Passed: Engineering - Initial Driveway
Inspection Notes: The County Doesn’t Have A Detail For A Pipe Extension. But Can Connect To Adjacent Parcel By Cutting Off Miterd End And Placing 18 Inch Corrugated Metal Pipe With Band 24 Feet Minimum Length With The Standard Concrete Mitered End With 4 Inches Limerock Minimal For Cover
Inspected by Smith, Blake