Permit Details

Permit Search

Permit

Roof Replacement or Repair

411 SW SEDGEFIELD LN
FORT WHITE, FL 32038

Permit #
000055498
Application #
75764
Status Completed
  1. Submitted Apr 3, 2026
  2. Issued Apr 15, 2026
  3. Expires Feb 2, 2027
  4. Completed Aug 6, 2026

Property

Parcel #
03767-119
Owner
Galbraith Paul David, Galbraith Emelyn David
Acres
5.00
Subdivision
Sedgefield Phase 1
Zoning
A-3
Flood zone
X
District
4

Permit

Status
Completed
Septic release
N/A
Related permit
—

Job Details

Finished floor requirement
Fema map number
12023C0480C
Type Roofing Job
Replacement - Tear off Existing and Replace
Further Job Details (Explain if decking is being replaced and or Repairs are being done.)
Tear off existing asphalt shingles, inspect modular roof decking, replace damaged decking as needed, install synthetic underlayment, drip edge, flashing, and new asphalt shingles per Florida code.
Type of structure
Mobile Home
Commercial or Residential
Residential
Roof Area (for this job) Sq Ft
2260.42
No. of Stories
1
Roof Pitch
4:12 or Greater
Is the existing roof being removed?
Yes
Type of New Roofing Product
Asphalt Shingles
Florida Product Approval Number
FL10124
Product Manufacturer
GAF
Product Description
Architectural asphalt shingles - GAF Timberline HD
Building Code Edition
2023 Florida Building Code 8th Edition and 2020 National Electrical Code
Sealed roof decking options: (Must select an option.)
a minimum 4-inch wide strip of selfadhering polymer-modified bitumen complying with ASTM D1970 or a minimum 3 ¾ - inch wide strip of selfadhering flexible flashing tape complying with AAMA 711, applied over all joints in the roof decking. A felt underlayment complying with ASTM D226 Type II, ASTM D4869 Type Ill or IV, or ASTM D6757, or a synthetic underlayment meeting the performance requirements specified, is required to be applied over the strips/tape over the entire roof.
Ventilation:
Off-ridge Vent
Flashing:
Replace All
Drip Edge:
Replace All
Valley Treatment:
New Metal
Any cable and/or race-way wiring located on or within the roof assembly?
No

Status & Review History

  1. Application pending.
  2. Application submitted by applicant.
  3. Application Status Update Notification
  4. Land Owner Affidavit was not accepted.
  5. Recorded Notice of Commencement was not accepted.
  6. Application Status Update Notification
  7. Application Status Update Notification
  8. Permit Issued

Contractors

This is an owner-builder project.

Inspections

  1. May 15, 2026

    Passed: Re-Roof - In Progress

    Inspected by Troy Crews

  2. Jul 13, 2026

    Passed: Re-Roof - Roof Pictures Review

    Inspected by Christian Allen

  3. Aug 6, 2026

    Rescheduled 8/6/2026:Re-Roof - Final

    Inspected by Tcrews

  4. Aug 6, 2026

    Passed: Re-Roof - Final

    Owner Builder Shingle Roof Installed Over Original Deck That Had Repairs

    Inspected by Gary Pitzer

Documents