Permit Details

Permit Search

Permit

Roof Replacement or Repair

295 SW FANTASY GLN
LAKE CITY, FL 32024

Permit #
000055293
Application #
75645
Status Completed
  1. Submitted Mar 23, 2026
  2. Issued Mar 23, 2026
  3. Expires Oct 26, 2026
  4. Completed Apr 29, 2026

Property

Parcel #
03025-110
Owner
Wampole Earl W,
Acres
1.10
Subdivision
Meadow Vista
Zoning
RR
Flood zone
X
District
3

Permit

Status
Completed
Septic release
N/A
Related permit
—

Job Details

Finished floor requirement
Fema map number
12023C0289D
Type Roofing Job
Replacement - Tear off Existing and Replace
Further Job Details (Explain if decking is being replaced and or Repairs are being done.)
Tear off existing and replace with Architectural Shingles. Inspect decking for any deteriorating areas and replace. Feltbuster underlayment
Type of structure
House
Commercial or Residential
Residential
Roof Area (for this job) Sq Ft
36
No. of Stories
1
Roof Pitch
4:12 or Greater
Is the existing roof being removed?
Yes
Type of New Roofing Product
Asphalt Shingles
Florida Product Approval Number
FL10124.1
Product Manufacturer
GAF
Product Description
Timberline UHDZ shingles
Building Code Edition
2023 Florida Building Code 8th Edition and 2020 National Electrical Code
Sealed roof decking options: (Must select an option.)
two layers of felt underlayment comply ASTM 0226 Type II or ASTM D4869 Type Ill or IV, or two layers of a synthetic underlayment meeting the performance requirements specified, lapped and fastened as specified.
Ventilation:
Ridge Vent
Flashing:
Use Existing
Drip Edge:
Replace All
Valley Treatment:
New Metal
Any cable and/or race-way wiring located on or within the roof assembly?
No

Status & Review History

  1. Application pending.
  2. Application submitted by applicant.
  3. Permit Issued

Contractors

  • Barry D Joye

    Energy Roofing Tech Se Llc (dba) Energy Roofing Companies

    License
    CCC1329523
    Title
    Roofing Contractor
    Role
    Contractor

    County License & State License & Workers Comp Expired.

Inspections

  1. Apr 6, 2026

    Failed: Re-Roof - In Progress

    Work Not Started Please Reschedule

    Inspected by Matt Forsyth

  2. Apr 14, 2026

    Passed: Re-Roof - In Progress

    Inspected by Matt Forsyth

  3. Apr 23, 2026

    Passed: Re-Roof - Roof Affidavit Review

    Inspected by Matt Forsyth

  4. Apr 23, 2026

    Failed: Re-Roof - Roof Pictures Review

    No Ridge Vent Pictures

    Inspected by Matt Forsyth

  5. Apr 28, 2026

    Rescheduled 4/28/2026:Re-Roof - Roof Pictures Review

    Inspected by Tcrews

  6. Apr 28, 2026

    Passed: Re-Roof - Roof Pictures Review

    Inspected by Matt Forsyth

  7. Apr 29, 2026

    Passed: Re-Roof - Final

    Inspected by Troy Crews