Permit Information

New Residential Construction Permit

Address 9732 SW TUSTENUGGEE AVE
LAKE CITY, FL 32024
Parcel #: 09613-005
Acres:4.47
Owner:Mabile Paul H, Mabile Madeline A
Subdivision:
Zoning:A-3
Flood Zone:X
District:4
Application #:74720
Permit #: 000055053
Related Permit:
Submitted:Thursday, February 12, 2026
Issued:Thursday, February 19, 2026
Expires:Saturday, November 7, 2026
Completed:
Status: Permit Issued
Septic Release? Yes

Notes

*MFE = 12" ABOVE THE ADJACENT GROUND FOR THE ENTIRE PERIMETER OF THE FOUNDATION, INSPECTOR TO VERIFY *FINAL SEPTIC REQUIRED PRIOR TO RELEASE OF POWER *BLOWER DOOR & FINAL TERMITE REQUIRED PRIOR TO RELEASE OF CO REINSPECT ELECTRIC AND HVAC DEFECTS AT TIME OF INSULATION, BUILDER IS AWARE OF THESE ISSUES

Job Details

Elevation regulation Engineers Elevation Letter
Finished floor requirement 12" above adjacent ground for entire perimeter
Fema map number 12023C0395C
This is the construction of a Single Family Dwelling
Setbacks Front 30'
Setback Side 1 30'
Setback Side 2 25'
Setbacks Rear 25'
Stories 1
Heated Area (Sqft) 1617
Total Area (Sqft) 2472
Building Height 15
Building Code Construction Type V
Building Code Element B
Building Code Occupancy Types Residential
Occupancy Use Title single family dwelling
Building Code Edition 2023 Florida Building Code 8th Edition and 2020 National Electrical Code
Septic# (00-0000) or (X00-000) 26-0112
Sealed roof decking options. (Must select one option per FBC 2023 8th Edition) two layers of felt underlayment comply ASTM 0226 Type II or ASTM D4869 Type Ill or IV, or two layers of a synthetic underlayment meeting the performance requirements specified, lapped and fastened as specified.
Service Amps 200

Review Notes

1/6/2026 Application pending.
1/7/2026 Application Status Update Notification
1/20/2026 Application Status Update Notification
1/22/2026 Application Status Update Notification
1/23/2026 Application Status Update Notification
2/4/2026 Application Status Update Notification
2/9/2026 Application Status Update Notification
2/12/2026 Submitted by building department on applicant's behalf
2/17/2026 Application Status Update Notification
2/17/2026 Application Status Update Notification
2/18/2026 Application Status Update Notification
2/19/2026 Application Status Update Notification
2/19/2026 Application Status Update Notification
2/19/2026 Permit Issued

Contractors

Name / Business License Title Role
Oscar Gray
Dependable Heating A/c & Electrical Contractor
EC0001471 Electrical Contractor Subcontractor
Oscar H Gray
Dependable Heating A/c & Electrical Contractor
CAC057649 Class A A/c Subcontractor
John D Williams
John Williams Plumbing Inc
CFC056961 Plumbing Contractor Subcontractor
Bradley E Franks
Bradley Franks Construction, Llc
CGC1535564 Cert. General Contractor

Inspections

Inspection Notes Performed By Date
Septic Release Inspection Health Dept 2/24/2026
Cancelled: Building - Footer Tcrews 2/26/2026
Cancelled: Engineering - Setbacks Tcrews 2/26/2026
Cancelled: Electrical - Footer Steel & Grounding Tcrews 2/26/2026
Passed: Engineering - Setbacks Gary Pitzer 2/26/2026
Passed: Electrical - Footer Steel & Grounding Gary Pitzer 2/26/2026
Passed: Building - Footer Gary Pitzer 2/26/2026
Passed: Plumbing/Gas - 1st Underground Rough–In Dvw And Waterlines Under Preasure Gary Pitzer 3/11/2026
Failed: Building - Slab Will Need Photos Of Rebar Around Perimeter Gary Pitzer 3/12/2026
Rescheduled 4/17/2026:Building - Roof Decking Gpitzer 4/16/2026
Rescheduled 4/17/2026:Building - Wall Sheathing Gpitzer 4/16/2026
Passed: Building - Wall Sheathing Gary Pitzer 4/17/2026
Passed: Building - Roof Decking Gary Pitzer 4/17/2026
Passed: Building - Framing Gary Pitzer 5/5/2026
Passed: Plumbing/Gas - 2nd Rough-In Gary Pitzer 5/5/2026
Failed: Mechanical - Rough In How Are Air Ducts To Be Sealed At Drywall? We Will Reinspect With Insulation Gary Pitzer 5/5/2026
Failed: Electrical - 2nd Rough-In Unapproved Wiring In Under Slab Conduit. We Can Reinspect This At Insulation Gary Pitzer 5/5/2026
Passed: Building - Insulation Troy Crews 5/11/2026

Contact Us

Building Department

Office Hours

Monday-Friday
8:00 A.M. - 4:30 P.M.

Contact Information

Phone: 386-758-1008
Fax: 386-758-2160

Email: bldginfo@columbiacountyfla.com

Location

135 NE Hernando Ave.
Lake City, FL 32055 (opens in new window)

Mailing Address

P.O. Box 1529
Lake City, FL 32056-1529

Public Records

Public records policy and fees

Board of County Commissioners
Tel. (386) 758-1326
Fax: (386) 758-2182
Email: publicrecords@columbiacountyfla.com

Mailing Address:
P.O. Box 1529
Lake City, FL 32056-1529

Citizen Feedback

Let us know how we're doing

ADA Accessibility

Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the Columbia County ADA Coordinator at (386) 758-3344. You may also email that office at hr@columbiacountyfla.com and provide a brief description of the inaccessible feature.

Columbia County strives to provide reasonable accommodations to help people with disabilities have an equal opportunity to participate in our public meetings. Please notify our ADA Coordinator at least 48 hours prior to the public meeting by calling (386) 758-3344.