Permit Information

New Residential Construction Permit

Address 401 NW NOEGEL RD
LAKE CITY, FL 32055
Parcel #: 02398-301
Acres:4.89
Owner:Spates Maurice, Spates Cassandra
Subdivision:Fairfield Estates
Zoning:A-3
Flood Zone:X
District:3
Application #:74781
Permit #: 000055232
Related Permit:
Submitted:Tuesday, March 10, 2026
Issued:Friday, March 13, 2026
Expires:Saturday, November 7, 2026
Completed:
Status: Permit Issued
Septic Release? No

Notes

*MFE = 1' ABOVE THE ROAD *FINAL SEPTIC REQUIRED PRIOR TO RELEASE OF POWER *ASSESSMENTS OWED @ PERM POWER *BLOWER DOOR & FINAL TERMITE REQUIRED PRIOR TO RELEASE OF CO

Job Details

Elevation regulation Minimum Requirement
Finished floor requirement One foot above the road
Fema map number 12023C0260C
This is the construction of a Single Family Dwelling
Setbacks Front 30'
Setback Side 1 25'
Setback Side 2 25'
Setbacks Rear 25'
Stories 1
Heated Area (Sqft) 2412
Total Area (Sqft) 3774
Building Height 22
Building Code Construction Type V
Building Code Element B
Building Code Occupancy Types Residential
Occupancy Use Title single family dwelling
Building Code Edition 2023 Florida Building Code 8th Edition and 2020 National Electrical Code
Septic# (00-0000) or (X00-000) 26-0153
Sealed roof decking options. (Must select one option per FBC 2023 8th Edition) a minimum 4-inch wide strip of selfadhering polymer-modified bitumen complying with ASTM D1970 or a minimum 3 ¾ - inch wide strip of selfadhering flexible flashing tape complying with AAMA 711, applied over all joints in the roof decking. A felt underlayment complying with ASTM D226 Type II, ASTM D4869 Type Ill or IV, or ASTM D6757, or a synthetic underlayment meeting the performance requirements specified, is required to be applied over the strips/tape over the entire roof.
Service Amps 200

Review Notes

1/13/2026 Application pending.
1/13/2026 Application Status Update Notification
1/21/2026 Application Status Update Notification
1/22/2026 Application Status Update Notification
2/6/2026 Application Status Update Notification
2/9/2026 Application Status Update Notification
2/11/2026 Application Status Update Notification
2/18/2026 Application Status Update Notification
2/20/2026 Application Status Update Notification
3/2/2026 Application Status Update Notification
3/10/2026 Submitted by building department on applicant's behalf
3/10/2026 Application Status Update Notification
3/13/2026 Permit Issued

Contractors

Name / Business License Title Role
Ronnie Edenfield
Scci Inc
CBC1267457 Cert. Building Contractor
Donald Davis
High Springs Electric Inc
EC0002306 Electrical Contractor Subcontractor
Donald R Davis
High Springs Electric Inc
CAC1815367 Class B A/c Subcontractor
Ralph W Laverdure
Rwl Roofing Llc
CCC1328590 Roofing Contractor Subcontractor
Don C Bills Sr
Hometown Plumbing Services Llc
CFC1428890 Plumbing Contractor Contractor

Inspections

Inspection Notes Performed By Date
Passed: Building - Footer Matt Forsyth 3/13/2026
Passed: Electrical - Footer Steel & Grounding Matt Forsyth 3/13/2026
Passed: Plumbing/Gas - 1st Underground Rough–In Waste Lines Only Troy Crews 4/9/2026
Passed: Building - Slab Matt Forsyth 4/20/2026
Passed: Building - Wall Sheathing Masonry Wall. ,steel Inspection Ports Clean Matt Forsyth 5/11/2026

Contact Us

Building Department

Office Hours

Monday-Friday
8:00 A.M. - 4:30 P.M.

Contact Information

Phone: 386-758-1008
Fax: 386-758-2160

Email: bldginfo@columbiacountyfla.com

Location

135 NE Hernando Ave.
Lake City, FL 32055 (opens in new window)

Mailing Address

P.O. Box 1529
Lake City, FL 32056-1529

Public Records

Public records policy and fees

Board of County Commissioners
Tel. (386) 758-1326
Fax: (386) 758-2182
Email: publicrecords@columbiacountyfla.com

Mailing Address:
P.O. Box 1529
Lake City, FL 32056-1529

Citizen Feedback

Let us know how we're doing

ADA Accessibility

Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the Columbia County ADA Coordinator at (386) 758-3344. You may also email that office at hr@columbiacountyfla.com and provide a brief description of the inaccessible feature.

Columbia County strives to provide reasonable accommodations to help people with disabilities have an equal opportunity to participate in our public meetings. Please notify our ADA Coordinator at least 48 hours prior to the public meeting by calling (386) 758-3344.