Permit Information

New Residential Construction Permit

Address 3961 SW WATSON ST
FORT WHITE, FL 32038
Parcel #: 03734-004
Acres:14.47
Owner:Pittman Chad H, Pittman Tiffani
Subdivision:
Zoning:ESA-2
Flood Zone:X
District:2
Application #:74892
Permit #: 000054891
Related Permit:
Submitted:Friday, January 23, 2026
Issued:Tuesday, January 27, 2026
Expires:Monday, November 2, 2026
Completed:
Status: Permit Issued
Septic Release? No

Notes

*MFE = 1' ABOVE THE ROAD *FINAL SEPTIC REQUIRED PRIOR TO RELEASE OF POWER *ASSESSMENTS OWED @ PERM POWER *BLOWER DOOR AND FINAL TERMITE REQUIRED PRIOR TO RELEASE OF CO

Job Details

Finished floor requirement
Fema map number 12023C0401C
What is the power service for? Storage Building
Other job details: Existing Agriculture Storage Building
Power Company Clay Electric
Septic # (00-0000) or (X00-000) x24-036
Electrical Code Edition 2020 National Electrical Code
Number of requested AMPS for electrical service: 200
Is the power service? New Power Service
Residential or Commercial? Residential

Review Notes

1/23/2026 Application pending.
1/23/2026 Application Status Update Notification
1/23/2026 Submitted by building department on applicant's behalf
1/23/2026 Application Status Update Notification
1/23/2026 Application Status Update Notification
1/26/2026 Application Status Update Notification
1/27/2026 Permit Issued

Contractors

Name / Business License Title Role
Brian T Giebeig
Trent Giebeig Construction,inc.
Liability Insurance Expired.
CRC1330693 Residential Contractor Contractor
Derrick L Williams
D L Williams Heating & Cooling Llc
CAC1816913 Class "b" A/c Contractor Subcontractor
Kenneth R Roche
Ken Roche Plumbing Inc Dba Plumbing Now
CFC1426527 Plumbing Contractor Subcontractor
Everton D Ruddock
D&s Lighting Inc
EC13003800 Electrical Contractor Subcontractor

Inspections

Inspection Notes Performed By Date
Passed: Building - Footer Bond Wire Matt Forsyth 2/2/2026
Passed: Engineering - Setbacks Matt Forsyth 2/2/2026
Passed: Electrical - Temporary Power Service Matt Forsyth 2/2/2026
Release to power company Temp Release Ewilliams 2/12/2026
Passed: Plumbing/Gas - 1st Underground Rough–In Waste Pipe Matt Forsyth 2/16/2026
Passed: Electrical - 1st Underground Rough–In Matt Forsyth 2/20/2026
Passed: Building - Slab Matt Forsyth 2/20/2026
Passed: Building - Wall Sheathing Matt Forsyth 3/16/2026
Passed: Building - Roof Decking Matt Forsyth 3/16/2026
Passed: Building - Ext Strapping/Wall Sheathing Posts And All Headers Matt Forsyth 4/28/2026
Passed: Building - Framing Matt Forsyth 4/28/2026
Passed: Mechanical - Rough In Fresh Air Duct Noted On Fireplace Matt Forsyth 4/28/2026
Passed: Plumbing/Gas - 2nd Rough-In Matt Forsyth 4/28/2026
Passed: Plumbing/Gas - Tub Set/Shower Pan Roll In Shower Matt Forsyth 4/28/2026
Passed: Electrical - 2nd Rough-In Matt Forsyth 4/28/2026
Passed: Building - Insulation Matt Forsyth 5/6/2026

Documents

File Name Date File Size

Contact Us

Building Department

Office Hours

Monday-Friday
8:00 A.M. - 4:30 P.M.

Contact Information

Phone: 386-758-1008
Fax: 386-758-2160

Email: bldginfo@columbiacountyfla.com

Location

135 NE Hernando Ave.
Lake City, FL 32055 (opens in new window)

Mailing Address

P.O. Box 1529
Lake City, FL 32056-1529

Public Records

Public records policy and fees

Board of County Commissioners
Tel. (386) 758-1326
Fax: (386) 758-2182
Email: publicrecords@columbiacountyfla.com

Mailing Address:
P.O. Box 1529
Lake City, FL 32056-1529

Citizen Feedback

Let us know how we're doing

ADA Accessibility

Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the Columbia County ADA Coordinator at (386) 758-3344. You may also email that office at hr@columbiacountyfla.com and provide a brief description of the inaccessible feature.

Columbia County strives to provide reasonable accommodations to help people with disabilities have an equal opportunity to participate in our public meetings. Please notify our ADA Coordinator at least 48 hours prior to the public meeting by calling (386) 758-3344.