Permit Details

Permit Search

Permit

Roof Replacement or Repair

3117 SE COUNTY ROAD 245
LAKE CITY, FL 32025

Permit #
000054631
Application #
74474
Status Completed
  1. Submitted Dec 5, 2025
  2. Issued Dec 5, 2025
  3. Expires Jun 16, 2026
  4. Completed Dec 18, 2025

Property

Parcel #
08348-000
Owner
Cieslik Carol S
Acres
3.96
Subdivision
—
Zoning
A-3
Flood zone
X
District
4

Permit

Status
Completed
Septic release
N/A
Related permit
—

Job Details

Finished floor requirement
Fema map number
12023C0315C
Type Roofing Job
Re-Cover - New Material over Existing
Further Job Details (Explain if decking is being replaced and or Repairs are being done.)
Dry in over existing shingles, install 1x4 purlins, install 29 ga galvalum metal
Type of structure
House
Commercial or Residential
Residential
Roof Area (for this job) Sq Ft
800
No. of Stories
1
Roof Pitch
2:12 to 4:12
Is the existing roof being removed?
No
Explain if not removing the existing roofing material?
roof over existing shingles with 1x4 purlins and 29 ga galvalum
Type of New Roofing Product
Metal
Florida Product Approval Number
36904-R10
Other Roofing Product Type Not Listed
na
Product Manufacturer
Tri County Metals
Product Description
29 Ga Galvalum
Building Code Edition
2023 Florida Building Code 8th Edition and 2020 National Electrical Code
Sealed roof decking options: (Must select an option.)
Other (explain)
Sealed roof decking explanation for other option.
dry in over existing shingles
Ventilation:
Ridge Vent
Flashing:
Repair Existing
Drip Edge:
Replace All
Valley Treatment:
Use Existing
Any cable and/or race-way wiring located on or within the roof assembly?
No

Status & Review History

  1. Application pending.
  2. City of Lake City Utilities Notified.
  3. Submitted by building department on applicant's behalf
  4. City of Lake City Utilities Notified.
  5. Application Status Update Notification
  6. Permit Issued

Contractors

  • Charlotte J Johnson

    Johnson & Johnson Roofing, Inc.

    License
    CCC057237
    Title
    Roofing Contractor
    Role
    Contractor

Inspections

  1. Dec 17, 2025

    Cancelled: Re-Roof - In Progress

    Inspected by Nanderson

  2. Dec 17, 2025

    Passed: Re-Roof - In Progress

    Furring Strips For New Metal Roof Covering

    Inspected by Gary Pitzer

  3. Dec 17, 2025

    Passed: Re-Roof - Roof Pictures Review

    Inspected by Gary Pitzer

  4. Dec 17, 2025

    Passed: Re-Roof - Roof Affidavit Review

    Inspected by Gary Pitzer

  5. Dec 18, 2025

    Passed: Re-Roof - Final

    Inspected by Christian Allen

  6. Dec 18, 2025

    Passed: Re-Roof - Final

    Metal Roof Overlay

    Inspected by Gary Pitzer