Permit Details

Permit Search

Permit

New Residential Construction

285 SW HERMITAGE GLN
HIGH SPRINGS, FL 32643

Permit #
000054636
Application #
74030
Status Completed
  1. Submitted Oct 28, 2025
  2. Issued Dec 8, 2025
  3. Expires Mar 13, 2027
  4. Completed Sep 24, 2026

Property

Parcel #
10039-104
Owner
Beville Ryan Christopher,
Acres
5.00
Subdivision
Hermitage
Zoning
A-3
Flood zone
X
District
4

Permit

Status
Completed
Septic release
Released
Related permit
—

Job Details

Elevation regulation
Minimum Requirement
Finished floor requirement
One foot above the road
Fema map number
12023C0551C
This is the construction of a
Single Family Dwelling
Setbacks Front
30'
Setback Side 1
25'
Setback Side 2
25'
Setbacks Rear
25'
Stories
2
Heated Area (Sqft)
4912
Total Area (Sqft)
6312
Building Code Construction Type
V
Building Code Element
B
Building Code Occupancy Types
Residential
Occupancy Use Title
SINGLE FAMILY DWELLING
Building Code Edition
2023 Florida Building Code 8th Edition and 2020 National Electrical Code
Septic# (00-0000) or (X00-000)
25-0788
Sealed roof decking options. (Must select one option per FBC 2023 8th Edition)
two layers of felt underlayment comply ASTM 0226 Type II or ASTM D4869 Type Ill or IV, or two layers of a synthetic underlayment meeting the performance requirements specified, lapped and fastened as specified.

Status & Review History

  1. Application pending.
  2. Point Review - Pre-submittal Review Notes
  3. Point Review - Pre-submittal Review Notes
  4. Application Status Update Notification
  5. Application Status Update Notification
  6. Application Status Update Notification
  7. Application Status Update Notification
  8. Permit Issued

Contractors

  • Jerry A Lerner

    Lerner Luxury Properties Llc

    License
    CBC015604
    Title
    Building Contractor
    Role
    Contractor

    County License & State License Expired.

  • Paul K Coleman

    Colemans Plumbing Inc.

    License
    CFC1425624
    Title
    Certified Plumbing
    Role
    Subcontractor

    County License & State License & Employees Workers Comp Expired.

  • Benjamin T Keeler

    Keeler Roofing, Llc

    License
    CCC1330509
    Title
    Cert. Roofing
    Role
    Subcontractor
  • Robert M Bounds

    Bounds Heating & Air Inc

    License
    CAC057642
    Title
    Class A A/c
    Role
    Subcontractor
  • Ryan C Beville

    Rbi Electrical Contracting Llc

    License
    EC13004236
    Title
    Electrical Contractor
    Role
    Subcontractor
  • Benjamin T Keeler

    Keeler Roofing, Llc

    License
    CCC1330509
    Title
    Cert. Roofing
    Role
    Subcontractor

Inspections

  1. Dec 9, 2025

    Passed: Building - Footer

    Inspected by Christian Allen

  2. Dec 9, 2025

    Passed: Engineering - Setbacks

    Inspected by Christian Allen

  3. Dec 11, 2025

    Passed: Electrical - Temporary Power Service

    Inspected by Christian Allen

  4. Dec 16, 2025

    Release to power company

    Inspected by Ewilliams

  5. Dec 19, 2025

    Passed: Plumbing/Gas - 1st Underground Rough–In

    Inspected by Christian Allen

  6. Dec 23, 2025

    Passed: Building - Slab

    Inspected by Christian Allen

  7. Feb 19, 2026

    Passed: Building - Wall Sheathing

    Inspected by Christian Allen

  8. Feb 19, 2026

    Passed: Building - Ext Strapping/Wall Sheathing

    Inspected by Christian Allen

  9. Feb 19, 2026

    Passed: Building - Roof Decking

    Inspected by Christian Allen

  10. Apr 7, 2026

    Passed: Building - Framing

    Inspected by Christian Allen

  11. Apr 7, 2026

    Passed: Plumbing/Gas - 2nd Rough-In

    Inspected by Christian Allen

  12. Apr 7, 2026

    Passed: Plumbing/Gas - Tub Set/Shower Pan

    Inspected by Christian Allen

  13. Apr 7, 2026

    Passed: Electrical - 2nd Rough-In

    Inspected by Christian Allen

  14. Apr 7, 2026

    Passed: Mechanical - Rough In

    Inspected by Christian Allen

  15. Apr 17, 2026

    Passed: Building - Insulation

    Inspected by Christian Allen

  16. May 22, 2026

    Passed: Electrical - Permanent Power

    Pending Septic Release

    Inspected by Christian Allen

  17. Jun 1, 2026

    Release to power company

    Rec'd Final Septic

    Inspected by Ewilliams

  18. Jun 1, 2026

    Septic Release Inspection

    Inspected by Health Dept

  19. Sep 14, 2026

    Passed: Building - Final

    *gas Is Not Connected To Water Heater Final Pressure Test And Startup Should Be Done By Gas Provider *all Requirements Met To Release Co-- 9.24.26 Mg

    Inspected by Troy Crews

  20. Requested

    Electrical - Temporary Power Service

    Awaiting inspection

  21. Requested

    Electrical - Temporary Power Service

    Awaiting inspection

  22. Requested

    Plumbing/Gas - 1st Underground Rough–In

    Awaiting inspection

  23. Requested

    Plumbing/Gas - 1st Underground Rough–In

    Awaiting inspection

  24. Requested

    Plumbing/Gas - 1st Underground Rough–In

    Awaiting inspection

Documents