Permit Information

New Residential Construction Permit

Address 316 SW CABOOSE DR
FORT WHITE, FL 32038
Parcel #: 04059-124
Acres:0.51
Owner:Terry Craig A, Terry Lisa G
Subdivision:Fort White Station
Zoning:
Flood Zone:X
District:2
Application #:72444
Permit #: 000054141
Related Permit:
Submitted:Wednesday, July 30, 2025
Issued:Wednesday, September 24, 2025
Expires:Tuesday, May 26, 2026
Completed:Tuesday, May 26, 2026
Status: Completed
Septic Release? Yes

Notes

*MFE = 1' ABOVE THE ROAD *SEPTIC FINAL REQUIRED PRIOR TO RELEASE OF POWER *ASSESSMENTS OWED AT PERM POWER *BLOWER DOOR AND TERMITE FINAL REQUIRED PRIOR TO CO

Job Details

Elevation regulation Minimum Requirement
Finished floor requirement One foot above the road
Fema map number 12023C0490C
This is the construction of a Single Family Dwelling
Setbacks Front 25'
Setback Side 1 10'
Setback Side 2 10'
Setbacks Rear 15'
Stories 1
Heated Area (Sqft) 1300
Total Area (Sqft) 2003
Building Height 12
Building Code Construction Type V
Building Code Element B
Building Code Occupancy Types Residential
Occupancy Use Title single family dwelling
Building Code Edition 2023 Florida Building Code 8th Edition and 2020 National Electrical Code
Septic# (00-0000) or (X00-000) 25-0670
Sealed roof decking options. (Must select one option per FBC 2023 8th Edition) two layers of felt underlayment comply ASTM 0226 Type II or ASTM D4869 Type Ill or IV, or two layers of a synthetic underlayment meeting the performance requirements specified, lapped and fastened as specified.
Service Amps 200

Review Notes

7/30/2025 Application pending.
8/1/2025 Point Review - Pre-submittal Review Notes
8/3/2025 Point Review - Pre-submittal Review Notes
9/5/2025 Point Review - Pre-submittal Review Notes
9/11/2025 Point Review - Pre-submittal Review Notes
9/11/2025 Point Review - Pre-submittal Review Notes
9/15/2025 Point Review - Pre-submittal Review Notes
9/16/2025 Point Review - Pre-submittal Review Notes
9/17/2025 Point Review - Pre-submittal Review Notes
9/17/2025 Point Review - Pre-submittal Review Notes
9/21/2025 Point Review - Pre-submittal Review Notes
9/23/2025 Point Review - Ready for applicant submittal
9/23/2025 Application submitted by applicant.
9/23/2025 Application submitted by applicant.
9/23/2025 Application submitted by applicant.
9/23/2025 Application submitted by applicant.
9/23/2025 Point Review - Reviewed
9/23/2025 Zoning Review - Reviewed
9/23/2025 Plan Review - Sent to plan review
9/23/2025 Plan Review - Plumbing Approved
9/23/2025 Plan Review - Mechanical Approved
9/23/2025 Plan Review - Electrical Approved
9/23/2025 Plan Review - Building Approved
9/23/2025 Plan Review - Reviewed
9/23/2025 Final Review - Sent for final review
9/23/2025 Final Review - Reviewed
9/23/2025 Final Review - Payment Needed
9/23/2025 Final Review - Complete
9/24/2025 Permit Issued
3/26/2026 Permit Status Update Notification

Contractors

Name / Business License Title Role
Jeffrey P Bokor
Dwc Contracting Llc
CGC1517145 General Contractor Contractor
James Butler Jr
Butler Plumbing Of Gainesville Inc
CFC057960 Plumbing Contractor Subcontractor
Jeffrey Bokor
Dwc Contracting Llc
CCC1329756 Roofing Contractor Subcontractor
Ryan C Beville
Rbi Electrical Contracting Llc
EC13004236 Electrical Contractor Subcontractor
Samuel L Roberts
Air Ducks Inc
Liability Insurance & Workers Comp & Employees Workers Comp Expired.
CAC1817288 Class "b" A/c Subcontractor

Inspections

Inspection Notes Performed By Date
Passed: Electrical - Temporary Power Service Anthony Aslan 9/24/2025
Passed: Plumbing/Gas - 1st Underground Rough–In Inspection Performed Anthony Aslan 9/24/2025
Passed: Building - Monolithic Slab Anthony Aslan 9/24/2025
Passed: Engineering - Setbacks Appears Within Setbacks Anthony Aslan 9/24/2025
Release to power company Temp Service Ewilliams 9/30/2025
Passed: Building - Ext Strapping/Wall Sheathing Christian Allen 10/10/2025
Passed: Building - Roof Decking Christian Allen 10/10/2025
Passed: Electrical - 2nd Rough-In Anthony Aslan 10/16/2025
Passed: Building - Framing Christian Allen 10/27/2025
Passed: Plumbing/Gas - Tub Set/Shower Pan Christian Allen 10/27/2025
Passed: Plumbing/Gas - 2nd Rough-In Install Nail Plate At Guest Bathroom Toilet Water Line Stud Will Check At Next Inspection Christian Allen 10/27/2025
Passed: Mechanical - Rough In Christian Allen 10/27/2025
Passed: Building - Insulation Matt Forsyth 12/17/2025
Passed: Electrical - Permanent Power Septic And Driveway Releases Needed Matt Forsyth 12/17/2025
Septic Release Inspection Health Dept 1/12/2026
Release to power company Rec'd Septic Final - Drive Not County Maintained Ewilliams 1/16/2026
Passed: Building - Final *appears To Meet Elevation Requirements Per Inspector, All Requirements Met To Release Co-- 5.26.26 Mg Christian Allen 5/6/2026

Documents

File Name Date File Size
Certificate Of Occupancy 20260526.pdf 2026.05.26 24.78kB
Blower Door Test Results 20260415 161638.pdf 2026.04.15 2.19MB
Termite Treatment - Final 20260415 132718.pdf 2026.04.15 287.45kB
Power Release-release To Power Company 20260116.pdf 2026.01.26 11.44kB
Setbacks000.pdf 2025.12.08 52.47kB
Power Release-release To Power Company 20250930.pdf 2025.09.30 11.02kB
Original Permit 20250924.pdf 2025.09.30 32.52kB
Application.pdf 2025.09.30 34.41kB
Inspections Checklist.pdf 2025.09.30 117.08kB
Approved Structural Bokor.pdf 2025.09.23 8.36MB
Approved Truss Plans Bokor.pdf 2025.09.23 1.21MB
Town Of Fort White Compliance Letter.pdf 2025.09.23 76.38kB
Town Of Fort White Compliance Letter (not Signed By Clerk).pdf 2025.09.17 76.38kB
Recorded Notice Of Commencement 20250917 153726.pdf 2025.09.17 180.41kB
Terry Eh 25-0670.pdf 2025.09.16 651.73kB
Srwmd Enhanced Snapshot 72444.pdf 2025.09.02 632.85kB
Structural Engineering And Wind Load Calculations.pdf 2025.09.02 8.32MB
Product Approval Code Specifications Form 20250821 104629.jpg 2025.08.29 273.67kB
Floodplain Notice To Owner 20250806 154935.jpg 2025.08.29 334.54kB
Proposed Site Plan 20250821 104629.pdf 2025.08.29 90.91kB
Residential Checklist 20250821 104629.pdf 2025.08.21 1.06MB
Architectural Plans 20250819 122202.pdf 2025.08.19 8.32MB
Truss Engineering 20250812 150032.pdf 2025.08.12 1.16MB
Energy Code Forms.pdf 2025.08.04 91.15kB
Manual J Forms 20250730 111510.pdf 2025.08.04 108.35kB
911 Address Form 20250730 094629.pdf 2025.08.04 217.45kB
Subcontractor Form 20250730 101120.pdf 2025.08.04 219.71kB
Recorded Deed 20250730 094630.pdf 2025.08.04 219.42kB
Owner And Contractor Signature Page 20250730 094629.pdf 2025.08.04 357.12kB
Property Appraiser Parcel Details Printed Page 20250730 094629.pdf 2025.08.04 264.91kB

Contact Us

Building Department

Office Hours

Monday-Friday
8:00 A.M. - 4:30 P.M.

Contact Information

Phone: 386-758-1008
Fax: 386-758-2160

Email: bldginfo@columbiacountyfla.com

Location

135 NE Hernando Ave.
Lake City, FL 32055 (opens in new window)

Mailing Address

P.O. Box 1529
Lake City, FL 32056-1529

Public Records

Public records policy and fees

Board of County Commissioners
Tel. (386) 758-1326
Fax: (386) 758-2182
Email: publicrecords@columbiacountyfla.com

Mailing Address:
P.O. Box 1529
Lake City, FL 32056-1529

Citizen Feedback

Let us know how we're doing

ADA Accessibility

Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the Columbia County ADA Coordinator at (386) 758-3344. You may also email that office at hr@columbiacountyfla.com and provide a brief description of the inaccessible feature.

Columbia County strives to provide reasonable accommodations to help people with disabilities have an equal opportunity to participate in our public meetings. Please notify our ADA Coordinator at least 48 hours prior to the public meeting by calling (386) 758-3344.