Permit Details

Permit Search

Permit

New Residential Construction

903 SW MANDIBA DR
LAKE CITY, FL 32024

Permit #
000053948
Application #
71939
Status Completed
  1. Submitted Jul 8, 2025
  2. Issued Aug 29, 2025
  3. Expires Dec 21, 2026
  4. Completed Jun 25, 2026

Property

Parcel #
09280-130
Owner
Humphrey Ronald L, Humphrey Cheryl
Acres
1.01
Subdivision
Oaks Of Lake City Phase 1
Zoning
PRRD
Flood zone
X
District
5

Permit

Status
Completed
Septic release
Released
Related permit
—

Job Details

Elevation regulation
Subdivision Plat
Finished floor requirement
87'
Requirement needed
By Nailing Inspection
Document needed is
NA
Document receieved
Yes
Fema map number
12023C0395C
This is the construction of a
Single Family Dwelling
Setbacks Front
30'
Setback Side 1
15'
Setback Side 2
15'
Setbacks Rear
15'
Stories
0
Heated Area (Sqft)
3823
Total Area (Sqft)
6284
Building Height
24
Building Code Construction Type
V
Building Code Element
B
Building Code Occupancy Types
Residential
Occupancy Use Title
SINGLE FAMILY DWELLING
Building Code Edition
2023 Florida Building Code 8th Edition and 2020 National Electrical Code
Septic# (00-0000) or (X00-000)
25-0567
Sealed roof decking options. (Must select one option per FBC 2023 8th Edition)
two layers of felt underlayment comply ASTM 0226 Type II or ASTM D4869 Type Ill or IV, or two layers of a synthetic underlayment meeting the performance requirements specified, lapped and fastened as specified.
Service Amps
200

Status & Review History

  1. Application pending.
  2. Point Review - Pre-submittal Review Notes
  3. Point Review - Pre-submittal Review Notes
  4. Point Review - Pre-submittal Review Notes
  5. Point Review - Pre-submittal Review Notes
  6. Point Review - Pre-submittal Review Notes
  7. Point Review - Pre-submittal Review Notes
  8. Point Review - Pre-submittal Review Notes
  9. Point Review - Pre-submittal Review Notes
  10. Point Review - Ready for applicant submittal
  11. Application submitted by applicant.
  12. Point Review - Reviewed
  13. Zoning Review - Reviewed
  14. Plan Review - Plumbing Approved
  15. Plan Review - Mechanical Approved
  16. Plan Review - Electrical Approved
  17. Plan Review - Building Approved
  18. Plan Review - Reviewed
  19. Final Review - Processing
  20. Final Review - Reviewed
  21. Final Review - Payment Needed
  22. Permit Issued
  23. Final Review - Complete

Contractors

  • Isaiah Cully

    Ic Construction Llc

    License
    CBC1259655
    Title
    Building Contractor
    Role
    Contractor
  • Cody Barrs

    Barrs Plumbing Inc

    License
    CFC1427145
    Title
    Plumbing Contractor
    Role
    Subcontractor
  • Tyler M Turner

    Tmt Roofing Llc

    License
    CCC1330410
    Title
    Cert Roofing
    Role
    Subcontractor
  • Everton D Ruddock

    D&s Lighting Inc

    License
    EC13003800
    Title
    Electrical Contractor
    Role
    Subcontractor
  • Clinton G Wilson

    Wilson Heat & Air Inc

    License
    CAC057886
    Title
    Class B A/c
    Role
    Subcontractor

Inspections

  1. Sep 5, 2025

    Passed: Building - Footer

    Inspected by Troy Crews

  2. Oct 1, 2025

    Passed: Electrical - Temporary Power Service

    Inspected by Gary Pitzer

  3. Oct 1, 2025

    Passed: Plumbing/Gas - 1st Underground Rough–In

    Dwv Only, Also Electric Conduits

    Inspected by Gary Pitzer

  4. Oct 7, 2025

    Passed: Building - Monolithic Slab

    Inspected by Gary Pitzer

  5. Oct 7, 2025

    Passed: Building - Slab

    Steel In Footer And Aroun Perimeter Wire And On Chairs,plastic And Tape

    Inspected by Gary Pitzer

  6. Nov 18, 2025

    Release to power company

    Temp Service

    Inspected by Ewilliams

  7. Nov 24, 2025

    Passed: Building - Roof Decking

    Inspected by Gary Pitzer

  8. Nov 24, 2025

    Passed: Building - Wall Sheathing

    Inspected by Gary Pitzer

  9. Jan 23, 2026

    Passed: Plumbing/Gas - 2nd Rough-In

    Inspected by Troy Crews

  10. Jan 23, 2026

    Passed: Electrical - 2nd Rough-In

    Inspected by Troy Crews

  11. Jan 23, 2026

    Passed: Building - Ext Strapping/Wall Sheathing

    Inspected by Troy Crews

  12. Jan 23, 2026

    Failed: Building - Framing

    Exterior Wall Of Upstairs Dormer Needs To Be Attached To Floor Framing

    Inspected by Troy Crews

  13. Jan 23, 2026

    Passed: Mechanical - Rough In

    Inspected by Troy Crews

  14. Feb 16, 2026

    Failed: Building - Insulation

    Need To Address Framing Issue Prior To Insulation Approval

    Inspected by Troy Crews

  15. Feb 16, 2026

    Passed: Building - Framing

    Inspected by Gary Pitzer

  16. Feb 16, 2026

    Passed: Building - Insulation

    Inspected by Gary Pitzer

  17. Mar 31, 2026

    Septic Release Inspection

    Inspected by Health Dept

  18. May 20, 2026

    Passed: Electrical - Permanent Power

    Inspected by Troy Crews

  19. May 20, 2026

    Release to power company

    Inspected by Troy Crews

  20. Jun 24, 2026

    Passed: Building - Final

    *all Requirements Met To Release Co-- 6.25.26 Mg

    Inspected by Troy Crews

Documents