Permit Details

Permit Search

Permit

Modular Building - Residential or Commercial

394 SW SONOMA WAY
FORT WHITE, FL 32038

Permit #
000054939
Application #
74879
Status Completed
  1. Submitted Jan 29, 2026
  2. Issued Feb 3, 2026
  3. Expires Oct 20, 2026
  4. Completed Apr 24, 2026

Property

Parcel #
04066-009
Owner
Perrault Tim Robert,
Acres
4.00
Subdivision
Quail Ridge
Zoning
A-3
Flood zone
X
District
2

Permit

Status
Completed
Septic release
Released
Related permit
—

Job Details

Elevation regulation
Minimum Requirement
Finished floor requirement
One foot above the road
Fema map number
12023C0495C
Setbacks Front
30'
Setback Side 1
25'
Setback Side 2
25'
Setbacks Rear
25'
Stories
1
Heated Area (Sqft)
2854
Total Area (Sqft)
3040
Building Code Occupancy Types
Residential
Occupancy Use Title
modular home
Building Code Edition
2023 Florida Building Code 8th Edition and 2020 National Electrical Code
Septic# (00-0000) or (X00-000)
25-0971
Modular frame type
On frame
Use Type:
Residential
Service Amps
200

Status & Review History

  1. Application pending.
  2. Application Status Update Notification
  3. Owner and Contractor Signature Page was not accepted.
  4. Application Status Update Notification
  5. Submitted by building department on applicant's behalf
  6. Application Status Update Notification
  7. Submitted by building department on applicant's behalf
  8. Permit Issued

Contractors

  • Glenn Whittington

    Whittington Electric Inc

    License
    EC13002957
    Title
    Electrical Contractor
    Role
    Subcontractor
  • Timothy D Shatto

    Shatto Heating & Air, Inc.

    License
    CAC057875
    Title
    A/c Class B
    Role
    Subcontractor
  • Letcher F Worley Iii

    Worley Construction & Associates Inc

    License
    CGC060228
    Title
    Cert. General
    Role
    Contractor
  • Kyle Johnson

    Florida Mfg Foundations Llc

    License
    IH1126657
    Title
    Mh (dih) Dealer/installer
    Role
    Subcontractor

Inspections

  1. Jan 22, 2026

    Septic Release Inspection

    Inspected by Health Dept

  2. Feb 18, 2026

    Passed: Modular - Setbacks

    Inspected by Gary Pitzer

  3. Feb 18, 2026

    Passed: Modular - Footer

    #5 Rebars Under Walls Per Drawing, Wired And On Chairs

    Inspected by Gary Pitzer

  4. Apr 23, 2026

    Passed: Modular - Permanent Power & Final

    Old Home Removed *all Requirements Met To Release Co-- 4.24.26 Mg

    Inspected by Christian Allen

  5. Apr 23, 2026

    Release to power company

    Inspected by Christian Allen

Documents