Roof Replacement or Repair
Permit
| Application #: | 74334 |
| Permit #: |
000054570 |
| Related Permit: |
|
| Submitted: | Monday, November 24, 2025 |
| Issued: | Tuesday, November 25, 2025 |
| Expires: | Tuesday, December 16, 2025 |
| Completed: | Tuesday, December 16, 2025 |
| Status: |
Completed |
| Septic Release? |
N/A |
Job Details
| Finished floor requirement |
|
| Fema map number |
12023C0290D |
| Type Roofing Job |
Replacement - Tear off Existing and Replace |
| Type of structure |
House |
| Commercial or Residential |
Residential |
| Roof Area (for this job) Sq Ft |
40 |
| No. of Stories |
1 |
| Roof Pitch |
4:12 or Greater |
| Is the existing roof being removed? |
Yes |
| Type of New Roofing Product |
Asphalt Shingles |
| Florida Product Approval Number |
10674r19 |
| Product Manufacturer |
owens corning |
| Product Description |
Asphalt Shingles |
| Building Code Edition |
2023 Florida Building Code 8th Edition and 2020 National Electrical Code |
| Sealed roof decking options: (Must select an option.) |
a minimum 4-inch wide strip of selfadhering polymer-modified bitumen complying with ASTM D1970 or a minimum 3 ¾ - inch wide strip of selfadhering flexible flashing tape complying with AAMA 711, applied over all joints in the roof decking. A felt underlayment complying with ASTM D226 Type II, ASTM D4869 Type Ill or IV, or ASTM D6757, or a synthetic underlayment meeting the performance requirements specified, is required to be applied over the strips/tape over the entire roof. |
| Ventilation: |
Off-ridge Vent |
| Flashing: |
Use Existing |
| Drip Edge: |
Replace All |
| Valley Treatment: |
New Metal |
Review Notes
| 11/20/2025 |
Application pending. |
| 11/24/2025 |
City of Lake City Utilities Notified. |
| 11/24/2025 |
Application Status Update Notification |
| 11/24/2025 |
Application Status Update Notification |
| 11/24/2025 |
Submitted by building department on applicant's behalf |
| 11/24/2025 |
City of Lake City Utilities Notified. |
| 11/24/2025 |
Application Status Update Notification |
| 11/25/2025 |
Permit Issued |
Contractors
| Name / Business |
License |
Title |
Role |
David J Pabst Whittle Roofing Company, Inc.
|
CCC1326372 |
Cert. Roofing |
Contractor |
Inspections
| Inspection |
Notes |
Performed By |
Date |
| Passed: Re-Roof - In Progress |
|
Matt Forsyth |
12/2/2025 |
| Failed: Re-Roof - Roof Pictures Review |
No Off Ridge Vent Pictures |
Matt Forsyth |
12/4/2025 |
| Passed: Re-Roof - Roof Pictures Review |
|
Matt Forsyth |
12/15/2025 |
| Passed: Re-Roof - In Progress |
Roof Is Complete |
Matt Forsyth |
12/16/2025 |
| Rescheduled 12/16/2025:Re-Roof - Final |
|
Tcrews |
12/16/2025 |
| Passed: Re-Roof - Final |
|
Christian Allen |
12/16/2025 |