Permit Details

Permit Search

Permit

Right-of-Way Access/Driveway

SW WEIRSDALE PL
,

Permit #
000053758
Application #
72161
Status Completed
  1. Submitted Jul 18, 2025
  2. Issued Aug 2, 2025
  3. Expires Dec 22, 2028
  4. Completed Dec 23, 2025

Property

Parcel #
00367-154
Owner
Poirier Charles R, Poirier Katharine E
Acres
5.01
Subdivision
Pine Mount Heights
Zoning
—
Flood zone
—
District
—

Permit

Status
Completed
Septic release
N/A
Related permit
—

Job Details

Finished floor requirement
Standards
Culvert installation shall conform to the approved site plan standards
Requirements
An 18” storm pipe of approved material is required with a minimum length of 32 feet. 4” Concrete Pads shall be located on each mitered end section, and shall be 5’ wide by 7’ long
Status
Permanent
Type of connection for access road
Driveway & Sidewalk;Drainage
Type of construction of property
Site Built Home
If the type of construction is not listed, please describe below
putting in an additional driveway access ENTRANCE [ Property currently has 1 additional existing entrance ]
If the type of construction will contain units or lots, please enter the number of units or lots below
0
Normal vehicle usage:
Large trucks with trailers
Side Drain required
Yes
Side Drain Size (diameter in inches)
18
Study Required
No
Estimated Number of Vehicle trips per day
1
Is the access for commercial or residential use?
Residential
County Road Type
Paved

Status & Review History

  1. Application submitted by applicant.
  2. Pending Public Works Application Approval
  3. Application submitted by applicant.
  4. Pending Public Works Application Approval
  5. Application submitted by applicant.
  6. Pending Public Works Application Approval
  7. Final Review - Processing
  8. Application Approved by Public Works
  9. Final Review - Payment Needed
  10. Pending initial driveway inspection
  11. Permit Issued

Contractors

This is an owner-builder project.

Inspections

  1. Jul 18, 2025

    Passed: Engineering - ROW Access/Driveway connects to county maintained road

    Inspected by Chad Williams

  2. Jul 24, 2025

    Failed: Engineering - Verify existing driveway

    Resident Is Requesting Second Driveway, Initial Driveway Inspection Required. Observed Asphalt Roadway Damaged At Location Second Driveway, Repairs Will Be Needed.

    Inspected by Beach, Garrett

  3. Aug 1, 2025

    Passed: Engineering - Initial Driveway

    Inspected by Beach, Garrett

  4. Dec 23, 2025

    Passed: Engineering - Final Driveway

    Inspected by Beach, Garrett