200
How many of bedrooms does this home have?
3
How many bathrooms does this home have?
2

Status & Review History

  1. Application pending.
  2. Application Status Update Notification
  3. Application Status Update Notification
  4. Application Status Update Notification
  5. Submitted by building department on applicant's behalf
  6. Permit Issued

Contractors

  • Malik Williams

    Mjw Mobile Home Movers Llc

    License
    IH1153065
    Title
    Mh Installer (ih)
    Role
    Contractor
  • Ronald E Bonds Sr

    Style Crest Inc

    License
    CAC1817658
    Title
    Class "b" A/c Contractor
    Role
    Subcontractor

    County License & State License Expired.

Inspections

  1. May 19, 2026

    Septic Release Inspection

    Inspected by Health Dept

  2. Jun 15, 2026

    Failed: Mobile Home - Mobile Home Set-Up Final

    Old Mobile Home Has Been Removed Electric Needs Work On Panel No Dead Front Open Wiring Also Need Ac Unit Installed

    Inspected by Troy Crews

  3. Jun 29, 2026

    Failed: Mobile Home - Mobile Home Set-Up Final

    Temporary Wiring Coming Out Of Panel Needs To Be Removed And Plugged With Knockout Plugs

    Inspected by Troy Crews

  4. Jun 29, 2026

    Passed: Engineering - Setbacks

    Inspected by Troy Crews

  5. Jul 1, 2026

    Passed: Mobile Home - Mobile Home Set-Up Final

    *old Mobile Home Has Been Removed, Temporary Electrical Wiring Has Been Removed *all Requirements Met To Release Co-- 7.7.26 Mg

    Inspected by Troy Crews

  6. Jul 1, 2026

    Release to power company

    Inspected by Troy Crews

  7. Jul 1, 2026

    Passed: Engineering - Setbacks

    Inspected by Troy Crews